respiTrack: Patient-specific real-time respiratory tumor motion prediction using magnetic tracking

被引:7
|
作者
Ozbek, Yusuf [1 ]
Bardosi, Zoltan [1 ]
Freysinger, Wolfgang [1 ]
机构
[1] Med Univ Innsbruck, Innsbruck, Austria
关键词
Real-time tumor tracking; Respiratory motion; Prediction optimization; Magnetic tracking; ACCURACY;
D O I
10.1007/s11548-020-02174-3
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Purpose An intraoperative real-time respiratory tumor motion prediction system with magnetic tracking technology is presented. Based on respiratory movements in different body regions, it provides patient and single/multiple tumor-specific prediction that facilitates the guiding of treatments. Methods A custom-built phantom patient model replicates the respiratory cycles similar to a human body, while the custom-built sensor holder concept is applied on the patient's surface to find optimum sensor number and their best possible placement locations to use in real-time surgical navigation and motion prediction of internal tumors. Automatic marker localization applied to patient's 4D-CT data, feature selection and Gaussian process regression algorithms enable off-line prediction in the preoperative phase to increase the accuracy of real-time prediction. Results Two evaluation methods with three different registration patterns (at fully/half inhaled and fully exhaled positions) were used quantitatively at all internal target positions in phantom: The statical method evaluates the accuracy by stopping simulated breathing and dynamic with continued breathing patterns. The overall root mean square error (RMS) for both methods was between 0.32 +/- 0.06mm and 3.71 +/- 0.79mm. The overall registration RMS error was 0.6 +/- 0.4mm. The best prediction errors were observed by registrations at half inhaled positions with minimum 0.27 +/- 0.02mm, maximum 2.90 +/- 0.72mm. The resulting accuracy satisfies most radiotherapy treatments or surgeries, e.g., for lung, liver, prostate and spine. Conclusion The built system is proposed to predict respiratory motions of internal structures in the body while the patient is breathing freely during treatment. The custom-built sensor holders are compatible with magnetic tracking. Our presented approach reduces known technological and human limitations of commonly used methods for physicians and patients.
引用
收藏
页码:953 / 962
页数:10
相关论文
共 50 条
  • [31] Adaptive dMLC gating radiotherapy based on real-time motion tracking
    Zhou, Zhengdong
    Chen, Yuanhua
    Yu, Zili
    Dongnan Daxue Xuebao (Ziran Kexue Ban)/Journal of Southeast University (Natural Science Edition), 2014, 44 (05): : 917 - 923
  • [32] Online monitoring and error detection of real-time tumor displacement prediction accuracy using control limits on respiratory surrogate statistics
    Malinowski, Kathleen
    McAvoy, Thomas J.
    George, Rohini
    Dieterich, Sonja
    D'Souza, Warren D.
    MEDICAL PHYSICS, 2012, 39 (04) : 2042 - 2048
  • [33] Alternative fiducial markers for Vero real-time tumor tracking radiotherapy: A phantom study
    Shin-Hyung Park
    Jae-Chul Kim
    Sung Joon Kim
    Journal of the Korean Physical Society, 2016, 69 : 1700 - 1704
  • [34] Alternative fiducial markers for Vero real-time tumor tracking radiotherapy: A phantom study
    Park, Shin-Hyung
    Kim, Jae-Chul
    Kim, Sung Joon
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2016, 69 (11) : 1700 - 1704
  • [35] Robust real-time 3D respiratory motion detection using time-of-flight cameras
    Jochen Penne
    Christian Schaller
    Joachim Hornegger
    Torsten Kuwert
    International Journal of Computer Assisted Radiology and Surgery, 2008, 3 : 427 - 431
  • [36] Real-time tumor motion monitoring and PTV margin determination in lung SBRT treatment
    Liang, Zhiwen
    Yang, Jing
    Liu, Hongyuan
    Yin, Zhongyuan
    Zhang, Sheng
    Peng, Hao
    Wu, Gang
    ACTA ONCOLOGICA, 2019, 58 (12) : 1786 - 1789
  • [37] Robust real-time 3D respiratory motion detection using time-of-flight cameras
    Penne, Jochen
    Schaller, Christian
    Hornegger, Joachim
    Kuwert, Torsten
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2008, 3 (05) : 427 - 431
  • [38] Real-Time Respiratory Motion Correction for Simultaneous PET-MR Using an MR-Derived Motion Model
    King, A. P.
    Tsoumpas, C.
    Buerger, C.
    Schulz, V.
    Marsden, P.
    Schaeffter, T.
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 3589 - 3594
  • [39] Verification of MLC based real-time tumor tracking using an electronic portal imaging device
    Han-Oh, Sarah
    Yi, Byong Yong
    Lerma, Fritz
    Berman, Barry L.
    Gui, Minzhi
    Yu, Cedric
    MEDICAL PHYSICS, 2010, 37 (06) : 2435 - 2440
  • [40] Real-Time Tumor Tracking for Four-Dimensional Computed Tomography Using SQUID Magnetometers
    McGary, John E.