High Accuracy and Wide Temperature Measurement by Non-Contact Speckle Extensometer

被引:4
|
作者
Kobayashi, K. [1 ]
Yamaguchi, I. [1 ]
机构
[1] Toyo Seiki Seisaku Sho Ltd, Tech Dept, Tokyo, Japan
关键词
laser-speckle correlation; low- and high-temperature test; non-contact measurement; tensile test;
D O I
10.1111/j.1475-1305.2008.00550.x
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
A new extensometer that has been developed needs neither markings nor mechanical clips to be attached onto the specimen and is perfectly noncontacting to automatise tensile test. Separate laser beams are incident at the positions where the markings were attached in the conventional extensometer. The spots on the specimen are imaged on a separate charge-coupled device (CCD) to produce a speckle pattern, the displacement of which is detected by real-time digital speckle correlation. Each of the optical systems is installed in a separate movable probe head that is moved under feedback control to nullify the speckle displacement detected. For detecting a small amount of specimen displacement, less than a few millimetres, the optical head is fixed to output speckle displacement. A resolution of 1 mu m was attained by comparison with a linear laser encoder. A larger displacement was detected from displacement of the probe head that cancels the detected speckle displacement by feedback control of the head movement. We also conducted tensile test in a temperature chamber controlled in a range between -40 and 100 degrees C, by placing the probe heads outside a window of the chamber.
引用
收藏
页码:E98 / E103
页数:6
相关论文
共 50 条
  • [21] A framework for non-contact measurement and analysis of NURBS surfaces
    Ristic, M
    Brujic, D
    INTERNATIONAL JOURNAL OF ADVANCED MANUFACTURING TECHNOLOGY, 1998, 14 (03) : 210 - 219
  • [22] Non-contact Measurement Technique for Enzymatic Reaction of Glucokinase
    Staforelli, Juan P.
    Gallardo, Maria J.
    Meza, Pablo
    Torres, Sergio
    Mella, Hector
    Reyes, Claudio
    OPTICAL METHODS IN DEVELOPMENTAL BIOLOGY II, 2014, 8953
  • [23] Simultaneous non-contact measurement of water level and conductivity
    Yin, W.
    Peyton, A. J.
    Zysko, G.
    Denno, R.
    2006 IEEE INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE PROCEEDINGS, VOLS 1-5, 2006, : 2144 - +
  • [24] Non-contact measurement of dynamic stiffness of rotating spindle
    Matsubara, Atsushi
    Sawamura, Ryota
    Asano, Kohei
    Muraki, Toshiyuki
    6TH CIRP INTERNATIONAL CONFERENCE ON HIGH PERFORMANCE CUTTING (HPC2014), 2014, 14 : 484 - 487
  • [25] The Design and Implementation of a Non-contact Laser Measurement System
    ZHANG Ni ZHANG Yunwen LIU Weijun PU Xiongying China Agricultural University BeijingShenyang Institute of Automation Chinese Academy of SciencesShenyangChina
    微计算机信息, 2008, (22) : 7 - 9+162
  • [26] Non-contact Current Measurement in Power Transmission Lines
    Selva, Kruphalan Tamil
    Forsberg, Olof A.
    Merkoulova, Daniel
    Ghasemifard, Fatemeh
    Taylor, Nathaniel
    Norgren, Martin
    SMART GRID TECHNOLOGIES (ICSGT- 2015), 2015, 21 : 498 - 506
  • [27] Non-contact measurement of oil tube thread and the application
    He, FJ
    Cui, XM
    Zhang, YH
    Huang, ZZ
    OPTICAL TECHNOLOGY AND IMAGE PROCESSING FOR FLUIDS AND SOLIDS DIAGNOSTICS 2002, 2002, 5058 : 661 - 665
  • [28] A Non-Contact Measurement System for the Range of Motion of the Hand
    Trieu Pham
    Pathirana, Pubudu N.
    Hieu Trinh
    Fay, Pearse
    SENSORS, 2015, 15 (08): : 18315 - 18333
  • [29] A high-accuracy non-contact online measurement method of the rotor-stator axial gap based on the microwave heterodyne structure
    Niu, Guangyue
    Duan, Fajie
    Liu, Zhibo
    Jiang, Jiajia
    Fu, Xiao
    MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 2021, 150
  • [30] Research for new method for high-precision non-contact measurement of rotate speed
    LIU YAN ZUO CHUNCHENG ZHANG YUMEI LI LIGANGCollege of Mechanical Science and Engineering Jilin UniversityChangchun ShanDong Institute of Business and TechnologyYanTai
    微计算机信息, 2008, (04) : 74 - 76