Technical survival of CAPD catheters:: comparison between percutaneous and conventional surgical placement techniques

被引:105
作者
Özener, Ç [1 ]
Bihorac, A [1 ]
Akoglu, E [1 ]
机构
[1] Marmara Univ, Sch Med, Div Nephrol, Istanbul, Turkey
关键词
CAPD; methods of insertion; peritoneal dialysis catheters; technical survival;
D O I
10.1093/ndt/16.9.1893
中图分类号
R3 [基础医学]; R4 [临床医学];
学科分类号
1001 ; 1002 ; 100602 ;
摘要
Background. Percutaneous peritoneal dialysis catheter (PDC) placement is a well-tolerated, rapidly performed bedside procedure that allows a rapid initiation of CAPD. We compared the technical survival of PDCs while comparing the mode of insertion. Methods. We retrospectively reviewed 215 PDCs inserted over a 60-month period in 191 patients on CAPD therapy. Of these, 133 were placed percutaneously by nephrology staff (group P) and 82 were placed using conventional surgical techniques by surgical staff (group S). The total experience accumulated was 4000 patient-months: 2260 patient-months in group P and 1740 patient-months in group S. Results. The incidence of complications in PDCs did not differ between the groups (1 episode/33 patient-months in group P and I episode/29 patient-months in group S). Two episodes of early leakage and 9 episodes of late leakage were observed in group P compared with one early leakage and 4 episodes of late leakage in group S. Of the mechanical complications in group P, 8.86% were due to catheter malfunction, including catheter tip migration and obstruction, compared with 12.63% in group S. The incidence of catheter infections was 1 episode/73 patient-months in group P and I episode/62 patient-months in group S. Significantly more catheters were removed in group S compared with group P (40% vs 16%, P <0.001). One-year and 2-year technical survivals were 90% and 82% in group P, and 73% and 60% in group S (P=0.0032), respectively. Conclusions. Percutaneous bedside placement of PDCs by nephrologists provides a safe and reliable access for peritoneal dialysis.
引用
收藏
页码:1893 / 1899
页数:7
相关论文
共 23 条
  • [1] AKYOL AM, 1990, PERITON DIALYSIS INT, V10, P63
  • [2] COMPLICATIONS WITH PERMANENT PERITONEAL-DIALYSIS CATHETERS - EXPERIENCE WITH 154 PERCUTANEOUSLY PLACED CATHETERS
    ALLON, M
    SOUCIE, JM
    MACON, EJ
    [J]. NEPHRON, 1988, 48 (01): : 8 - 11
  • [3] Apostolidis NS, 1998, PERITON DIALYSIS INT, V18, P424
  • [4] ASH SR, 1994, TXB PERITONEAL DIALY, P315
  • [5] Selective site occupancy exhibited by Cr3+ and Cr6+ incorporated into electrochemically deposited nickel hydroxide films
    Balasubramanian, M
    Melendres, CA
    [J]. ELECTROCHEMICAL AND SOLID STATE LETTERS, 1999, 2 (04) : 167 - 169
  • [6] Peritoneal dialysis access: prospective randomized comparison of single-cuff and double-cuff straight Tenckhoff catheters
    Eklund, B
    Honkanen, E
    Kyllonen, L
    Salmela, K
    Kala, AR
    [J]. NEPHROLOGY DIALYSIS TRANSPLANTATION, 1997, 12 (12) : 2664 - 2666
  • [7] EKLUND BH, 1995, NEPHROL DIAL TRANSPL, V10, P386
  • [8] Euthimiadou A, 1999, ADV PERIT D, V15, P101
  • [9] SURGICAL ASPECTS OF CONTINUOUS AMBULATORY PERITONEAL-DIALYSIS - 3 YEARS EXPERIENCE
    FRANCIS, DMA
    DONNELLY, PK
    VEITCH, PS
    PROUD, G
    TAYLOR, RMR
    RAMOS, JM
    WARD, MK
    WILKINSON, R
    ELLIOTT, RW
    KERR, DNS
    [J]. BRITISH JOURNAL OF SURGERY, 1984, 71 (03) : 225 - 229