Comparative analysis of volatile organic compounds of breath and urine for distinguishing patients with liver cirrhosis from healthy controls by using electronic nose and voltammetric electronic tongue

被引:21
作者
Zaim, Omar [1 ,2 ]
Diouf, Alassane [1 ,2 ]
El Bari, Nezha [2 ]
Lagdali, Naoual [3 ]
Benelbarhdadi, Imane [3 ]
Ajana, Fatima Zohra [3 ]
Llobet, Eduard [4 ]
Bouchikhi, Benachir [1 ]
机构
[1] Moulay Ismail Univ Meknes, Fac Sci, Dept Phys, Sensor Elect & Instrumentat Grp, BP 11201, Zitoune, Meknes, Morocco
[2] Moulay Ismail Univ Meknes, Fac Sci, Dept Biol, Biosensors & Nanotechnol Grp, BP 11201, Zitoune 50003, Meknes, Morocco
[3] Mohammed V Univ, Ibn Sina Hosp, Dept Med Gastroenterol C, Rabat, Morocco
[4] Univ Rovira & Virgili, MINOS EMaS, Dept Elect Engn, Microsyst & Nanotechnol Chem Anal, Avinguda Paisos Catalans 26, Tarragona 43007, Spain
关键词
Liver cirrhosis; Volatile organic compounds; Exhaled breath analysis; Urine analysis; Electronic sensing system; Data fusion; TRACE-ELEMENTS; EXHALED BREATH; DATA FUSION; CANCER; DISCRIMINATION; BIOMARKERS; DISEASE; IDENTIFICATION; GENE; ZINC;
D O I
10.1016/j.aca.2021.339028
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Advanced stage detection of liver cirrhosis (LCi) would lead to high mortality rates in patients. Therefore, accurate and non-invasive tools for its early detection are highly needed using human emanations that may reflect this disease. Human breath, along with urine and blood, has long been one of the three main biological media for assessing human health and environmental exposure. The primary objective of this study was to explore the potential of using volatile organic compounds (VOCs) assay of exhaled breath and urine samples for the diagnosis of patients with LCi and healthy controls (HC). For this purpose, we used a hybrid electronic nose (E-nose) combining two sensor families, consisting of an array of five commercial chemical gas sensors and six interdigitated chemical gas sensors based on pristine or metal doped WO3 nanowires for sensing volatile gases in exhaled breath. A voltammetric electronic tongue (VE-tongue), composed of five working electrodes, was dedicated to the analysis of urinary VOCs using cyclic voltammetry as a measurement technique. 54 patients were recruited for this study, comprising 22 patients with LCi, and 32 HC. The two-sensing systems coupled with pattern recognition methods, namely Principal Component Analysis (PCA) and Discriminant Function Analysis (DFA), were trained to classify data clusters associated with the health status of the two groups. The diagnostic performances of the E-nose and VE-tongue systems were studied by using the receiver operating characteristic (ROC) method. The use of the E-nose or the VE-tongue separately, trained with these appropriate classifiers, showed a slight overlap indicating no clear discrimination between LCi patients and HC. To improve the performance of both electronic sensing devices, an emerging strategy, namely a multi-sensor data fusion technique, was proposed as a second aim to overcome this shortcoming. The data fusion approach of the two systems, at a medium level of abstraction, has demonstrated the ability to assess human health and disease status using non-invasive screening tools based on exhaled breath and urinary VOC analysis. This suggests that exhaled breath as well as urinary VOCs are specific to a disease state and could potentially be used as diagnostic methods. (C) 2021 Published by Elsevier B.V.
引用
收藏
页数:12
相关论文
共 71 条
  • [51] Nayak NC, 2013, INDIAN J MED RES, V137, P1029
  • [52] Pfeiffer Ronald F, 2011, Handb Clin Neurol, V100, P681, DOI 10.1016/B978-0-444-52014-2.00049-5
  • [53] A profile of volatile organic compounds in exhaled air as a potential non-invasive biomarker for liver cirrhosis
    Pijls, Kirsten E.
    Smolinska, Agnieszka
    Jonkers, Daisy M. A. E.
    Dallinga, Jan W.
    Masclee, Ad A. M.
    Koek, Ger H.
    van Schooten, Frederik-Jan
    [J]. SCIENTIFIC REPORTS, 2016, 6
  • [54] Rahelic D, 2006, COLLEGIUM ANTROPOL, V30, P523
  • [55] Breath analysis by nanostructured metal oxides as chemo-resistive gas sensors
    Righettoni, Marco
    Amann, Anton
    Pratsinis, Sotiris E.
    [J]. MATERIALS TODAY, 2015, 18 (03) : 163 - 171
  • [56] Volatile Organic Compounds as Biomarkers of Gastrointestinal Diseases and Nutritional Status
    Rondanelli, Mariangela
    Perdoni, Federica
    Infantino, Vittoria
    Faliva, Milena Anna
    Peroni, Gabriella
    Iannello, Giancarlo
    Nichetti, Mara
    Alalwan, Tariq A.
    Perna, Simone
    Cocuzza, Clementina
    [J]. JOURNAL OF ANALYTICAL METHODS IN CHEMISTRY, 2019, 2019
  • [57] Fusion of aroma, FT-IR and UV sensor data based on the Bayesian inference. Application to the discrimination of white grape varieties
    Roussel, S
    Bellon-Maurel, V
    Roger, JM
    Grenier, P
    [J]. CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2003, 65 (02) : 209 - 219
  • [58] Analysis of apples varieties -: comparison of electronic tongue with different analytical techniques
    Rudnitskaya, Alisa
    Kirsanov, Dmitri
    Legin, Andrey
    Beullens, Katrien
    Lammertyn, Jeroen
    Nicolai, Bart M.
    Irudayaraj, Joseph
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2006, 116 (1-2) : 23 - 28
  • [59] Saidi T., 2017, IEEE INT S OLF EL NO, P1
  • [60] Exhaled breath gas sensing using pristine and functionalized WO3 nanowire sensors enhanced by UV-light irradiation
    Saidi, Tarik
    Palmowski, Dariusz
    Babicz-Kiewlicz, Sylwia
    Welearegay, Tesfalem Geremariam
    El Bari, Nezha
    Ionescu, Radu
    Smulko, Janusz
    Bouchikhi, Benachir
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2018, 273 : 1719 - 1729