Application of a six sigma model to evaluate the analytical performance of urinary biochemical analytes and design a risk-based statistical quality control strategy for these assays: A multicenter study

被引:7
作者
Liu, Qian [1 ]
Bian, Guangrong [1 ]
Chen, Xinkuan [2 ]
Han, Jingjing [3 ]
Chen, Ying [4 ]
Wang, Menglin [5 ]
Yang, Fumeng [1 ]
机构
[1] Second Peoples Hosp Lianyungang, Dept Lab Med, 41 East Haitian Rd, Lianyungang 222006, Peoples R China
[2] Xuzhou Med Univ, Dept Lab Med, Affiliated Hosp Lianyungang, Lianyungang, Peoples R China
[3] Ruijin Hosp, Dept Lab Med, Wuxi Branch, Wuxi, Jiangsu, Peoples R China
[4] Nantong Hosp Tradit Chinese Med, Dept Lab Med, Nantong, Peoples R China
[5] Sugian First Hosp, Dept Lab Med, Suclian, Peoples R China
关键词
analytical performance; quality goal index; risk-based statistical quality control strategy; six sigma; urinary biochemical analytes; CREATININE RATIO; POTASSIUM; EXCRETION; SODIUM;
D O I
10.1002/jcla.24059
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background The six sigma model has been widely used in clinical laboratory quality management. In this study, we first applied the six sigma model to (a) evaluate the analytical performance of urinary biochemical analytes across five laboratories, (b) design risk-based statistical quality control (SQC) strategies, and (c) formulate improvement measures for each of the analytes when needed. Methods Internal quality control (IQC) and external quality assessment (EQA) data for urinary biochemical analytes were collected from five laboratories, and the sigma value of each analyte was calculated based on coefficients of variation, bias, and total allowable error (TEa). Normalized sigma method decision charts for these urinary biochemical analytes were then generated. Risk-based SQC strategies and improvement measures were formulated for each laboratory according to the flowchart of Westgard sigma rules, including run sizes and the quality goal index (QGI). Results Sigma values of urinary biochemical analytes were significantly different at different quality control levels. Although identical detection platforms with matching reagents were used, differences in these analytes were also observed between laboratories. Risk-based SQC strategies for urinary biochemical analytes were formulated based on the flowchart of Westgard sigma rules, including run size and analytical performance. Appropriate improvement measures were implemented for urinary biochemical analytes with analytical performance lower than six sigma according to the QGI calculation. Conclusions In multilocation laboratory systems, a six sigma model is an excellent quality management tool and can quantitatively evaluate analytical performance and guide risk-based SQC strategy development and improvement measure implementation.
引用
收藏
页数:9
相关论文
共 36 条
  • [1] EVALUATION OF ANALYTICAL PERFORMANCE OF VARIANT II TURBO HBA1C ANALYZER ACCORDING TO SIGMA METRICS
    Bozkaya, Giray
    Uzuncan, Nuriye
    Bilgili, Sibel
    Demirezen, Ozlem
    [J]. JOURNAL OF MEDICAL BIOCHEMISTRY, 2019, 38 (01) : 33 - 37
  • [2] Criteria for assigning laboratory measurands to models for analytical performance specifications defined in the 1st EFLM Strategic Conference
    Ceriotti, Ferruccio
    Fernandez-Calle, Pilar
    Klee, George G.
    Nordin, Gunnar
    Sandberg, Sverre
    Streichert, Thomas
    Vives-Corrons, Joan-Lluis
    Panteghini, Mauro
    [J]. CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2017, 55 (02) : 189 - 194
  • [3] Determination of Six Sigma Metric in Control of Enzymes Determination in Human Serum
    Dido, Vedran
    Coric, Jozo
    Mujic, Jasminka
    Panjeta, Mirsad
    Bodulovic, Aleksandar
    Marjanovic, Marijan
    [J]. CLINICAL LABORATORY, 2019, 65 (07) : 1309 - 1312
  • [4] Multi-site performance evaluation and Sigma metrics of 20 assays on the Atellica chemistry and immunoassay analyzers
    Fasano, Tommaso
    Luis Bedini, Jose
    Fle, Pierre-Antoine
    Jlaiel, Malik
    Hubbert, Karl
    Datta, Harish
    Chicha-Cattoir, Valerie
    Mansour, Hayfa
    Mira, Aurea
    Gonzalez de la Presa, Bernardino
    Rico, Nayra
    Sanz de Pedro, Maria
    Diaz-Garzon, Jorge
    Buno Soto, Antonio
    Vecchia, Luigi
    Peoc'h, Katell
    [J]. CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2020, 58 (01) : 59 - 68
  • [5] Albumin Urinary Excretion Is Associated with Increased Levels of Urinary Chemokines, Cytokines, and Growth Factors Levels in Humans
    Fellstrom, Bengt
    Helmersson-Karlqvist, Johanna
    Lind, Lars
    Soveri, Inga
    Thulin, Mans
    Arnlov, Johan
    Kultima, Kim
    Larsson, Anders
    [J]. BIOMOLECULES, 2021, 11 (03) : 1 - 8
  • [6] The Association between Urinary Glucose and Renal Uric Acid Excretion in Non-diabetic Patients with Stage 1-2 Chronic Kidney Disease
    Feng, Xinhui
    Zheng, Yuqi
    Guan, Haochen
    Zhou, Xun
    Xu, Ying
    Zhang, Xiaoli
    Fu, Chensheng
    Xiao, Jing
    Ye, Zhibin
    [J]. ENDOCRINE RESEARCH, 2021, 46 (01) : 28 - 36
  • [7] Analysis of performance of clinical biochemistry laboratory using Sigma metrics and Quality Goal Index
    Goel, Parul
    Malik, Gagandeep
    Prasad, Suvarna
    Rani, Isha
    Manhas, Sunita
    Goel, Kapil
    [J]. PRACTICAL LABORATORY MEDICINE, 2021, 23
  • [8] Sigma metrics for assessing the analytical quality of clinical chemistry assays: a comparison of two approaches
    Guo, Xiuzhi
    Zhang, Tianjiao
    Gao, Xuehui
    Li, Pengchang
    You, Tingting
    Wu, Qiong
    Wu, Jie
    Zhao, Fang
    Xia, Liangyu
    Xu, Ermu
    Qiu, Ling
    Cheng, Xinqi
    [J]. BIOCHEMIA MEDICA, 2018, 28 (02)
  • [9] Performance evaluation of HbA1c measurement systems with sigma metric for 1066 laboratories in China
    Huang, Yuzhu
    Zhang, Tianjiao
    Zhao, Haijian
    Wang, Wei
    Zhang, Chuanbao
    He, Falin
    Zhong, Kun
    Yuan, Shuai
    Du, Yuxuan
    Wang, Zhiguo
    [J]. CLINICA CHIMICA ACTA, 2018, 487 : 281 - 286
  • [10] High urinary glucose is associated with improved renal prognosis in patients with diabetes mellitus
    Itano, Yuya
    Sobajima, Hiroshi
    Ohashi, Norimi
    Shibata, Taiga
    Fujiya, Atsushi
    Nagata, Takanobu
    Ando, Masahiko
    Imaizumi, Takahiro
    Kubo, Yoko
    Ozeki, Takaya
    Katsuno, Takayuki
    Kato, Sawako
    Yasuda, Yoshinari
    Maruyama, Shoichi
    [J]. JOURNAL OF DIABETES INVESTIGATION, 2021, 12 (06) : 998 - 1006