Reliability of functional gait assessment in patients with Parkinson disease: Interrater and intrarater reliability and internal consistency

被引:10
作者
Yang, Yaqin [1 ]
Wang, Yongjun [1 ]
Zhou, Yanan [1 ]
Chen, Chen [1 ]
Xing, Deli [1 ]
机构
[1] Capital Med Univ, Beijing Tiantan Hosp, Dept Neurol, Beijing, Peoples R China
关键词
assessment; balance; gait; Parkinson disease; reliability; VALIDITY; BALANCE; PERFORMANCE; DISABILITY; PEOPLE; SCALE; INDEX;
D O I
10.1097/MD.0000000000004545
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To determine the reliability of the functional gait assessment (FGA) as a measure of balance and gait in patients with Parkinson disease (PD).This study involved121 inpatients with PD (mean age 61.9 years). The participants were scored using the FGA by 2 raters, and the testing procedure was videotaped. One of the raters re-assessed the same FGA test via review of the videotaped test 4 weeks later.The interrater and intrarater reliability of the total FGA score was found to be excellent, with an intraclass correlation coefficient of 0.99. The reliability of single items of the FGA ranged from 0.49 to 0.99. The internal consistency of the FGA scores was 0.94.The FGA has high inter-rater and intrarater reliability, and internal consistency for evaluating balance and gait disorders in patients with PD.
引用
收藏
页数:5
相关论文
共 22 条
  • [1] [Anonymous], NEUROL REP
  • [2] [Anonymous], NEUROL REP
  • [3] The circumstances of falls among people with Parkinson's disease and the use of Falls Diaries to facilitate reporting
    Ashburn, A.
    Stack, E.
    Ballinger, C.
    Fazakarley, L.
    Fitton, C.
    [J]. DISABILITY AND REHABILITATION, 2008, 30 (16) : 1205 - 1212
  • [4] The Effects of Exercise on Balance in Persons with Parkinson's Disease: A Systematic Review Across the Disability Spectrum
    Dibble, Leland E.
    Addison, Odessa
    Papa, Evan
    [J]. JOURNAL OF NEUROLOGIC PHYSICAL THERAPY, 2009, 33 (01): : 14 - 26
  • [5] REVISED NORMATIVE STANDARDS OF PERFORMANCE OF MEN ON A QUANTITATIVE ATAXIA TEST BATTERY
    FREGLY, AR
    SMITH, MJ
    GRAYBIEL, A
    [J]. ACTA OTO-LARYNGOLOGICA, 1973, 75 (01) : 10 - 16
  • [6] Movement disorder society task force report on the Hoehn and Yahr staging scale: Status and recommendations
    Goetz, CG
    Poewe, W
    Rascol, O
    Sampaio, C
    Stebbins, GT
    Counsell, C
    Giladi, N
    Holloway, RG
    Moore, CG
    Wenning, GK
    Yahr, MD
    Seidl, L
    [J]. MOVEMENT DISORDERS, 2004, 19 (09) : 1020 - 1028
  • [7] Understanding internal consistency reliability estimates: A conceptual primer on coefficient alpha
    Henson, RK
    [J]. MEASUREMENT AND EVALUATION IN COUNSELING AND DEVELOPMENT, 2001, 34 (03) : 177 - 189
  • [8] MEASUREMENT OF OBSERVER AGREEMENT FOR CATEGORICAL DATA
    LANDIS, JR
    KOCH, GG
    [J]. BIOMETRICS, 1977, 33 (01) : 159 - 174
  • [9] Functional Gait Assessment and Balance Evaluation System Test: Reliability, Validity, Sensitivity, and Specificity for Identifying Individuals With Parkinson Disease Who Fall
    Leddy, Abigail L.
    Crowner, Beth E.
    Earhart, Gammon M.
    [J]. PHYSICAL THERAPY, 2011, 91 (01): : 102 - 113