A Modified Adaptive Cross Correlation Method for Flow Rate Measurement of High-Water-Cut Oil-Water Flow Using Planar Flowmeter

被引:22
|
作者
Zhang, Xiaokai [1 ]
Sun, Jiangtao [1 ]
Hu, Jinhai [2 ]
Liu, Xiaolei [2 ]
Liu, Xingbin [2 ]
Xie, Ronghua [2 ]
Cai, Bing [2 ]
Sun, Liang [2 ]
Xu, Lijun [1 ]
机构
[1] Beihang Univ, Sch Instrumentat & Optoelect Engn, Beijing 100191, Peoples R China
[2] Daqing Oilfield Co Ltd, Daqing 163453, Peoples R China
关键词
Electrodes; Flowmeters; Perturbation methods; Sensitivity; Electric fields; Time measurement; Resistance; Flow rate; high-water-cut oil-water two-phase flow; modified adaptive (MA) cross correlation; observation window; planar flowmeter; transition time; VELOCITY-MEASUREMENT; ANALYTICAL-MODEL; METER;
D O I
10.1109/TIM.2021.3129485
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This article proposed a modified adaptive (MA) cross correlation method to measure the flow rate of high-water-cut oil-water two-phase flow. It asynchronously commences the acquisitions of the upstream and downstream signals for cross correlation according to the flow rate, enhancing the degree of correlation between them, thus a higher measurement accuracy of transition time can be obtained. By limiting the searching scope of the correlogram's peak value in a transition time-related observation window, the calculation process is kept steady and divergence due to the outliers is effectively avoided. A planar flowmeter is adopted for high-water-cut flow rate measurement, and the advantages in axial resolution and sensitivity are analyzed. Experiments are conducted in 90% water cut oil-water flow in a practical vertical well. Results show that compared to the conventional (C) one, the MA method is capable of fast and reliable capture of the transition time from the upstream to the downstream sensors in a much wider flow rate range, with much lower deviation and a higher degree of correlation. Finally, the flow rates and their uncertainties are calculated from the measured transition time to validate the measurement stability.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Novel Downhole Electromagnetic Flowmeter for Oil-Water Two-Phase Flow in High-Water-Cut Oil-Producing Wells
    Wang, Yanjun
    Li, Haoyu
    Liu, Xingbin
    Zhang, Yuhui
    Xie, Ronghua
    Huang, Chunhui
    Hu, Jinhai
    Deng, Gang
    SENSORS, 2016, 16 (10)
  • [2] Theory and application of ultrasonic cross correlation flowmeter for oil-water flow
    Wang, ZH
    Wang, L
    MULTIPHASE FLOW AND HEAT TRANSFER, 1999, : 342 - 347
  • [3] Ultrasonic method for measuring water holdup of low velocity and high-water-cut oil-water two-phase flow
    An Zhao
    Yun-Feng Han
    Ying-Yu Ren
    Lu-Sheng Zhai
    Ning-De in
    Applied Geophysics, 2016, 13 : 179 - 193
  • [4] Ultrasonic method for measuring water holdup of low velocity and high-water-cut oil-water two-phase flow
    Zhao An
    Han Yun-Feng
    Ren Ying-Yu
    Zhai Lu-Sheng
    Jin Ning-De
    APPLIED GEOPHYSICS, 2016, 13 (01) : 179 - 193
  • [5] Comparison of Transverse With Axial Excitation Modes Cross Correlation Flowmeters in High Water-Cut Oil-Water Flow Measurement
    Zhang, Xiaokai
    Sun, Jiangtao
    Hu, Jinhai
    Suo, Peng
    Liu, Xingbin
    Xie, Ronghua
    Cai, Bing
    Sun, Liang
    Wang, Tao
    Wang, Chenwei
    Xu, Lijun
    IEEE SENSORS JOURNAL, 2023, 23 (03) : 2336 - 2345
  • [6] Volumetric flow rate measurement with capacitive electromagnetic flowmeter in oil-water two-phase flow
    Wang, Baoliang
    Fu, Yongfeng
    Huang, Zhiyao
    Li, Haiqing
    2010 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE I2MTC 2010, PROCEEDINGS, 2010,
  • [7] Oil-water two-phase flow measurement using vortex flowmeter
    Xing, Juan
    Zhang, Tao
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2009, 30 (04): : 882 - 886
  • [8] Water cut measurement of oil-water flow in vertical well by combining total flow rate and the response of a conductance probe
    Chen, Jianjun
    Xu, Lijun
    Cao, Zhang
    Zhang, Wen
    Liu, Xingbin
    Hu, Jinhai
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2015, 26 (09)
  • [9] Application of cross-correlation and calorimetry in measurement of oil-water two phase flow
    He, Anding
    Li, Bin
    Zhou, Fangde
    Huaxue Gongcheng/Chemical Engineering, 2000, 28 (01): : 40 - 43
  • [10] Method of high water-cut oil-water two-phase flow measurement based on phase-isolation
    Yang Y.
    Hu H.
    Ha W.
    Yang B.
    Wang D.