Experimental Investigation of Performance of Conventional Vapor Compression Refrigeration Cycle Using Geothermal Cooling in Extreme Hot Weather Conditions

被引:0
作者
Ismael, Mays Alaa [1 ]
Yahya, Samir Gh [1 ]
Azzawi, Itimad D. J. [1 ]
机构
[1] Univ Diyala, Coll Engn, Dept Mech Engn, Baqubah 32001, Iraq
关键词
conventional refrigeration; harsh climatic conditions; geothermal cooling; AIR HEAT-EXCHANGER; EARTH TUBE; SYSTEM; BUILDINGS;
D O I
10.18280/ijht.400212
中图分类号
O414.1 [热力学];
学科分类号
摘要
The well-known traditional vapor compression refrigeration cycle is considered to be the most effective technique used in the field of refrigeration and air-conditioning systems. It's used almost in every facility including industrials, homes and food storages. There are some environmental hazards concerning the use of vapor-compression cycles such as global warming and ozone layer depletion mainly due to refrigerant's leakages. However, it's still considered as a leading technology for its capability of producing high cooling and heating powers with great coefficient of performance. The present work represents an experimental investigation of the effect of the condenser's temperature on the thermal performance of a conventional vapor compression refrigeration cycle. The geothermal cooling technique was introduced and utilized for cooling the temperature of the condenser that operates in harsh climate conditions. The experiment was performed using two additional heat exchangers for enabling heat exchange with geothermal temperature. The first heat exchanger (primary HX1) was connected directly to the condenser while the other one (secondary HX2) was installed inside the geothermal hole intended for heat exchange with the geothermal temperature. These exchangers (HX1 and HX2) were thermally connected via two PVC tubes with straight water circulating inside them (using a DC water pump). The experimental results proved the success of the current utilized method in improving the thermal performance of the system. Cooling the condenser via geothermal cooling has led to a considerable reduction in the temperature of the refrigerant and improved the overall performance of the cycle. The experimental apparatus showed an increase in both cooling capacity and COP by 25% and 21.5%, respectively. In addition, a considerable enhancement in the temperature of the evaporator was accomplished to reach a minimum temperature of 14.5 degrees C.
引用
收藏
页码:449 / 456
页数:8
相关论文
共 32 条
[1]   Evaluation of an Earth-to-Air Heat Exchanger for the North-East of Iran with Semi-Arid Climate [J].
Abbaspour-Fard, Mohammad Hossein ;
Gholami, Adel ;
Khojastehpour, Mehdi .
INTERNATIONAL JOURNAL OF GREEN ENERGY, 2011, 8 (04) :499-510
[2]   A review on exergy analysis of vapor compression refrigeration system [J].
Ahamed, J. U. ;
Saidur, R. ;
Masjuki, H. H. .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2011, 15 (03) :1593-1600
[3]   The cooling potential of earth-air heat exchangers for domestic buildings in a desert climate [J].
Al-Ajmi, F ;
Loveday, DL ;
Hanby, VI .
BUILDING AND ENVIRONMENT, 2006, 41 (03) :235-244
[4]   Optimal hydro-thermal characteristics of a porous annular elliptic pipe using response surface method [J].
Al-damook, Amer ;
Azzawi, Itimad D. J. .
INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2021, 128
[5]   The Thermohydraulic Characteristics and Optimization Study of Radial Porous Heat Sinks Using Multi-Objective Computational Method [J].
Al-damook, Amer ;
Azzawi, Itimad D. J. .
JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 2021, 143 (08)
[6]   Multi-objective numerical optimum design of natural convection in different configurations of concentric horizontal annular pipes using different nanofluids [J].
Al-damook, Amer ;
Azzawi, Itimad D. J. .
HEAT AND MASS TRANSFER, 2021, 57 (09) :1543-1557
[7]   Experimental validation and numerical investigation for optimization and evaluation of heat transfer enhancement in double coil heat exchanger [J].
Ali, Senaa Kh ;
Azzawi, Itimad D. J. ;
Khadom, Anees A. .
THERMAL SCIENCE AND ENGINEERING PROGRESS, 2021, 22
[8]   Using Fouggara for Heating and Cooling Buildings in Sahara [J].
Amara, S. ;
Nordell, B. ;
Benyoucef, B. .
IMPACT OF INTEGRATED CLEAN ENERGY ON THE FUTURE OF THE MEDITERRANEAN ENVIRONMENT, 2011, 6 :55-64
[9]   Multi-objective optimum design of porous triangular chamber using RSM [J].
Azzawi, Itimad D. J. ;
Al-damook, Amer .
INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2022, 130
[10]   Enhancement of the Performance Characteristics for Air-Conditioning System by Using Direct Evaporative Cooling in Hot Climates [J].
Eidan, Adel A. ;
Alwan, Kareem J. ;
Alsahlani, Assaad ;
Alfahham, Mohamed .
PROCEEDINGS OF THE 9TH INTERNATIONAL CONFERENCE ON APPLIED ENERGY, 2017, 142 :3998-4003