Radiologists' performance in the detection of benign and malignant masses with 3D automated breast ultrasound (ABUS)

被引:58
作者
Chang, Jung Min [1 ,2 ,3 ]
Moon, Woo Kyung [1 ,2 ,3 ]
Cho, Nariya [1 ,2 ,3 ]
Park, Jeong Seon [4 ]
Kim, Seung Ja [5 ]
机构
[1] Seoul Natl Univ Hosp, Dept Radiol, Seoul 100744, South Korea
[2] Seoul Natl Univ Hosp, Clin Res Inst, Seoul 100744, South Korea
[3] Seoul Natl Univ, Inst Radiat Med, Med Res Ctr, Seoul 151, South Korea
[4] Hanyang Univ, Coll Med, Hanyang Univ Hosp, Dept Radiol, Seoul, South Korea
[5] Seoul Natl Univ, Boramea Hosp, Dept Radiol, Seoul 151, South Korea
关键词
Automated breast US; Hand-held ultrasound; Screen US; Detection performance; PHYSICAL-EXAMINATION; MAMMOGRAPHY; CANCER; US; SONOGRAPHY; CARCINOMA; LESIONS; WORK;
D O I
10.1016/j.ejrad.2011.01.074
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: To retrospectively evaluate the detection performance of benign and malignant breast masses using 3D volume data obtained by ABUS and to determine lesion variables which affect detectability. Methods: Between November and December of 2007, bilateral whole breast US images were obtained using ABUS in 67 consecutive women who were scheduled to undergo US-guided needle biopsy due to suspicious breast masses. Twenty-four invasive ductal cancers in 23 breasts, 46 benign breast lesions in 44 breasts and 38 normal breasts were included. Three breast radiologists (experience range, 8-16 years) who did not perform the examinations and were blinded to the histology independently reviewed the ABUS data of the 105 breasts to detect suspicious solid masses with pathology as the standard of reference. Sensitivity and specificity in detecting benign and malignant masses were calculated, and lesion characteristics affecting detectability were analyzed. Results: Sensitivities for benign and malignant mass detections were 65.2% (30/46), 95.8% (23/24) for reader 1 (p = 0.007), 66.7% (31/46), 87.5% (21/24) for reader 2 (p = 0.087), and 56.3% (24/46), 91.7% (22/24), for reader 3 (p = 0.001), respectively. Logistic analysis showed that mass size (odds ratio, 95% CI; 1.12, 1.02-1.24), surrounding tissue changes (odds ratio, 95% CI; 0.11, 0.02-0.47), and shape of the mass (odds ratio, 95% CI; 3.12, 1.02-9.55) were the variables associated with detectability at ABUS. Conclusion: In reader studies using ABUS data, significantly higher sensitivity was noted for malignant breast masses than for benign masses. (C) 2011 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:99 / 103
页数:5
相关论文
共 24 条
[1]   AUTOMATED AND HAND-HELD BREAST US - EFFECT ON PATIENT-MANAGEMENT [J].
BASSETT, LW ;
KIMMESMITH, C ;
SUTHERLAND, LK ;
GOLD, RH ;
SARTI, D ;
KING, W .
RADIOLOGY, 1987, 165 (01) :103-108
[2]   Combined screening with ultrasound and mammography vs mammography alone in women at elevated risk of breast cancer [J].
Berg, Wendie A. ;
Blume, Jeffrey D. ;
Cormack, Jean B. ;
Mendelson, Ellen B. ;
Lehrer, Daniel ;
Bohm-Velez, Marcela ;
Pisano, Etta D. ;
Jong, Roberta A. ;
Evans, W. Phil ;
Morton, Marilyn J. ;
Mahoney, Mary C. ;
Larsen, Linda Hovanessian ;
Barr, Richard G. ;
Farria, Dione M. ;
Marques, Helga S. ;
Boparai, Karan .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2008, 299 (18) :2151-2163
[3]   Tailored Supplemental Screening for Breast Cancer: What Now and What Next? [J].
Berg, Wendie A. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 192 (02) :390-399
[4]   Incidental findings on sonography of the breast:: Clinical significance and diagnostic workup [J].
Buchberger, W ;
DeKoekkoek-Doll, P ;
Springer, P ;
Obrist, P ;
Dünser, M .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 173 (04) :921-927
[5]  
CHIANG HR, 2006, ULTRASOUND MED BIOL, V32, P107
[6]  
CHOU YH, 2006, RADIOLOGICAL SOC N A
[7]   Automated Full-field Breast Ultrasonography: The Past and The Present [J].
Chou, Yi-Hong ;
Tiu, Chui-Mei ;
Chen, Jiayu ;
Chang, Ruey-Feng .
JOURNAL OF MEDICAL ULTRASOUND, 2007, 15 (01) :31-44
[8]  
DESTOUNIS S, 2005, RADIOLOGICAL SOC N A
[9]   The impact of organized mammography service screening on breast carcinoma mortality in seven Swedish counties -: A collaborative evaluation [J].
Duffy, SW ;
Tabár, L ;
Chen, HH ;
Holmqvist, M ;
Yen, MF ;
Abdsalah, S ;
Epstein, B ;
Frodis, E ;
Ljungberg, E ;
Hedborg-Melander, C ;
Sundbom, A ;
Tholin, M ;
Wiege, M ;
Åkerlund, A ;
Wu, HM ;
Tung, TS ;
Chiu, YH ;
Chiu, CP ;
Huang, CC ;
Smith, RA ;
Rosén, M ;
Stenbeck, M ;
Holmberg, L .
CANCER, 2002, 95 (03) :458-469
[10]   DETECTION OF BREAST-CARCINOMA - COMPARISON OF AUTOMATED WATER-PATH WHOLE-BREAST SONOGRAPHY, MAMMOGRAPHY, AND PHYSICAL-EXAMINATION [J].
EGAN, RL ;
EGAN, KL .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1984, 143 (03) :493-497