High-energy X-ray grating-based phase-contrast radiography of human anatomy

被引:1
作者
Horn, Florian [1 ]
Hauke, Christian [1 ]
Lachner, Sebastian [1 ]
Ludwig, Veronika [1 ]
Pelzer, Georg [1 ]
Rieger, Jens [1 ]
Schuster, Max [1 ]
Seifert, Maria [1 ]
Wandner, Johannes [1 ]
Wolf, Andreas [1 ]
Michel, Thilo [1 ]
Anton, Gisela [1 ]
机构
[1] Univ Erlangen Nurnberg, ECAP Novel Detectors Med Phys, Erwin Rommel Str 1, D-91058 Erlangen, Germany
来源
MEDICAL IMAGING 2016: PHYSICS OF MEDICAL IMAGING | 2016年 / 9783卷
关键词
X-ray imaging; differential phase-contrast; Talbot-Lau interferometry; high energy; radiography;
D O I
10.1117/12.2216893
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
X-ray grating-based phase-contrast Talbot-Lau interferometry is a promising imaging technology that has the potential to raise soft tissue contrast in comparison to conventional attenuation-based imaging. Additionally, it is sensitive to attenuation, refraction and scattering of the radiation and thus provides complementary and otherwise inaccessible information due to the dark-field image, which shows the sub-pixel size granularity of the measured object. Until recent progress the method has been mainly limited to photon energies below 40 keV. Scaling the method to photon energies that are sufficient to pass large and spacious objects represents a challenging task. This is caused by increasing demands regarding the fabrication process of the gratings and the broad spectra that come along with the use of polychromatic X-ray sources operated at high acceleration voltages. We designed a setup that is capable to reach high visibilities in the range from 50 to 120 kV. Therefore, spacious and dense parts of the human body with high attenuation can be measured, such as a human knee. The authors will show investigations on the resulting attenuation, differential phase-contrast and dark-field images. The images experimentally show that X-ray grating-based phase-contrast radiography is feasible with highly absorbing parts of the human body containing massive bones.
引用
收藏
页数:6
相关论文
共 8 条
[1]   Phase-contrast imaging and tomography at 60 keV using a conventional x-ray tube source [J].
Donath, Tilman ;
Pfeiffer, Franz ;
Bunk, Oliver ;
Groot, Waldemar ;
Bednarzik, Martin ;
Gruenzweig, Christian ;
Hempel, Eckhard ;
Popescu, Stefan ;
Hoheisel, Martin ;
David, Christian .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2009, 80 (05)
[2]  
Hauke C., 2016, P SPIE
[3]   Recent advances in X-ray phase imaging [J].
Momose, A .
JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS, 2005, 44 (9A) :6355-6367
[4]   Hard-X-ray dark-field imaging using a grating interferometer [J].
Pfeiffer, F. ;
Bech, M. ;
Bunk, O. ;
Kraft, P. ;
Eikenberry, E. F. ;
Broennimann, Ch. ;
Gruenzweig, C. ;
David, C. .
NATURE MATERIALS, 2008, 7 (02) :134-137
[5]   Phase retrieval and differential phase-contrast imaging with low-brilliance X-ray sources [J].
Pfeiffer, F ;
Weitkamp, T ;
Bunk, O ;
David, C .
NATURE PHYSICS, 2006, 2 (04) :258-261
[6]   Quantitative imaging using high-energy X-ray phase-contrast CT with a 70 kVp polychromatic X-ray spectrum [J].
Sarapata, Adrian ;
Willner, Marian ;
Walter, Marco ;
Duttenhofer, Thomas ;
Kaiser, Konradin ;
Meyer, Pascal ;
Braun, Christian ;
Fingerle, Alexander ;
Noeel, Peter B. ;
Pfeiffer, Franz ;
Herzen, Julia .
OPTICS EXPRESS, 2015, 23 (01) :523-535
[7]   X-ray phase imaging with a grating interferometer [J].
Weitkamp, T ;
Diaz, A ;
David, C ;
Pfeiffer, F ;
Stampanoni, M ;
Cloetens, P ;
Ziegler, E .
OPTICS EXPRESS, 2005, 13 (16) :6296-6304
[8]   Quantitative X-ray phase-contrast computed tomography at 82 keV [J].
Willner, Marian ;
Bech, Martin ;
Herzen, Julia ;
Zanette, Irene ;
Hahn, Dieter ;
Kenntner, Johannes ;
Mohr, Juergen ;
Rack, Alexander ;
Weitkamp, Timm ;
Pfeiffer, Franz .
OPTICS EXPRESS, 2013, 21 (04) :4155-4166