Effect of the solvent flow rate on the ionization efficiency in atmospheric pressure photoionization-mass spectrometry

被引:61
作者
Kauppila, TJ
Bruins, AP
Kostiainen, R
机构
[1] Univ Groningen, Ctr Pharm, NL-9713 AV Groningen, Netherlands
[2] Univ Helsinki, Fac Pharm, Div Pharmaceut Chem, Viikki Drug Discovery Technol Ctr, FIN-00014 Helsinki, Finland
关键词
D O I
10.1016/j.jasms.2005.03.051
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In the novel atmospheric pressure photoionization-mass spectrometry the ionization efficiency has been observed to decrease when the solvent flow rate is increased. The effect of the flow rate on the ionization efficiency was studied by comparing the behavior of two analytes, one of which is ionized through charge exchange, the other through proton transfer. Additional information about the ion loss mechanisms was obtained by comparing results obtained with two different APPI ion sources: a Sciex prototype and the Agilent/Syagen APPI source. In addition to the measurements done by using the mass analyzer, the total ion current in the ion source was obtained by measuring the currents of the ions arriving at curtain/end plate and orifice/capillary of the two mass spectrometers. The total ion current measurements showed a significant decrease at high solvent flow rates. Loss of dopant radical cations was thought to be the reason for the signal decrease of the analytes formed through charge exchange. Analytes formed through proton transfer were not as seriously affected by the high solvent flow rates, but some saturation of their signal was nevertheless observed. Loss of photons through absorption by solvent vapor is another mechanism that can be held responsible for a reduction of the total number of ions produced by the APPI source.
引用
收藏
页码:1399 / 1407
页数:9
相关论文
共 28 条
[1]   On the formation of negative ions in atmospheric pressure photoionization conditions [J].
Basso, E ;
Marotta, E ;
Seraglia, R ;
Tubaro, M ;
Traldi, P .
JOURNAL OF MASS SPECTROMETRY, 2003, 38 (10) :1113-1115
[2]  
COVEY TR, 1986, ANAL CHEM, V58, P1451
[3]   Characterization of hydrophobic peptides by atmospheric pressure photoionization-mass spectrometry and tandem mass spectrometry [J].
Delobel, A ;
Halgand, F ;
Laffranchise-Gosse, B ;
Snijders, H ;
Laprévote, O .
ANALYTICAL CHEMISTRY, 2003, 75 (21) :5961-5968
[4]   High resolution photo-absorption studies of acrylonitrile, C2H3CN, and acetonitrile, CH3CN [J].
Eden, S ;
Limao-Vieira, P ;
Kendall, P ;
Mason, NJ ;
Hoffmann, SV ;
Spyrou, SM .
EUROPEAN PHYSICAL JOURNAL D, 2003, 26 (02) :201-210
[5]   Development of LC/MS/MS methods for cocktail dosed Caco-2 samples using atmospheric pressure photoionization and electrospray ionization [J].
Hakala, KS ;
Laitinen, L ;
Kaukonen, AM ;
Hirvonen, J ;
Kostiainen, R ;
Kotiaho, T .
ANALYTICAL CHEMISTRY, 2003, 75 (21) :5969-5977
[6]   Atmospheric pressure photoionization. 1. General properties for LC/MS [J].
Hanold, KA ;
Fischer, SM ;
Cormia, PH ;
Miller, CE ;
Syage, JA .
ANALYTICAL CHEMISTRY, 2004, 76 (10) :2842-2851
[7]   Zirconia-based column high-performance liquid chromatography/atmospheric pressure photoionization tandem mass spectrometric analyses of drug molecules in rat plasma [J].
Hsieh, YS ;
Merkle, K ;
Wang, GF .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2003, 17 (15) :1775-1780
[8]   High-performance liquid chromatography-atmospheric pressure photoionization/tandem mass spectrometric analysis for small molecules in plasma [J].
Hsieh, YS ;
Merkle, K ;
Wang, GF ;
Brisson, JM ;
Korfmacher, WA .
ANALYTICAL CHEMISTRY, 2003, 75 (13) :3122-3127
[9]   Anisole, a new dopant for atmospheric pressure photoionization mass spectrometry of low proton affinity, low ionization energy compounds [J].
Kauppila, TJ ;
Kostiainen, R ;
Bruins, AP .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2004, 18 (07) :808-815
[10]   Negative ion-atmospheric pressure photoionization-mass spectrometry [J].
Kauppila, TJ ;
Kotiaho, T ;
Kostiainen, R ;
Bruins, AP .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2004, 15 (02) :203-211