High Performance Simulation Models for ES-STATCOM Based on Modular Multilevel Converters

被引:30
作者
Cupertino, Allan Fagner [1 ,2 ]
Amorim, William Caires Silva [3 ]
Pereira, Heverton Augusto [4 ]
Seleme Junior, Seleme Isaac [5 ]
Chaudhary, Sanjay Kumar [6 ]
Teodorescu, Remus [6 ]
机构
[1] Univ Fed Minas Gerais, Grad Program Elect Engn, BR-31270901 Belo Horizonte, MG, Brazil
[2] Fed Ctr Technol Educ Minas Gerais, Dept Mat Engn, BR-30421169 Belo Horizonte, MG, Brazil
[3] Fed Ctr Technol Educ Minas Gerais, Grad Program Elect Engn, BR-30421169 Belo Horizonte, MG, Brazil
[4] Univ Fed Vicosa, Dept Elect Engn, BR-36570900 Vicosa, MG, Brazil
[5] Univ Fed Minas Gerais, Dept Elect Engn, BR-31270901 Belo Horizonte, MG, Brazil
[6] Aalborg Univ, Dept Energy Technol, DK-9220 Aalborg, Denmark
关键词
Modular multilevel converter; ES-STATCOMs; grid frequency support; battery storage plants; reduced order simulation models;
D O I
10.1109/TEC.2020.2967314
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Due to the high integration of renewable energy, the power systems may become more susceptible to unbalanced grid voltages, grid frequency disturbances, harmonic resonances and others. Therefore, several works have pointed out that the ancillary services provided by the energy storage systems can minimize these issues. The combination of energy storage and static synchronous compensators (ES-STATCOM) has been proposed to reduce the cost. Modular multilevel converters (MMC) are featured as a good solution for ES-STATCOM realization, due to their high efficiency, modularity and inherent fault-tolerant structure. However, the study of the integration of the MMC based ES-STATCOM in a complex power system composed of power electronic converters, transmission system, renewable plants, transformers, etc, leads to a high computational burden. Therefore, this work presents a detailed design and implementation of three efficient simulation models of the MMC ES-STATCOM. The performance of these models compared during a grid frequency support case study by a 100 MVA/33 kV ES-STATCOM. In addition, the performance of these models is evaluated during a battery charging process and a grid symmetrical fault. The models are compared through the following aspects: processing time, normalized integral of absolute error, state-of-charge estimation and active and reactive power dynamic response.
引用
收藏
页码:474 / 483
页数:10
相关论文
共 29 条
[1]   A Computationally Efficient Continuous Model for the Modular Multilevel Converter [J].
Ahmed, Noman ;
Angquist, Lennart ;
Norrga, Staffan ;
Antonopoulos, Antonios ;
Harnefors, Lennart ;
Nee, Hans-Peter .
IEEE JOURNAL OF EMERGING AND SELECTED TOPICS IN POWER ELECTRONICS, 2014, 2 (04) :1139-1148
[2]   Enhanced Equivalent Model of the Modular Multilevel Converter [J].
Ajaei, Firouz Badrkhani ;
Iravani, Reza .
IEEE TRANSACTIONS ON POWER DELIVERY, 2015, 30 (02) :666-673
[3]  
[Anonymous], ESS BATT SAMS SDI
[4]  
[Anonymous], FREQ VOLT SUPP DYN G
[5]  
[Anonymous], P IEEE 8 PEDG APR
[6]  
[Anonymous], 604B457 TB
[7]  
[Anonymous], 2014, 2014 16 EUR C POW EL
[8]  
[Anonymous], DYN EN STOR SYST UK
[9]   Comparison of Detailed Modeling Techniques for MMC Employed on VSC-HVDC Schemes [J].
Beddard, Antony ;
Barnes, Mike ;
Preece, Robin .
IEEE TRANSACTIONS ON POWER DELIVERY, 2015, 30 (02) :579-589
[10]  
Bharadwaj C, 2017, ASIA-PAC POWER ENERG