Comparison of total-etch, self-etch, and selective etching techniques on class V composite restorations prepared by Er:YAG laser and bur: a scanning electron microscopy study

被引:4
作者
Ozel, Emre [1 ]
Tuna, Elif Bahar [2 ]
Firatli, Sonmez [3 ]
Firatli, Erhan [4 ]
机构
[1] Kocaeli Univ, Fac Dent, Dept Restorat Dent, TR-41190 Basiskele, Kocaeli, Turkey
[2] Istanbul Univ, Dept Pediat Dent, Fac Dent, Istanbul, Turkey
[3] Istanbul Univ, Dept Orthodont, Fac Dent, Istanbul, Turkey
[4] Istanbul Univ, Dept Periodontol, Fac Dent, Istanbul, Turkey
关键词
class V cavity; Er:YAG laser; microleakage; nanohybrid composite; selective etching technique; ALUMINUM-GARNET LASER; ENAMEL BOND STRENGTHS; CAVITY PREPARATION; CLINICAL-EVALUATION; DENTIN ADHESIVES; DIAMOND BUR; MICROLEAKAGE; SYSTEMS; AGENTS; INTERFACE;
D O I
10.1002/jemt.22735
中图分类号
R602 [外科病理学、解剖学]; R32 [人体形态学];
学科分类号
100101 ;
摘要
The purpose of this study was to compare total-etch, self-etch, and selective etching techniques on the marginal microleakage of Class V composite restorations prepared by Er:YAG laser and bur. Class V cavities prepared on both buccal and lingual surfaces of 30 premolars by Er:YAG laser or bur and divided into six groups. The occlusal margins were in enamel, and the cervical margins were in cementum. Group-1: bur preparation(bp)+Adper Single Bond 2 (ASB) +Filtek Z550 (FZ); Group-2: laser preparation(lp)+(ASB)+(FZ); Group-3: bp+Clearfil S3 Bond Plus (CSBP)+(FZ); Group-4: lp+(CSBP) (FZ); Group-5: bp+acid etching+(CSBP)+(FZ); Group-6: lp+acid etching+ (CSBP) +(FZ). All teeth were stored in distilled water at 37 degrees C for 24 hr, and then thermocycled 1000 times (5-55 degrees C). Five teeth from each group were chosen for the microleakage investigation, and two teeth for the scanning electron microscope evaluation. Teeth which were prepared for the microleakage test were immersed in .5% methylene blue dye for 24 hr. After immersion, the teeth were sectioned and observed under a stereomicroscope for dye penetration. Data were analyzed using Kruskal-Wallis and Mann-Whitney U tests (p<. 05). More microleakage was observed in the cervical regions compared to the occlusal regions in Groups 3, 5, and 6, respectively (p<. 05). There is no statistically significant difference in Groups 1, 2, and 4, in terms of cervical regions versus occlusal regions (p>. 05). No significant differences were observed among any groups in terms of occlusal and cervical surfaces, separately (p>. 05). Different etching techniques did not influence microleakage of Class V restorations prepared by Er: YAG laser and bur.
引用
收藏
页码:998 / 1004
页数:7
相关论文
共 14 条
[1]   Effect of different parameters of Er:YAG laser irradiations on class V composite restorations: A scanning electron microscopy study [J].
Ozel, Emre ;
Tuna, Elif Bahar ;
Firatli, Sonmez ;
Firatli, Erhan .
SCANNING, 2016, 38 (05) :434-441
[2]   The effects of cavity-filling techniques on microleakage in class II resin restorations prepared with Er:YAG laser and diamond bur: A scanning electron microscopy study [J].
Ozel, Emre ;
Tuna, Elif Bahar ;
Firatli, Erhan .
SCANNING, 2016, 38 (05) :389-395
[3]   Comparative Evaluation of Microleakage With Total-Etch, Universal (Self-Etch Mode), and Nano Adhesive Systems in Class V Composite Restorations: An In-Vitro Study [J].
Singh, Sarveshwari ;
Bhadauria, Upendra S. ;
Sharma, Apoorva ;
Mathur, Rouble Verma .
CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (10)
[4]   The effects of dental adhesives total etch; self-etch and selective etch application procedures on microleakage in class II composite restorations [J].
Yollar, Mustafa ;
Karaoglanoglu, Serpil ;
Altiparmak, Elif Tugba ;
Oktay, Elif Aybala ;
Aydin, Numan ;
Ersoz, Bilge .
EUROPEAN ORAL RESEARCH, 2023, 57 (03) :151-158
[5]   Marginal adaptation of two-step self-etch versus universal adhesives for Class V restorations: Effect of Er:YAG laser vs. bur prepared cavities [J].
Noerpuspita, Putri ;
Krejci, Ivo ;
Bortolotto, Tissiana .
AMERICAN JOURNAL OF DENTISTRY, 2024, 37 (01) :29-34
[6]   Microleakage and scanning electron microscopy evaluation of all-in-one self-etch adhesives and their respective nanocomposites prepared by erbium:yttrium-aluminum-garnet laser and bur [J].
Korkmaz, Yonca ;
Ozel, Emre ;
Attar, Nuray ;
Bicer, Ceren Ozge ;
Firatli, Erhan .
LASERS IN MEDICAL SCIENCE, 2010, 25 (04) :493-502
[7]   Microleakage and scanning electron microscopy evaluation of all-in-one self-etch adhesives and their respective nanocomposites prepared by erbium:yttrium–aluminum–garnet laser and bur [J].
Yonca Korkmaz ;
Emre Ozel ;
Nuray Attar ;
Ceren Ozge Bicer ;
Erhan Firatli .
Lasers in Medical Science, 2010, 25 :493-502
[8]   Microleakage of Self-Etch Adhesive System in Class V Cavities Prepared by Using Er:YAG Laser with Different Pulse Modes [J].
Phanombualert, Jutipond ;
Chimtim, Pijitta ;
Heebthamai, Thitirat ;
Weera-Archakul, Wilawan .
PHOTOMEDICINE AND LASER SURGERY, 2015, 33 (09) :467-472
[9]   A Comparative Study of Microleakage on Dental Surfaces Bonded with Three Self-Etch Adhesive Systems Treated with the Er:YAG Laser and Bur [J].
El Haddar, Youssef Sanhadji ;
Cetik, Sibel ;
Bahrami, Babak ;
Atash, Ramin .
BIOMED RESEARCH INTERNATIONAL, 2016, 2016
[10]   Influence of the LED curing source and selective enamel etching on dentin bond strength of self-etch adhesives in class I composite restorations [J].
Souza-Junior, Eduardo Jose ;
Pimenta Araujo, Cintia Tereza ;
Prieto, Lucia Trazzi ;
Maffei Sartini Paulillo, Luis Alexandre .
LASERS IN MEDICAL SCIENCE, 2012, 27 (06) :1175-1182