Failures in Single Extra-Short Implants (≤ 6 mm): A Systematic Review and Meta-analysis

被引:18
作者
Badaro, Mauricio Malheiros [1 ]
Marin, Danny Omar Mendoza [1 ]
Pauletto, Patricia [2 ]
Goncalves, Thais Marques Simek Vega [1 ]
Porporatti, Andre Luis [1 ]
Canto, Graziela De Luca [2 ]
机构
[1] Univ Fed Santa Catarina, Dept Dent, Florianopolis, SC, Brazil
[2] Univ Fed Santa Catarina, Brazilian Ctr Evidence Based Res, Dept Dent, Florianopolis, SC, Brazil
关键词
dental implants; meta-analysis; short implants; single crowns; systematic review; SINUS FLOOR ELEVATION; SHORT DENTAL IMPLANTS; RANDOMIZED CONTROLLED MULTICENTER; MODERATELY ROUGH-SURFACE; CROWN HEIGHT SPACE; 6-MM IMPLANTS; POSTERIOR MAXILLA; STRESS-DISTRIBUTION; LONGER IMPLANTS; SURVIVAL RATES;
D O I
10.11607/jomi.8689
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The aim of this systematic review with meta-analysis was to compare the survival rate of single crowns supported by extra-short implants (<= 6 mm) to those supported by conventional implants, with or without previous maxillary sinus augmentation. The proportion of failures was described according to the type of complication and follow-up periods. Materials and Methods: Randomized and prospective clinical trials were selected from six databases and gray literature. The risk of bias was evaluated by Joanna Briggs Institute Critical Appraisal Checklist, and the certainty of the evidence was analyzed with Grading of Recommendations Assessment, Development, and Evaluation. Meta-analyses were processed with RevMan and MedCalc Statistical Software. Results: Single crowns supported by extra-short implants had a similar risk of failure to those supported by conventional implants, regardless of previous maxillary sinus augmentation (P > .05). Overall failure proportion of extra-short implants was 5.19%, but it varied according to follow-up (1.18% before loading, 1.56% at 12 months, 1.20% at 24 months, 2.10% at 48 months). Biologic failure complications were 37.90% for bleeding on probing, 22.45% for peri-implantitis, and 11.29% for infection. Prosthodontics failure complications were 14.88% for abutment failures and 14.73% for prosthetic screw loosening. Considering the risk of bias, most studies were classified at moderate risk. Conclusion: The risk of failure of single crowns supported by extra-short implants is similar to those supported by conventional implants, regardless of previous maxillary sinus augmentation or follow-up period. The most frequent biologic and prosthetic complications were bleeding on probing and abutment failures, respectively. Int J Oral Maxillofac Implants 2021;36:669-689. doi: 10.11607/jomi.8689
引用
收藏
页码:669 / +
页数:24
相关论文
共 60 条
[1]   Dental Implant Length and Diameter: A Proposed Classification Scheme [J].
Al-Johany, Sulieman S. ;
Al Amri, Mohammad D. ;
Alsaeed, Suliman ;
Alalola, Bassam .
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2017, 26 (03) :252-260
[2]   Primary and Secondary Stability of Single Short Implants [J].
Alonso, Fernando R. ;
Triches, Diego F. ;
Mezzomo, Luis A. M. ;
Teixeira, Eduardo R. ;
Shinkai, Rosemary S. A. .
JOURNAL OF CRANIOFACIAL SURGERY, 2018, 29 (06) :E548-E551
[3]   Short implants (5-8 mm) vs. long implants in augmented bone and their impact on peri-implant bone in maxilla and/or mandible: Systematic review [J].
Amine, M. ;
Guelzim, Y. ;
Benfaida, S. ;
Bennani, A. ;
Andoh, A. .
JOURNAL OF STOMATOLOGY ORAL AND MAXILLOFACIAL SURGERY, 2019, 120 (02) :133-142
[4]  
Andersen E, 2001, INT J ORAL MAX IMPL, V16, P217
[5]   Implant Survival and Crestal Bone Loss Around Extra-Short Implants Supporting a Fixed Denture: The Effect of Crown Height Space, Crown-to-Implant Ratio, and Offset Placement of the Prosthesis [J].
Anitua, Eduardo ;
Hamdan Alkhraist, Mohammad ;
Pinas, Laura ;
Begona, Leire ;
Orive, Gorka .
INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2014, 29 (03) :682-689
[6]   A 5-year prospective clinical trial on short implants (6mm) for single tooth replacement in the posterior maxilla: immediate versus delayed loading [J].
Ayna, Mustafa ;
Wessing, Bastian ;
Gutwald, Ralf ;
Neff, Andreas ;
Ziebart, Thomas ;
Acil, Yahya ;
Wiltfang, Joerg ;
Guelses, Aydin .
ODONTOLOGY, 2019, 107 (02) :244-253
[7]   Short (6-mm) dental implants versus sinus floor elevation and placement of longer (10-mm) dental implants: a randomized controlled trial with a 3-year follow-up [J].
Bechara, Souheil ;
Kubilius, Ricardas ;
Veronesi, Giovanni ;
Pires, Jefferson T. ;
Shibli, Jamil A. ;
Mangano, Francesco G. .
CLINICAL ORAL IMPLANTS RESEARCH, 2017, 28 (09) :1097-1107
[8]   A systematic review of the incidence of biological and technical complications in implant dentistry reported in prospective longitudinal studies of at least 5 years [J].
Berglundh, T ;
Persson, L ;
Klinge, B .
JOURNAL OF CLINICAL PERIODONTOLOGY, 2002, 29 :197-212
[9]   Effect of increased crown height on stress distribution in short dental implant components and their surrounding bone: A finite element analysis [J].
Bulaqi, Haddad Arabi ;
Mashhadi, Mahmoud Mousavi ;
Safari, Hamed ;
Samandari, Mohammad Mahdi ;
Geramipanah, Farideh .
JOURNAL OF PROSTHETIC DENTISTRY, 2015, 113 (06) :548-557
[10]   Short Implants (5 to 8 mm) Versus Longer Implants (&gt;8 mm) with Sinus Lifting in Atrophic Posterior Maxilla: A Meta-Analysis of RCTs [J].
Fan, Tengfei ;
Li, Yicun ;
Deng, Wei-Wei ;
Wu, Tianfu ;
Zhang, Wenfeng .
CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2017, 19 (01) :207-215