Highly Efficient and Robust Grid Connected Photovoltaic System Based Model Predictive Control with Kalman Filtering Capability

被引:32
作者
Ahmed, Mostafa [1 ,2 ]
Abdelrahem, Mohamed [1 ,2 ]
Kennel, Ralph [1 ]
机构
[1] Tech Univ Munich TUM, Inst Elect Drive Syst & Power Elect, D-80333 Munich, Germany
[2] Assiut Univ, Fac Engn, Elect Engn Dept, Assiut 71516, Egypt
关键词
direct switching MPPT; extended Kalman filter; grid connection; model predictive control; MPPT; PV systems; POWER POINT TRACKING; INCREMENTAL CONDUCTANCE MPPT; AFE RECTIFIER; IMPLEMENTATION; ALGORITHM; PERTURB; OBSERVE; DESIGN; PERFORMANCE; SIMULATION;
D O I
10.3390/su12114542
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Renewable energy sources, especially photovoltaic (PV) ones, are gaining more and more interest due to the predicted lack of conventional sources over the coming years. That shortage is not the only concern, as environmental issues add to this concern also. Thus, this study proposes two-stage PV grid connected system, which is supported with extended Kalman filter (EKF) for parameter estimation. In the first stage, maximum power point tracking (MPPT) for the boost converter is accomplished using new MPPT method in which the switching state of the converter is directly generated after the measurement stage, so it is called direct switching MPPT technique. This technique is compared with the conventional finite control set model predictive control (FCS-MPC) method, where the design of the cost function is based on minimizing the error between the reference and the actual current. The reference current is obtained by employing perturb and observe (P&O) method. In the second stage, the two-level inverter is controlled by means of model predictive control (MPC) with reduced computation burden. Further, to overcome the parameter variations, which is a very common problem in MPC applications, an extended Kalman filter is utilized to eliminate the control algorithm's dependency on the parameters by providing an efficient estimation. After the inverter, an RL filter is inserted to guarantee the quality of the currents injected into the grid. Finally, the system is validated using Matlab under different operating conditions of atmospheric variation and parameter changes.
引用
收藏
页数:22
相关论文
共 62 条
[1]   Robust Predictive Control for Direct-Driven Surface-Mounted Permanent-Magnet Synchronous Generators Without Mechanical Sensors [J].
Abdelrahem, Mohamed ;
Hackl, Christoph M. ;
Zhang, Zhenbin ;
Kennel, Ralph .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2018, 33 (01) :179-189
[2]   Fault-Ride through Strategy for Permanent-Magnet Synchronous Generators in Variable-Speed Wind Turbines [J].
Abdelrahem, Mohamed ;
Kennel, Ralph .
ENERGIES, 2016, 9 (12)
[3]  
Abdelrahem M, 2015, 2015 INTERNATIONAL CONFERENCE ON CLEAN ELECTRICAL POWER (ICCEP), P406, DOI 10.1109/ICCEP.2015.7177656
[4]  
Ahmed M., 2020, P PEDSTC2020 11 ANN
[5]   Two-stage micro-grid inverter with high-voltage gain for photovoltaic applications [J].
Ahmed, Mahrous El-Sayed ;
Orabi, Mohamed ;
AbdelRahim, Omar Mohamed .
IET POWER ELECTRONICS, 2013, 6 (09) :1812-1821
[6]   Single-Phase Single-Stage Transformer less Grid-Connected PV System [J].
Alajmi, Bader N. ;
Ahmed, Khaled H. ;
Adam, Grain Philip ;
Williams, Barry W. .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2013, 28 (06) :2664-2676
[7]  
[Anonymous], COMP STUDY MAXIMUM P
[8]   Predictive Direct Power Control of Three-Phase Pulsewidth Modulation (PWM) Rectifier Using Space-Vector Modulation (SVM) [J].
Bouafia, Abdelouahab ;
Gaubert, Jean-Paul ;
Krim, Fateh .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2010, 25 (01) :228-236
[9]   Direct Power Control of an AFE Using Predictive Control [J].
Cortes, Patricio ;
Rodriguez, Jose ;
Antoniewicz, Patrycjusz ;
Kazmierkowski, Marian .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2008, 23 (05) :2516-2523
[10]   Predictive Control in Power Electronics and Drives [J].
Cortes, Patricio ;
Kazmierkowski, Marian P. ;
Kennel, Ralph M. ;
Quevedo, Daniel E. ;
Rodriguez, Jose .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2008, 55 (12) :4312-4324