Complications related to use of mesh implants in surgical treatment of stress urinary incontinence and pelvic organ prolapse: infection or inflammation?

被引:71
作者
Mangir, Naside [1 ,2 ]
Roman, Sabiniano [1 ]
Chapple, Christopher R. [2 ]
MacNeil, Sheila [1 ]
机构
[1] Univ Sheffield, Kroto Res Inst, Dept Mat Sci & Engn, Sheffield, S Yorkshire, England
[2] Royal Hallamshire Hosp, Dept Urol, Sheffield, S Yorkshire, England
关键词
Stress urinary incontinence; Pelvic organ prolapse; Surgical mesh; Polypropylene; Infection; Inflammation; WEIGHT POLYPROPYLENE MESHES; FREE VAGINAL TAPE; CAPSULAR CONTRACTURE; BACTERIAL BIOFILMS; SURGERY; REPAIR; SACROCOLPOPEXY; ATTACHMENT; MANAGEMENT; SITE;
D O I
10.1007/s00345-019-02679-w
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
The surgical mesh material used in the surgical treatment of stress urinary incontinence (SUI) and pelvic organ prolapse (POP) in women is associated with significant complications in some women. This has recently become a public health issue with involvement of national parliaments and regulatory bodies. The occurrence of mesh complications is thought to be a result of multifactorial processes involving problems related to the material design, the surgical techniques used and disease, and patient-related factors. However, the infectious complications and mesh-tissue interactions are least studied. The aim of this article is to review any previous clinical and basic scientific evidence about the contribution of infectious and inflammatory processes to the occurrence of mesh-related complications in SUI and POP. A literature search for the relevant publications without any time limits was performed on the Medline database. There is evidence to show that vaginal meshes are associated with an unfavourable host response at the site of implantation. The underlying mechanisms leading to this type of host response is not completely clear. Mesh contamination with vaginal flora during surgical implantation can be a factor modifying the host response if there is a subclinical infection that can trigger a sustained inflammation. More basic science research is required to identify the biological mechanisms causing a sustained inflammation at the mesh-tissue interface that can then lead to contraction, mesh erosion, and pain.
引用
收藏
页码:73 / 80
页数:8
相关论文
共 57 条
[1]   Complications of tension-free vaginal tape surgery: a multi-institutional review [J].
Abouassaly, R ;
Steinberg, JR ;
Lemieux, M ;
Marois, C ;
Gilchrist, LI ;
Bourque, JL ;
Tu, LM ;
Corcos, J .
BJU INTERNATIONAL, 2004, 94 (01) :110-113
[2]   Electrospun Polystyrene Fiber Diameter Influencing Bacterial Attachment, Proliferation, and Growth [J].
Abrigo, Martina ;
Kingshott, Peter ;
McArthur, Sally L. .
ACS APPLIED MATERIALS & INTERFACES, 2015, 7 (14) :7644-7652
[3]   Electrospun Nanofibers as Dressings for Chronic Wound Care: Advances, Challenges, and Future Prospects [J].
Abrigo, Martina ;
McArthur, Sally L. ;
Kingshott, Peter .
MACROMOLECULAR BIOSCIENCE, 2014, 14 (06) :772-792
[4]   Capsular Contracture: What is It? What Causes It? How Can It Be Prevented and Managed? [J].
Adams, William P., Jr. .
CLINICS IN PLASTIC SURGERY, 2009, 36 (01) :119-126
[5]   The Relationship of Bacterial Biofilms and Capsular Contracture in Breast Implants [J].
Ajdic, Dragana ;
Zoghbi, Yasmina ;
Gerth, David ;
Panthaki, Zubin J. ;
Thaller, Seth .
AESTHETIC SURGERY JOURNAL, 2016, 36 (03) :297-309
[6]  
[Anonymous], 2014, F1000PRIME REPORTS
[7]   Implant infections: adhesion, biofilm formation and immune evasion [J].
Arciola, Carla Renata ;
Campoccia, Davide ;
Montanaro, Lucio .
NATURE REVIEWS MICROBIOLOGY, 2018, 16 (07) :397-409
[8]   Tunable Antimicrobial Polypropylene Surfaces: Simultaneous Attachment of Penicillin (Gram plus ) and Gentamicin (Gram -) [J].
Aumsuwan, Nattharika ;
McConnell, Matthew S. ;
Urban, Marek W. .
BIOMACROMOLECULES, 2009, 10 (03) :623-629
[9]   In vitro and in vivo assessment of silver-coated polypropylene mesh to prevent infection in a rat model [J].
Badiou, Wassim ;
Lavigne, Jean-Philippe ;
Bousquet, Philippe-Jean ;
O'Callaghan, David ;
Mares, Pierre ;
de Tayrac, Renaud .
INTERNATIONAL UROGYNECOLOGY JOURNAL, 2011, 22 (03) :265-272
[10]   Tissue integration and biomechanical behaviour of contaminated experimental polypropylene and expanded polytetrafluoroethylene implants [J].
Bellón, JM ;
García-Carranza, A ;
García-Honduvilla, N ;
Carrera-San Martín, A ;
Buján, J .
BRITISH JOURNAL OF SURGERY, 2004, 91 (04) :489-494