Assessing validation of dual fluoroscopic image matching method for measurement of in vivo spine kinematics

被引:9
作者
Bai Jian-qiang [1 ,2 ]
Hu Yong-cheng [2 ]
Du Li-qing [3 ,4 ]
He Jing-liang [2 ]
Liu Kai [2 ]
Liu Zhong-jun [1 ]
Xia Qun [2 ]
机构
[1] Peking Univ, Hosp 3, Dept Orthopaed, Beijing 100191, Peoples R China
[2] Tianjin Hosp, Dept Spinal Surg, Tianjin 300211, Peoples R China
[3] Peking Union Med Coll, Tianjin Key Lab Mol Nucl Med, Tianjin 300192, Peoples R China
[4] Chinese Acad Med Sci, Inst Radiat Med, Tianjin 300192, Peoples R China
关键词
lumbar spine; validation; dual fluoroscopes; matching method; LUMBAR SPINE; CERVICAL-SPINE; SEGMENTAL MOTION; AXIAL ROTATION; REGISTRATION; ACCURACY; ERRORS; SYSTEM;
D O I
10.3760/cma.j.issn.0366-6999.2011.11.016
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Accurate knowledge of the spinal structural functions is critical to understand the biomechanical factors that affect spinal pathology. Many studies have investigated the human vertebral motion both in vitro and in vivo. However, determination of in vivo motion of the vertebrae under physiologic loading conditions remains a challenge in biomedical engineering because of the limitations of current technology and the complicated anatomy of the spine. Methods For in vitro validation, a human lumbar specimen was imbedded with steel beads and moved to a known distance by an universal testing machine (UTM). The dual fluoroscopic system was used to capture the spine motion and reproduce the moving distance. For in vivo validation, a living subject moved the spine in various positions while bearing weight. The fluoroscopes were used to reproduce the in vivo spine positions 5 times. The standard deviations in translation and orientation of the five measurements were used to evaluate the repeatability of technique. The accuracy of vertebral outline matching with metallic marks matching technology was compared. Results The translation positions of the human lumbar specimen could be determined with a mean accuracy less than 0.35 mm and a mean repeatability 0.36 mm for the image matching technique. The repeatability of the method in reproducing in vivo human spine six degrees of freedom (6DOF) kinematics was less than 0.43 mm in translation and less than 0.65 degrees in rotation. The accuracy of metallic marks and vertebral outline matching did not show significant difference. Conclusions Combining a dual fluoroscopic and computerized tomography imaging technique was accurate and reproduceable for noninvasive measurement of spine vertebral motion. The vertebral outline matching technique could be a useful technique for matching of vertebral positions and orientations which can evaluate and improve the efficacy of the various surgical treatments. Chin Med J 2011;124(11):1689-1694
引用
收藏
页码:1689 / 1694
页数:6
相关论文
共 25 条
[21]   Application of image registration to measurement of intervertebral rotation in the lumbar spine [J].
Rogers, BP ;
Haughton, VM ;
Arfanakis, K ;
Meyerand, ME .
MAGNETIC RESONANCE IN MEDICINE, 2002, 48 (06) :1072-1075
[22]   A new technique for measuring lumbar segmental motion in vivo - Method, accuracy, and preliminary results [J].
Steffen, T ;
Rubin, RK ;
Baramki, HG ;
Antoniou, J ;
Marchesi, D ;
Aebi, M .
SPINE, 1997, 22 (02) :156-166
[23]   Measurement of vertebral kinematics using noninvasive image matching method - Validation and application [J].
Wang, Shaobai ;
Passias, Peter ;
Li, Gang ;
Li, Guoan ;
Wood, Kirkham .
SPINE, 2008, 33 (11) :E355-E361
[24]   Continuous dynamic spinal motion analysis [J].
Wong, KWN ;
Luk, KDK ;
Leong, JCY ;
Wong, SF ;
Wong, KKY .
SPINE, 2006, 31 (04) :414-419
[25]   In vivo range of motion of the lumbar spinous processes [J].
Xia, Qun ;
Wang, Shaobai ;
Passias, Peter G. ;
Kozanek, Michal ;
Li, Gang ;
Grottkau, Brian E. ;
Wood, Kirkham B. ;
Li, Guoan .
EUROPEAN SPINE JOURNAL, 2009, 18 (09) :1355-1362