Selection of Column Dimensions and Gradient Conditions to Maximize the Peak-Production Rate in Comprehensive Off-Line Two-Dimensional Liquid Chromatography Using Monolithic Columns

被引:28
作者
Eeltink, Sebastiaan [1 ]
Dolman, Sebastiaan [2 ]
Vivo-Truyols, Gabriel [3 ]
Schoenmakers, Peter [3 ]
Swart, Remco [2 ]
Ursem, Mario [2 ]
Desmet, Gert [1 ]
机构
[1] Vrije Univ Brussel, Dept Chem Engn, B-1050 Brussels, Belgium
[2] Dionex Chem Corp, NL-1046 AA Amsterdam, Netherlands
[3] Univ Amsterdam, Vant Hoff Inst Mol Sci, NL-1018 WV Amsterdam, Netherlands
关键词
IONIZATION MASS-SPECTROMETRY; CAPILLARY COLUMNS; SEPARATION; PEPTIDES; PROTEINS; CAPACITY; CHEMISTRY; ACIDS; HPLC;
D O I
10.1021/ac101514d
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The peak-production rate (peak capacity per unit time) in comprehensive off-line two-dimensional liquid chromatography (LC/x/LC) was optimized for the separation of peptides using poly(styrene-co-divinylbenzene) monolithic columns in the reversed-phase (RP) mode. A first-dimension ((1)D) separation was performed on a monolithic column operating at a pH of 8, followed by sequential analysis of all the (1)D fractions on a monolithic column operating at a pH of 2. To obtain the highest peak-production rate, effects of column length, gradient duration, and sampling time were examined. RP/x/RP was performed at undersampling conditions using a short 10 min (1)D gradient. The peak-production rate was highest using a 50 mm long (2)D column applying an 8-10 min (2)D gradient time and was almost a factor of two higher than when a 250 mm monolithic column was used. The best way to obtain a higher peak-production rate in off-line LC/x/LC proved to be an increase in the number of (1)D fractions collected. Increasing the (2)D gradient time was less effective. The potential of the optimized RP/x/RP method is demonstrated by analyzing proteomics samples of various complexities. Finally, the trade-off between peak capacity and analysis time is discussed in quantitative terms for both one-dimensional RP gradient-elution chromatography and the off-line two-dimensional (RP/x/RP) approach. At the conditions applied, the RP/x/RP approach provided a higher peak-production rate than the (1)D-LC approach when collecting three (1)D fractions, which corresponds to a total analysis time of 60 min.
引用
收藏
页码:7015 / 7020
页数:6
相关论文
共 24 条
[1]   Effect of first-dimension undersampling on effective peak capacity in comprehensive two-dimensional separations [J].
Davis, Joe M. ;
Stoll, Dwight R. ;
Carr, Peter W. .
ANALYTICAL CHEMISTRY, 2008, 80 (02) :461-473
[2]   Two-dimensional reversed-phase x ion-pair reversed-phase HPLC: An alternative approach to high-resolution peptide separation for shotgun proteome analysis [J].
Delmotte, Nathanael ;
Lasaosa, Maria ;
Tholey, Andreas ;
Heinzle, Ehnar ;
Huber, Christian G. .
JOURNAL OF PROTEOME RESEARCH, 2007, 6 (11) :4363-4373
[3]  
EELTINK S, 2010, J CHROMAT A IN PRESS
[4]   Controlling the surface chemistry and chromatography properties of methyacrylate-ester-based monolithic capillary colums via photografting [J].
Eeltink, Sebastiaan ;
Hilder, Emily F. ;
Geiser, Laurent ;
Svec, Frantisek ;
Frechet, Jean M. J. ;
Rozing, Gerard P. ;
Schoenmakers, Peter J. ;
Kok, Wim Th. .
JOURNAL OF SEPARATION SCIENCE, 2007, 30 (03) :407-413
[5]   Optimizing the peak capacity per unit time in one-dimensional and off-line two-dimensional liquid chromatography for the separation of complex peptide samples [J].
Eeltink, Sebastiaan ;
Dolman, Sebastiaan ;
Swart, Remco ;
Ursem, Mario ;
Schoenmakers, Peter J. .
JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (44) :7368-7374
[6]   1 mm ID poly(styrene-co-divinylbenzene) monolithic columns for high-peak capacity one- and two-dimensional liquid chromatographic separations of intact proteins [J].
Eeltink, Sebastiaan ;
Dolman, Sebastiaan ;
Detobel, Frederik ;
Desmet, Gert ;
Swart, Remco ;
Ursem, Mario .
JOURNAL OF SEPARATION SCIENCE, 2009, 32 (15-16) :2504-2509
[7]   In-line system containing porous polymer monoliths for protein digestion with immobilized pepsin, peptide preconcentration and nano-liquid chromatography separation coupled to electrospray ionization mass spectroscopy [J].
Geiser, Laurent ;
Eeltink, Sebastiaan ;
Svec, Frantisek ;
Frechet, Jean M. J. .
JOURNAL OF CHROMATOGRAPHY A, 2008, 1188 (02) :88-96
[8]   TWO-DIMENSIONAL SEPARATIONS - CONCEPT AND PROMISE [J].
GIDDINGS, JC .
ANALYTICAL CHEMISTRY, 1984, 56 (12) :1258-&
[9]   Implementations of two-dimensional liquid chromatography [J].
Guiochon, Georges ;
Marchetti, Nicola ;
Mriziq, Khaled ;
Shalliker, R. Andrew .
JOURNAL OF CHROMATOGRAPHY A, 2008, 1189 (1-2) :109-168
[10]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY ON CONTINUOUS POLYMER BEDS [J].
HJERTEN, S ;
LIAO, JL ;
ZHANG, R .
JOURNAL OF CHROMATOGRAPHY, 1989, 473 (01) :273-275