Modeling and Insulation Performance Analysis of Composite Transmission Line Tower Under Lightning Overvoltage

被引:10
|
作者
Huangfu, Youpeng [1 ]
Wang, Shuhong [1 ]
Wang, Guolin [1 ]
Xu, Weijie [1 ]
Zhang, Haijun [1 ]
机构
[1] Xi An Jiao Tong Univ, Fac Elect Engn, State Key Lab Elect Insulat & Power Equipment, Xian 710049, Peoples R China
基金
中国国家自然科学基金;
关键词
Composite transmission line (TL) tower; finite-element method (FEM); lightning overvoltage; multi-conductor transmission line (MTL);
D O I
10.1109/TMAG.2014.2356859
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper, a new non-uniform multiconductor transmission line model combining with lumped circuit elements for a composite transmission line (TL) tower under lightning strokes is established. The metal ground-wire cross arms, the metal tower main body and its bracings are modeled as equivalent horizontal and vertical TLs, respectively. The two grounding ladders are regarded as two parallel-vertical TLs considering their mutual coupling. These distributed TL parameters are calculated by analytic equations. The composite arms are equivalent as lumped capacitances determined by employing 3-D finite-element method. The lightning overvoltage analysis for a 330-kV composite tower is performed by applying the hybrid model. The incident and reflected voltages are calculated. The insulation performance evaluation for the composite tower is discussed in detail.
引用
收藏
页数:4
相关论文
共 50 条
  • [1] Transient Lightning Impulse Performance Analysis for Composite Transmission Line Tower
    Huangfu, Youpeng
    Wang, Shuhong
    Tao, Xi
    IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 2015, 57 (05) : 1103 - 1111
  • [2] The Impact of Transmission Line Modeling on Lightning Overvoltage
    Leon Colqui, Jaimis Sajid
    Ribeiro de Moura, Rodolfo Antonio
    De Oliveira Schroeder, Marco Aurelio
    Pissolato Filho, Jose
    Kurokawa, Sergio
    ENERGIES, 2023, 16 (03)
  • [3] Lightning performance of quadruple circuit transmission line with Voltage 500 kV on the same vertical tower under unbalance insulation
    Su, Fei
    Zhou, Hao
    Zhao, Bincai
    Gaodianya Jishu/High Voltage Engineering, 2012, 38 (09): : 2473 - 2480
  • [5] Effects of transmission line tower grounding improvements on its lightning performance
    Diaz, Luis
    Grange, Francois
    Journet, Sebastien
    Dawalibi, Farid
    2021 35TH INTERNATIONAL CONFERENCE ON LIGHTNING PROTECTION (ICLP) AND XVI INTERNATIONAL SYMPOSIUM ON LIGHTNING PROTECTION (SIPDA), 2021,
  • [6] Tower modeling for lightning analysis of. overhead transmission lines
    Martinez, JA
    Castro-Aranda, F
    2005 IEEE POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS, 1-3, 2005, : 1212 - 1217
  • [7] Lightning overvoltage analysis and calculation of 330kV overhead transmission line
    Zhang Xiubin
    Wen Dingjun
    Sun Yaming
    Chen Honggang
    MECHATRONICS ENGINEERING, COMPUTING AND INFORMATION TECHNOLOGY, 2014, 556-562 : 1588 - 1591
  • [8] An Investigation of Direct Grounding System Effect on Modeling of Lightning and Tower in Transmission Line
    Nugroho, Agung
    Abouzeid, Omar
    Hermawan
    Syakur, Abdul
    Karnoto
    Facta, Mochammad
    2018 5TH INTERNATIONAL CONFERENCE ON INFORMATION TECHNOLOGY, COMPUTER, AND ELECTRICAL ENGINEERING (ICITACEE), 2018, : 272 - 275
  • [9] Calculation of overvoltage on nearby underground metal pipeline due to the lightning strike on UHV AC transmission line tower
    Qi, Lei
    Yuan, Hui
    Wu, Yan
    Cui, Xiang
    ELECTRIC POWER SYSTEMS RESEARCH, 2013, 94 : 54 - 63
  • [10] The Lightning Contingency Probability Analysis on Transmission Tower with Line Arresters Protection
    Kuo, Cheng-Chien
    Chang, Hong-Chan
    Chen, Fu-Hsien
    2013 IEEE PES ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2013,