Occipitocervical fusion combined with 3-dimensional navigation and 3-dimensional printing technology for the treatment of atlantoaxial dislocation with basilar invagination: A case report

被引:10
|
作者
Yuan, Tianyang [1 ]
Jia, Guoliang [1 ]
Yang, Lili [1 ]
Xu, Derui [1 ]
Zhang, Jun [1 ]
Liu, Qinyi [1 ]
机构
[1] Jilin Univ, Hosp 2, Dept Orthopaed, 218 Ziqiang St, Changchun 130000, Jilin, Peoples R China
关键词
3D navigation system; 3D print model; basilar invagination; occipitocervical fusion; DISTRACTION; REDUCTION; FIXATION; DECOMPRESSION; SCREW;
D O I
10.1097/MD.0000000000018983
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction:Basilar invagination (BI) is a common deformity in the occipitocervical region. The traditional surgical method of BI is direct transoral decompression followed by posterior decompression and fixation. Posterior-only decompression and fixation have achieved good efficacy in the treatment of BI in recent years, but complications are common due to the operation in the upper cervical vertebra and the medulla oblongata region. Moreover, posterior-only occipitocervical fusion combined with an intraoperative 3-dimensional (3D) navigation system is relatively rare, and reports of this procedure combined with 3D printing technology have not been published. We present a case of BI treated with posterior-only occipitocervical fusion combined with 3D printing technology and 3D navigation system to reduce the risk of surgical complications.Patient Concerns:A 55-year-old patient with a history of neck pain and numbness of the extremities for 6 years developed a walking disorder for 1 year.Diagnoses:Atlantoaxial dislocation with BI.Interventions:The patient underwent posterior-only occipitocervical fusion combined with intraoperative 3D navigation system and 3D printing technology.Outcomes:The patient's walking disorder was resolved and he was able to walk approximately 100 m by himself when he was allowed to get up and move around with the help of a neck brace. At 6 months postoperatively, the patient reported that the numbness of the limbs was reduced, and he could walk >500 m by himself.Conclusion:Occipitocervical fusion is one of the established techniques for the treatment of BI. The biggest advantage of the 2 technologies was that it ensured precise implant placement. The advantages of intraoperative 3D navigation systems are as follows: real-time intraoperative monitoring of the angle and depth of implant placement; the best nailing point can be determined at the time of implantation, rather than according to the operator's previous experience; and the extent of screw insertion is visible to the naked eye, rather than being dependent on the "hand feel" of the surgeon. At the same time, the 3D printing technology can be applied to clarify the relationship between blood vessels and bone around the implant to minimize injury to important structures during implantation.
引用
收藏
页数:6
相关论文
共 36 条
  • [1] Combined 3-dimensional printing model and 3-dimensional fluoroscopic navigation to assist C2 pedicle screw insertion A case report
    Xu, Hao-Tian
    Zheng, Shuang
    Dong, Rong-Peng
    Yu, Tong
    Zhao, Jian-Wu
    MEDICINE, 2020, 99 (43) : E21838
  • [2] Occipitocervical fusion with relief of odontoid invagination: atlantoaxial distraction method using cylindrical titanium cage for basilar invagination-case report
    Yoshizumi, Tetsuya
    Murata, Hidetoshi
    Ikenishi, Yuriko
    Sato, Mitsuru
    Takase, Hajime
    Tateishi, Kensuke
    Nakanowatari, Satoshi
    Suenaga, Jun
    Kawahara, Nobutaka
    NEUROSURGICAL REVIEW, 2014, 37 (03) : 519 - 525
  • [3] Occipitocervical fusion combining intra-operative skull traction with posterior instrumented reduction for the treatment of basilar invagination with atlantoaxial dislocation
    Xi, Yongming
    Zhang, Xu
    Yuan, Shilong
    Cao, Jin
    Wang, Dechun
    Ma, Jinfeng
    Ren, Xianfeng
    Hu, Yougu
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2016, 9 (06): : 9101 - 9107
  • [4] Occipitocervical fusion with relief of odontoid invagination: atlantoaxial distraction method using cylindrical titanium cage for basilar invagination—case report
    Tetsuya Yoshizumi
    Hidetoshi Murata
    Yuriko Ikenishi
    Mitsuru Sato
    Hajime Takase
    Kensuke Tateishi
    Satoshi Nakanowatari
    Jun Suenaga
    Nobutaka Kawahara
    Neurosurgical Review, 2014, 37 : 519 - 525
  • [5] Computational 3-dimensional dislocation elastodynamics
    Cui, Yinan
    Po, Giacomo
    Pellegrini, Yves-Patrick
    Lazar, Markus
    Ghoniem, Nasr
    JOURNAL OF THE MECHANICS AND PHYSICS OF SOLIDS, 2019, 126 : 20 - 51
  • [6] Application of 3-dimensional printing technology combined with guide plates for thoracic spinal tuberculosis
    Wang, Yifan
    Shi, Shiyuan
    Zheng, Qi
    Jin, Yanghui
    Dai, Yingjie
    MEDICINE, 2021, 100 (06) : E24636
  • [7] A device for three-dimensional quantitative assessment and alignment of C1-2 vertebrae during posterior distraction and fusion technique for atlantoaxial dislocation and/or basilar invagination
    Karthik, P. B.
    Sardhara, Jayesh
    Tiwari, Nachiketa
    Behari, Sanjay
    NEUROLOGY INDIA, 2018, 66 (01) : 181 - 187
  • [8] Mandibular reconstruction using stereolithographic 3-dimensional printing modeling technology
    Cohen, Adir
    Laviv, Amir
    Berman, Phillip
    Nashef, Rizan
    Abu-Tair, Jawad
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2009, 108 (05): : 661 - 666
  • [9] Surgical treatment for upper cervical deformity with atlantoaxial joint dislocation using individualized 3D printing occipitocervical fusion instrument A case report and literature review
    Niu, Guoqi
    Chen, Hui
    Liu, Lutan
    Zhou, Gong
    Zhou, Qiankun
    Li, Chao
    Dai, Jianhao
    Nie, Hu
    Bai, Jianzhong
    Zhang, Jingquan
    MEDICINE, 2021, 100 (12) : E25202
  • [10] Sacroiliac Joint Treatment Personalized to Individual Patient Anatomy Using 3-Dimensional Navigation
    Kleck, Christopher J.
    Perry, James M.
    Burger, Evalina L.
    Cain, Christopher M. J.
    Milligan, Kenneth
    Patel, Vikas V.
    ORTHOPEDICS, 2016, 39 (02) : 89 - 94