Detection of human immunoglobulin in microchip and conventional capillary electrophoresis with contactless conductivity measurements

被引:78
作者
Abad-Villar, EM
Tanyanyiwa, J
Fernández-Abedul, MT
Costa-García, A
Hauser, PC [1 ]
机构
[1] Univ Basel, Dept Chem, Basel, Switzerland
[2] Univ Oviedo, Dept Quim Fis & Analit, Asturias, Spain
关键词
D O I
10.1021/ac0346656
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The detection of human immunoglobulin M (IgM) was performed using capacitively coupled contactless conductivity detection (CCD) in electrophoresis carried out in conventional capillaries as well as on glass and poly(methyl methacrylate) (PMMA) microdevices. Also achieved was the analyses of IgG (an anti-human IgM) and the complex formed in the reaction between the two immunoreagents. It is demonstrated that CCD is a powerful tool suitable not only for the detection of antibodies but also for monitoring an immunological interaction. Conductivity measurements allow the direct determination of immunoreagents, and it is advantageous, since no labels are required. The immunoglobulin IgM has been taken as model analyte. The reproducibility of the analytical signal (RSD = 1%), sensitivity and limits of detection obtained for IgM (0.15 ng/mL in conventional capillaries and 34 ng/mL in microchips) are comparable to those previously obtained with amperometric detection. The immunological reaction was performed either in conventional microtiter plates as used in ELISA or in situ on the glass chip.
引用
收藏
页码:1282 / 1288
页数:7
相关论文
共 31 条
[1]   The use of gold bands for flow immunoelectrochemical devices [J].
Abad-Villar, EM ;
Fernández-Abedul, MT ;
Costa-García, A .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2003, 377 (02) :267-272
[2]   Gold bands as a suitable surface for enzyme immunoassays [J].
Abad-Villar, EM ;
Fernández-Abedul, MT ;
Costa-García, A .
BIOSENSORS & BIOELECTRONICS, 2002, 17 (09) :797-802
[3]   Competitive immunoassay for recombinant hirudin using capillary electrophoresis with laser-induced fluorescence detection [J].
Ban, E ;
Nam, HS ;
Yoo, YS .
JOURNAL OF CHROMATOGRAPHY A, 2001, 924 (1-2) :337-344
[4]   Determination of allergens in foods [J].
Besler, M .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2001, 20 (11) :662-672
[5]   Electroosmotic flow in composite microchannels and implications in microcapillary electrophoresis systems [J].
Bianchi, F ;
Wagner, F ;
Hoffmann, P ;
Girault, HH .
ANALYTICAL CHEMISTRY, 2001, 73 (04) :829-836
[6]  
Burtis C.A., 1994, Tietz Textbook of Clinical Chemistry
[7]  
da Silva JAF, 1998, ANAL CHEM, V70, P4339
[8]  
Guijt RM, 2001, ELECTROPHORESIS, V22, P2537, DOI 10.1002/1522-2683(200107)22:12<2537::AID-ELPS2537>3.0.CO
[9]  
2-C
[10]   Capillary electrophoretic enzyme immunoassay with electrochemical detection for thyroxine [J].
He, ZH ;
Jin, WR .
ANALYTICAL BIOCHEMISTRY, 2003, 313 (01) :34-40