Time-resolved absolute radius estimation of vibrating contrast microbubbles using an acoustical camera

被引:7
作者
Spiekhout, Sander [1 ]
Voorneveld, Jason [1 ]
van Elburg, Benjamin [2 ,3 ]
Renaud, Guillaume [4 ]
Segers, Tim [5 ]
Lajoinie, Guillaume P. R. [2 ,3 ]
Versluis, Michel [2 ,3 ]
Verweij, Martin D. [1 ,4 ]
de Jong, Nico [1 ,4 ]
Bosch, Johannes G. [1 ]
机构
[1] Univ Med Ctr Rotterdam, Biomed Engn, Erasmus MC, Rotterdam, Netherlands
[2] Univ Twente, MESA Inst Nanotechnol, Dept Sci & Technol, Phys Fluids Grp, Enschede, Netherlands
[3] Univ Twente, Tech Med TechMed Ctr, Enschede, Netherlands
[4] Delft Univ Technol, Dept Imaging Phys, Lab Med Imaging, Delft, Netherlands
[5] Univ Twente, Max Planck Ctr Complex Fluid Dynam, Biomed & Environm Sensor Syst BIOS Lab On a chip G, Enschede, Netherlands
基金
荷兰研究理事会;
关键词
COMPRESSION-ONLY BEHAVIOR; DOPPLER-EFFECT ANALYSIS; COATED MICROBUBBLES; SOUND-SCATTERING; ULTRASOUND; SPECTROSCOPY; OSCILLATIONS; BUBBLES; AGENTS;
D O I
10.1121/10.0011619
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Ultrasound (US) contrast agents consist of microbubbles ranging from 1 to 10 mu m in size. The acoustical response of individual microbubbles can be studied with high-frame-rate optics or an "acoustical camera " (AC). The AC measures the relative microbubble oscillation while the optical camera measures the absolute oscillation. In this article, the capabilities of the AC are extended to measure the absolute oscillations. In the AC setup, microbubbles are insonified with a high- (25 MHz) and low-frequency US wave (1-2.5 MHz). Other than the amplitude modulation (AM) from the relative size change of the microbubble (employed in Renaud, Bosch, van der Steen, and de Jong (2012a). "An 'acoustical camera' for in vitro characterization of contrast agent microbubble vibrations, " Appl. Phys. Lett. 100(10), 101911, the high-frequency response from individual vibrating microbubbles contains a phase modulation (PM) from the microbubble wall displacement, which is the extension described here. The ratio of PM and AM is used to determine the absolute radius, R-0. To test this sizing, the size distributions of two monodisperse microbubble populations ( R 0 = 2.1 and 3.5 mu m) acquired with the AC were matched to the distribution acquired with a Coulter counter. As a result of measuring the absolute size of the microbubbles, this "extended AC " can capture the full radial dynamics of single freely floating microbubbles with a throughput of hundreds of microbubbles per hour.
引用
收藏
页码:3993 / 4003
页数:11
相关论文
共 50 条
[21]   Time-Resolved Passive Cavitation Mapping Using the Transient Angular Spectrum Approach [J].
Li, Mucong ;
Gu, Juanjuan ;
Vu, Tri ;
Sankin, Georgy ;
Zhong, Pei ;
Yao, Junjie ;
Jing, Yun .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2021, 68 (07) :2361-2369
[22]   Probing ultrafast dynamics of chiral molecules using time-resolved photoelectron circular dichroism [J].
Beaulieu, Samuel ;
Comby, Antoine ;
Fabre, Baptiste ;
Descamps, Dominique ;
Ferre, Amelie ;
Garcia, Gustavo ;
Geneaux, Romain ;
Legare, Francois ;
Nahon, Laurent ;
Petit, Stephane ;
Ruchon, Thierry ;
Pons, Bernard ;
Blanchet, Valerie ;
Mairesse, Yann .
FARADAY DISCUSSIONS, 2016, 194 :325-348
[23]   From Protohypericin to Hypericin: Photoconversion Analysis Using a Time-Resolved Thermal Lens Technique [J].
Camargo, Vinicius G. ;
Zanuto, Vitor S. ;
Astrath, Nelson G. C. ;
Caetano, Wilker ;
Hioka, Noboru ;
Pereira, Paulo C. S. ;
Goncalves, Renato S. ;
Lukasievicz, Gustavo V. B. ;
Herculano, Leandro S. ;
Malacarne, Luis C. .
APPLIED SPECTROSCOPY, 2019, 73 (08) :936-944
[24]   Effective Electron Temperature Measurement Using Time-Resolved Anti-Stokes Photoluminescence [J].
Jollans, Thomas ;
Caldarola, Martin ;
Sivan, Yonatan ;
Orrit, Michel .
JOURNAL OF PHYSICAL CHEMISTRY A, 2020, 124 (34) :6968-6976
[25]   Nondestructive Food Quality Monitoring Using Phase Information in Time-Resolved Reflectance Spectroscopy [J].
Sarkar, Mukul ;
Gupta, Nitin ;
Assaad, Maher .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2020, 69 (10) :7787-7795
[26]   Towards Operando Electron Transfer Dynamics Measured Using Time-Resolved Terahertz Spectroelectrochemistry [J].
Spies, Jacob A. ;
Tayvah, Uriel T. ;
Neu, Jens ;
Brudvig, Gary W. ;
Schmuttenmaer, Charles A. .
2021 46TH INTERNATIONAL CONFERENCE ON INFRARED, MILLIMETER AND TERAHERTZ WAVES (IRMMW-THZ), 2021,
[27]   Raman linewidth measurements using time-resolved hybrid picosecond/nanosecond rotational CARS [J].
Nordstrom, Emil ;
Hosseinnia, Ali ;
Brackmann, Christian ;
Bood, Joakim ;
Bengtsson, Per-Erik .
OPTICS LETTERS, 2015, 40 (24) :5718-5721
[28]   Time-resolved photoacoustic response of thin solids measured using minimal volume cell [J].
Galovic, S. P. ;
Stanimirovic, Z. ;
Stanimirovic, I. ;
Djordjevic, K. Lj. ;
Milicevic, D. ;
Suljovrujic, E. .
INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2024, 155
[29]   Characterization and detection of adulterated whey protein supplements using stationary and time-resolved fluorescence spectroscopy [J].
Pereira, Cristina Guimaraes ;
Andrade, Jonathan ;
Ranquine, Thamiris ;
de Moura, Israel Novaes ;
da Rocha, Roney Alves ;
Moreira Furtado, Marco Antonio ;
Valenzuela Bell, Maria Jose ;
Anjos, Virgilio .
LWT-FOOD SCIENCE AND TECHNOLOGY, 2018, 97 :180-186
[30]   Time-resolved ion energy measurements using a retarding potential analyzer for electric propulsion applications [J].
Thomas, Austen ;
Lemmer, Kristina .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2024, 95 (02)