Performance analysis of a solar-assisted ground-source heat pump system for greenhouse heating: an experimental study

被引:151
作者
Ozgener, O
Hepbasli, A [1 ]
机构
[1] Ege Univ, Fac Engn, Dept Mech Engn, TR-35100 Izmir, Turkey
[2] Ege Univ, Solar Energy Inst, TR-35100 Izmir, Turkey
关键词
performance analysis; solar-assisted ground-source heat pump; greenhouse heating; Izmir;
D O I
10.1016/j.buildenv.2004.08.030
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This study investigates the performance characteristics of a solar-assisted ground-source (geothermal) heat pump system (SAGSHPS) for greenhouse heating with a 50 in vertical 32 mm nominal diameter U-bend ground heat-exchanger. This system was designed and installed in the Solar Energy Institute, Ege University, Izmir (568 degree days cooling, base: 22 degrees C, 1226 degree days heating, base: 18 degrees C), Turkey.,Based upon the measurements made in the heating mode from the 20th of January till 31st of March 2004, the heat extraction rate from the soil is found to be, on average, 57.78 W/m of bore depth, while the required borehole length in metre per kW of capacity is obtained as 11.92. Design practices in Turkey normally call for U-bend depths between 11 and 13 m/kW of heating. The entering water temperature to the unit ranges from 8.2 to 16.2 degrees C, with an average value of WC. The greenhouse air has a maximum day temperature of 31.05 degrees C and night temperature of 14.54 degrees C with a relative humidity of 40.35%. The heating coefficient of performance of the heat PUMP (COPHP) is about 2.00 at the end of a cloudy day, while it is about 3.13 at the end of sunny day and fluctuates between these values in other times. The COP values for the whole system are also obtained to be 5-20% lower than COPHP. The clearness index during experimental period is computed as average 0.56. At the same period, Cucumus sativus cv. Pandora F, was raised, and product quality was improved with the climatic conditions in the designed SAGSHPS. However, experimental results show that monovalent central heating operation (independent of any other heating system) cannot meet the overall heat loss of the greenhouse if the ambient temperature is very low. The bivalent operation (combined with other heating system) can be suggested as the best solution in Mediterranean and Aegean regions of Turkey. (c) 2004 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1040 / 1050
页数:11
相关论文
共 38 条
[1]  
Albright L. D., 1991, Solar energy in agriculture., P213
[2]  
[Anonymous], 2003, GREENHOUSE HEATING R
[3]  
*ASHRAE, 1974, ASHRAE HDB APPL, pCH22
[5]  
BAYTARUN N, 1997, P INT WORKSH STRAT G, P100
[6]   Solar and ground source heat-pump system [J].
Bi, YH ;
Guo, TW ;
Zhang, L ;
Chen, LG .
APPLIED ENERGY, 2004, 78 (02) :231-245
[7]  
Bloomquist RG, 2000, P WORLD GEOTH C 2000, P3373
[8]  
Chaturvedi S. K, 1997, ENERGY CONVERSION MA, V39, P181
[9]   On the study of an energy-efficient greenhouse for heating, cooling and dehumidification applications [J].
Chou, SK ;
Chua, KJ ;
Ho, JC ;
Ooi, CL .
APPLIED ENERGY, 2004, 77 (04) :355-373
[10]   Performance analysis of a solar-assisted heat pump water heater [J].
Chyng, JP ;
Lee, CP ;
Huang, BJ .
SOLAR ENERGY, 2003, 74 (01) :33-44