Feature Extraction and Classification to Diagnose Hypoxic-Ischemic Encephalopathy Patients by Using Susceptibility-Weighted MRI Images

被引:4
作者
Wu, Sisi [1 ]
Mahmoodi, Sasan [1 ]
Darekar, Angela [2 ]
Vollmer, Brigitte [3 ]
Lewis, Emma [2 ]
Liljeroth, Maria [2 ]
机构
[1] Univ Southampton, Elect & Comp Sci, Univ Rd, Southampton SO17 1BJ, Hants, England
[2] Univ Hosp Southampton NHS Fdn Trust, Dept Med Phys, Tremona Rd, Southampton SO16 6YD, Hants, England
[3] Univ Southampton, Clin Neurosci, Clin & Expt Sci, Southampton SO17 1BJ, Hants, England
来源
MEDICAL IMAGE UNDERSTANDING AND ANALYSIS (MIUA 2017) | 2017年 / 723卷
关键词
HIE; SWI; Soft ridge detection; Histogram; Curve fitting; Automatic diagnosis; VESSEL SEGMENTATION; INJURY;
D O I
10.1007/978-3-319-60964-5_46
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
In this paper a method is presented to enable automatic classification of the degree of abnormality of susceptibility-weighted images (SWI) acquired from babies with hypoxic-ischemic encephalopathy (HIE), in order to more accurately predict eventual cognitive and motor outcomes in these infants. SWI images highlight the cerebral venous vasculature and can reflect abnormalities in blood flow and oxygenation, which may be linked to adverse outcomes. A qualitative score based on magnetic resonance imaging (MRI) analyses is assigned to SWIs by specialists to determine the severity of abnormality in an HIE patient. The method allows the detection of image ridges, representing the vessels in SWIs, and the histogram of the ridges grey scales. A curve with only four parameters is fitted to the histograms. These parameters are then used to estimate the SWI abnormality score. The images are classified by using a kNN- and multiple SVM classifiers based on the parameters of the fitting curves. The algorithm is tested on an SWI-MRI dataset consisting of 10 healthy infants and 48 infants with HIE with a range of SWI abnormality scores between 1 and 7. The accuracy of classifying babies with HIE vs. those without (i.e.: healthy controls) using our algorithm with a leave-one-out strategy is measured as 91.38%. Our method is fast and could increase the prognostic value of these scans, thereby improving management of the condition, as well as elucidating the disease mechanisms of HIE.
引用
收藏
页码:527 / 536
页数:10
相关论文
共 21 条
[1]   Leveraging Multiscale Hessian-Based Enhancement With a Novel Exudate Inpainting Technique for Retinal Vessel Segmentation [J].
Annunziata, Roberto ;
Garzelli, Andrea ;
Ballerini, Lucia ;
Mecocci, Alessandro ;
Trucco, Emanuele .
IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2016, 20 (04) :1129-1138
[2]  
Barkovich AJ, 1998, AM J NEURORADIOL, V19, P143
[3]   Analysis of the Valley-Ridge inflection points through the partitioning technique of the Hessian eigenvalue equation [J].
Bofill, Josep Maria ;
Quapp, Wolfgang .
JOURNAL OF MATHEMATICAL CHEMISTRY, 2013, 51 (03) :1099-1115
[4]   Diffusion-weighted MR imaging in the early diagnosis of periventricular leukomalacia [J].
Bozzao, A ;
Di Paolo, A ;
Mazzoleni, C ;
Fasoli, F ;
Simonetti, A ;
Fantozzi, LM ;
Floris, R .
EUROPEAN RADIOLOGY, 2003, 13 (07) :1571-1576
[5]  
Chen D., 2015, MIUA 2015
[6]   Hypoxic-Ischemic Encephalopathy in the Term Infant [J].
Fatemi, All ;
Wilson, Mary Ann ;
Johnston, Michael V. .
CLINICS IN PERINATOLOGY, 2009, 36 (04) :835-+
[7]   Hypoxic-Ischemic Encephalopathy Preface [J].
Friberg, Hans ;
Cronberg, Tobias .
SEMINARS IN NEUROLOGY, 2017, 37 (01) :3-3
[8]   Early identification of hypoxic-ischemic encephalopathy by combination of magnetic resonance (MR) imaging and proton MR spectroscopy [J].
Guo, Lili ;
Wang, Dehang ;
Bo, Genji ;
Zhang, Hui ;
Tao, Weijing ;
Shi, Ying .
EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2016, 12 (05) :2835-2842
[9]  
Hajian-Tilaki K, 2013, CASP J INTERN MED, V4, P627
[10]   Measuring classifier performance: a coherent alternative to the area under the ROC curve [J].
Hand, David J. .