High Accuracy and Wide Temperature Measurement by Non-Contact Speckle Extensometer

被引:4
|
作者
Kobayashi, K. [1 ]
Yamaguchi, I. [1 ]
机构
[1] Toyo Seiki Seisaku Sho Ltd, Tech Dept, Tokyo, Japan
关键词
laser-speckle correlation; low- and high-temperature test; non-contact measurement; tensile test;
D O I
10.1111/j.1475-1305.2008.00550.x
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
A new extensometer that has been developed needs neither markings nor mechanical clips to be attached onto the specimen and is perfectly noncontacting to automatise tensile test. Separate laser beams are incident at the positions where the markings were attached in the conventional extensometer. The spots on the specimen are imaged on a separate charge-coupled device (CCD) to produce a speckle pattern, the displacement of which is detected by real-time digital speckle correlation. Each of the optical systems is installed in a separate movable probe head that is moved under feedback control to nullify the speckle displacement detected. For detecting a small amount of specimen displacement, less than a few millimetres, the optical head is fixed to output speckle displacement. A resolution of 1 mu m was attained by comparison with a linear laser encoder. A larger displacement was detected from displacement of the probe head that cancels the detected speckle displacement by feedback control of the head movement. We also conducted tensile test in a temperature chamber controlled in a range between -40 and 100 degrees C, by placing the probe heads outside a window of the chamber.
引用
收藏
页码:E98 / E103
页数:6
相关论文
共 50 条
  • [1] A micro sensor for non-contact temperature measurement
    Li, XP
    Chan, WF
    MICROMACHINING AND MICROFABRICATION, 2000, 4230 : 66 - 75
  • [2] Non-contact measurement of contact wire
    Yi Yaxing
    Ye Xuemei
    Li Zhongke
    Yue Kaiduan
    2008 INTERNATIONAL CONFERENCE ON OPTICAL INSTRUMENTS AND TECHNOLOGY: OPTOELECTRONIC MEASUREMENT TECHNOLOGY AND APPLICATIONS, 2009, 7160
  • [3] Design of a non-contact human body temperature measurement system
    Deng, Xiaohong
    Su, Junhong
    FOURTH INTERNATIONAL CONFERENCE ON PHOTONICS AND OPTICAL ENGINEERING, 2021, 11761
  • [4] Non-contact temperature Raman measurement in YSZ and alumina ceramics
    Thapa, Juddha
    Chorpening, Benjamin T.
    Buric, Michael P.
    OXIDE-BASED MATERIALS AND DEVICES IX, 2018, 10533
  • [5] Design of Non-contact measurement System
    Peng, Feng
    Wang, Zhuoer
    Peng, Bin
    Zheng, Liping
    2020 5TH INTERNATIONAL CONFERENCE ON MECHANICAL, CONTROL AND COMPUTER ENGINEERING (ICMCCE 2020), 2020, : 990 - 993
  • [6] Contact and non-contact ultrasonic measurement in the food industry: a review
    Khairi, Mohd Taufiq Mohd
    Ibrahim, Sallehuddin
    Yunus, Mohd Amri Md
    Faramarzi, Mahdi
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2016, 27 (01)
  • [7] Non-contact measurement of revolving body straightness
    Zhang, SX
    Liu, YL
    Liu, WL
    Ran, DG
    Wang, JC
    PROCEEDINGS OF THE INTERNATIONAL SYMPOSIUM ON PRECISION MECHANICAL MEASUREMENT, VOL 4, 2002, : 132 - 136
  • [8] Non-contact Measurement of Plastic Film Thickness
    He Ping
    Liu Chao
    Li Qi
    Cao Shengmei
    2014 33RD CHINESE CONTROL CONFERENCE (CCC), 2014, : 7462 - 7465
  • [9] Design of Non-contact Coordinate Measurement System
    Liu, Jingliang
    Pang, Chunchao
    Fang, Jianguo
    PROCEEDINGS OF THE 2015 6TH INTERNATIONAL CONFERENCE ON MANUFACTURING SCIENCE AND ENGINEERING, 2016, 32 : 1841 - 1844
  • [10] Simple measurement system for non-contact oxygen saturation measurement
    Hino Y.
    Kariya K.
    Maruyama K.
    Tamura H.
    Akimoto T.
    Transactions of Japanese Society for Medical and Biological Engineering, 2019, 57 (06): : 230 - 235