respiTrack: Patient-specific real-time respiratory tumor motion prediction using magnetic tracking

被引:7
作者
Ozbek, Yusuf [1 ]
Bardosi, Zoltan [1 ]
Freysinger, Wolfgang [1 ]
机构
[1] Med Univ Innsbruck, Innsbruck, Austria
关键词
Real-time tumor tracking; Respiratory motion; Prediction optimization; Magnetic tracking; ACCURACY;
D O I
10.1007/s11548-020-02174-3
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Purpose An intraoperative real-time respiratory tumor motion prediction system with magnetic tracking technology is presented. Based on respiratory movements in different body regions, it provides patient and single/multiple tumor-specific prediction that facilitates the guiding of treatments. Methods A custom-built phantom patient model replicates the respiratory cycles similar to a human body, while the custom-built sensor holder concept is applied on the patient's surface to find optimum sensor number and their best possible placement locations to use in real-time surgical navigation and motion prediction of internal tumors. Automatic marker localization applied to patient's 4D-CT data, feature selection and Gaussian process regression algorithms enable off-line prediction in the preoperative phase to increase the accuracy of real-time prediction. Results Two evaluation methods with three different registration patterns (at fully/half inhaled and fully exhaled positions) were used quantitatively at all internal target positions in phantom: The statical method evaluates the accuracy by stopping simulated breathing and dynamic with continued breathing patterns. The overall root mean square error (RMS) for both methods was between 0.32 +/- 0.06mm and 3.71 +/- 0.79mm. The overall registration RMS error was 0.6 +/- 0.4mm. The best prediction errors were observed by registrations at half inhaled positions with minimum 0.27 +/- 0.02mm, maximum 2.90 +/- 0.72mm. The resulting accuracy satisfies most radiotherapy treatments or surgeries, e.g., for lung, liver, prostate and spine. Conclusion The built system is proposed to predict respiratory motions of internal structures in the body while the patient is breathing freely during treatment. The custom-built sensor holders are compatible with magnetic tracking. Our presented approach reduces known technological and human limitations of commonly used methods for physicians and patients.
引用
收藏
页码:953 / 962
页数:10
相关论文
共 50 条
  • [41] Intraoperative real-time navigation and intraoperative three-dimensional imaging for patient-specific total temporomandibular joint replacement
    Neuhaus, M. -T.
    Zeller, A. -N.
    Jehn, P.
    Lethaus, B.
    Gellrich, N. -C.
    Zimmerer, R. M.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2021, 50 (10) : 1342 - 1350
  • [42] Feasibility of real-time motion tracking using cine MRI during MR-guided radiation therapy for abdominal targets
    Keiper, Timothy D.
    Tai, An
    Chen, Xinfeng
    Paulson, Eric
    Lathuiliere, Fabienne
    Beriault, Silvain
    Hebert, Francois
    Cooper, David T.
    Lachaine, Martin
    Li, X. Allen
    MEDICAL PHYSICS, 2020, 47 (08) : 3554 - 3566
  • [43] Development of a deep learning-based patient-specific target contour prediction model for markerless tumor positioning
    Zhou, Dejun
    Nakamura, Mitsuhiro
    Mukumoto, Nobutaka
    Yoshimura, Michio
    Mizowaki, Takashi
    MEDICAL PHYSICS, 2022, 49 (03) : 1382 - 1390
  • [44] Real-time tumor tracking using sequential kV imaging combined with respiratory monitoring: a general framework applicable to commonly used IGRT systems
    Cho, Byungchul
    Poulsen, Per Rugaard
    Keall, Paul J.
    PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (12) : 3299 - 3316
  • [45] Intrafractional Baseline Shift or Drift of Lung Tumor Motion During Gated Radiation Therapy With a Real-Time Tumor-Tracking System
    Takao, Seishin
    Miyamoto, Naoki
    Matsuura, Taeko
    Onimaru, Rikiya
    Katoh, Norio
    Inoue, Tetsuya
    Sutherland, Kenneth Lee
    Suzuki, Ryusuke
    Shirato, Hiroki
    Shimizu, Shinichi
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 94 (01): : 172 - 180
  • [46] Improving the accuracy of motion quantification using area detector computed tomography for real-time tumor-tracking irradiation in stereotactic ablative radiotherapy
    Suzuki, Kentaro
    Usui, Keisuke
    Sasai, Keisuke
    MEDICAL DOSIMETRY, 2022, 47 (02) : 166 - 172
  • [47] Real-time prediction and gating of respiratory motion in 3D space using extended Kalman filters and Gaussian process regression network
    Bukhari, W.
    Hong, S-M
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (05) : 1947 - 1967
  • [48] Incorporating system latency associated with real-time target tracking radiotherapy in the dose prediction step
    Roland, Teboh
    Mavroidis, Panayiotis
    Shi, Chengyu
    Papanikolaou, Nikos
    PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (09) : 2651 - 2668
  • [49] An adaptive fuzzy prediction model for real time tumor tracking in radiotherapy via external surrogates
    Torshabi, Ahmad Esmaili
    Riboldi, Marco
    Fooladi, Abbas Ali Imani
    Mosalla, Seyed Mehdi Modarres
    Baroni, Guido
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2013, 14 (01): : 102 - 114
  • [50] Stereotactic Neurosurgical Robotics With Real-Time Patient Tracking: A Cadaveric Study
    Robertson, Faith C.
    Wu, Kyle C.
    Sha, Raahil M.
    Amich, Jose M.
    Lal, Avinash
    Lee, Benjamin H.
    Kirollos, Ramez W.
    Chen, Min Wei
    Gormley, William B.
    OPERATIVE NEUROSURGERY, 2022, 22 (06) : 425 - 432