Broad-band dielectric spectroscopy of low-permittivity fluids using one measurement cell

被引:37
作者
Folgero, K [1 ]
机构
[1] Stord Haugesund Coll, Dept Engn, N-5500 Haugesund, Norway
[2] Univ Bergen, Dept Phys, N-5007 Bergen, Norway
关键词
coaxial sensor; dielectric spectroscopy; microwave measurements; oil quality; permittivity;
D O I
10.1109/19.744637
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Dielectric spectroscopy is a relevant method for quality characterization of petrochemical products, provided that the permittivity spectra are measured with high precision over a broad frequency range. This paper describes how the permittivity of low-loss liquids such as crude oils can be measured with high precision using a single measurement cell in the broad frequency range 1 kHz to 6 GHz, The use of a single cell ensures that the whole dielectric spectrum is measured under the same conditions, which is an advantage for both on-line acid laboratory applications. The permittivity spectrum is obtained by combining impedance and S-parameter measurements of a coaxial transmission/reflection cell with suitable permittivity calculation methods, The high sensitivity of the system is confirmed by measurements on crude oils and known low-loss liquids.
引用
收藏
页码:881 / 885
页数:5
相关论文
共 17 条
[1]  
Bailey A.E., 1985, MICROWAVE MEASUREMEN
[2]   IMPROVED TECHNIQUE FOR DETERMINING COMPLEX PERMITTIVITY WITH THE TRANSMISSION REFLECTION METHOD [J].
BAKERJARVIS, J ;
VANZURA, EJ ;
KISSICK, WA .
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 1990, 38 (08) :1096-1103
[3]  
BUCKLEY F, 1958, 589 NBS
[4]   Dispersion and absorption in dielectrics I. Alternating current characteristics [J].
Cole, KS ;
Cole, RH .
JOURNAL OF CHEMICAL PHYSICS, 1941, 9 (04) :341-351
[5]   TIME DOMAIN REFLECTION METHODS FOR DIELECTRIC MEASUREMENTS TO GHZ [J].
COLE, RH ;
BERBERIAN, JG ;
MASHIMO, S ;
CHRYSSIKOS, G ;
BURNS, A ;
TOMBARI, E .
JOURNAL OF APPLIED PHYSICS, 1989, 66 (02) :793-802
[6]   TIME DOMAIN REFLECTOMETRY [J].
COLE, RH .
ANNUAL REVIEW OF PHYSICAL CHEMISTRY, 1977, 28 :283-300
[7]   Bilinear calibration of coaxial transmission/reflection cells for permittivity measurement of low-loss liquids [J].
Folgero, K .
MEASUREMENT SCIENCE AND TECHNOLOGY, 1996, 7 (09) :1260-1269
[8]   A BROAD-BAND AND HIGH-SENSITIVITY DIELECTRIC-SPECTROSCOPY MEASUREMENT SYSTEM FOR QUALITY DETERMINATION OF LOW-PERMITTIVITY FLUIDS [J].
FOLGERO, K ;
FRIISO, T ;
HILLAND, J ;
TJOMSLAND, T .
MEASUREMENT SCIENCE AND TECHNOLOGY, 1995, 6 (07) :995-1008
[9]   Complex permittivity of crude oils and solutions of heavy crude oil fractions [J].
Friiso, T ;
Schildberg, Y ;
Rambeau, O ;
Tjomsland, T ;
Fordedal, H ;
Sjoblom, J .
JOURNAL OF DISPERSION SCIENCE AND TECHNOLOGY, 1998, 19 (01) :93-126
[10]  
FRIISO T, IN PRESS ENERGY FUEL