Absolute quantification in SPECT

被引:129
作者
Ritt, Philipp [1 ]
Vija, Hans [2 ]
Hornegger, Joachim [3 ]
Kuwert, Torsten [1 ]
机构
[1] Univ Erlangen Nurnberg, Clin Nucl Med, D-91054 Erlangen, Germany
[2] Siemens Med Solut, Hoffman Estates, IL USA
[3] Univ Erlangen Nurnberg, Dept Pattern Recognit, D-91054 Erlangen, Germany
关键词
SPECT; SPECT/CT; Hybrid imaging; Dosimetry; Quantification; Absolute quantification; EMISSION-COMPUTED-TOMOGRAPHY; DISTANCE-DEPENDENT RESOLUTION; SCATTER RESPONSE FUNCTION; X-RAY CT; ATTENUATION CORRECTION; SPATIAL-RESOLUTION; COMPTON-SCATTER; QUANTITATIVE ACCURACY; COMPENSATION; DOSIMETRY;
D O I
10.1007/s00259-011-1770-8
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Single-photon emission computed tomography (SPECT) allows the three-dimensional visualization of radioactivity within the human body and is widely used for clinical purposes. In SPECT, image quality is compromised by several factors including photon attenuation, photon scatter, the partial volume effect, and motion artefacts. These variables also confound the capacity of SPECT to quantify the concentration of radioactivity within given volumes of interest in absolute units, e.g. as kilobecquerels per cubic centimetre. In the last decade, considerable technical progress has been achieved in SPECT image reconstruction, involving, in particular, the development of iterative image reconstruction techniques. Furthermore, hybrid cameras integrating a SPECT camera with an X-ray CT scanner have become commercially available. These systems allow the acquisition of SPECT and CT datasets registered to each other with a high anatomical accuracy. First studies have shown that iterative SPECT image reconstruction techniques incorporating information from SPECT/CT image datasets greatly increase the accuracy of SPECT in quantifying radioactivity concentrations in phantoms and also in humans. This new potential of SPECT may improve not only diagnostic accuracy, but also dosimetry for internal radiotherapy.
引用
收藏
页码:69 / 77
页数:9
相关论文
共 61 条
[1]   Absolute quantitation of iodine-123 epidepride kinetics using single-photon emission tomography:: comparison with carbon-11 epidepride and positron emission tomography [J].
Almeida, P ;
Ribeiro, MJ ;
Bottlaender, M ;
Loc'h, C ;
Langer, O ;
Strul, D ;
Hugonnard, P ;
Grangeat, P ;
Mazière, B ;
Bendriem, B .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1999, 26 (12) :1580-1588
[2]   Attenuation correction of SPECT using X-ray CT on an emission-transmission CT system: Myocardial perfusion assessment [J].
Blankespoor, SC ;
Wu, X ;
Kalki, K ;
Brown, JK ;
Tang, HR ;
Cann, CE ;
Hasegawa, BH .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1996, 43 (04) :2263-2274
[3]   Hybrid Imaging by SPECT/CT and PET/CT: Proven Outcomes in Cancer Imaging [J].
Bockisch, Andreas ;
Freudenberg, Lutz S. ;
Schmidt, Daniela ;
Kuwert, Torsten .
SEMINARS IN NUCLEAR MEDICINE, 2009, 39 (04) :276-289
[4]   Standards for PET Image Acquisition and Quantitative Data Analysis [J].
Boellaard, Ronald .
JOURNAL OF NUCLEAR MEDICINE, 2009, 50 :11S-20S
[5]   Targeted multi-pinhole SPECT [J].
Branderhorst, Woutjan ;
Vastenhouw, Brendan ;
van der Have, Frans ;
Blezer, Erwin L. A. ;
Bleeker, Wim K. ;
Beekman, Freek J. .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 38 (03) :552-561
[7]   A nonlinear spatially variant object-dependent system model for prediction of partial volume effects and scatter in PET [J].
Chen, CH ;
Muzic, RF ;
Nelson, AD ;
Adler, LP .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1998, 17 (02) :214-227
[8]   Automated quality control of emission-transmission misalignment for attenuation correction in myocardial perfusion imaging with SPECT-CT systems [J].
Chen, J ;
Caputlu-Wilson, SF ;
Shi, HC ;
Galt, JR ;
Faber, TL ;
Garcia, EV .
JOURNAL OF NUCLEAR CARDIOLOGY, 2006, 13 (01) :43-49
[9]  
Cherry S. R., 2012, Physics in Nuclear Medicine
[10]  
Da Silva AJ, 2001, J NUCL MED, V42, P772