Modeling of concrete cracking due to corrosion process of reinforcement bars

被引:77
作者
Bossio, Antonio [1 ]
Monetta, Tullio [1 ]
Bellucci, Francesco [1 ]
Lignola, Gian Piero [2 ]
Prota, Andrea [2 ]
机构
[1] Univ Naples Federico II, Dept Chem Engn Mat & Prod, I-80125 Naples, Italy
[2] Univ Naples Federico II, Dept Struct Engn & Architecture, I-80125 Naples, Italy
关键词
Corrosion; Reinforcement; Modeling; Degradation; COVER-CRACKING; IMPRESSED CURRENT; STEEL CORROSION; MECHANICAL-PROPERTIES; REBAR CORROSION; SERVICE LIFE; RUST LAYER; PREDICTION; INTERFACE;
D O I
10.1016/j.cemconres.2015.01.010
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The reinforcement corrosion in Reinforced Concrete (RC) is a major reason of degradation for structures and infrastructures throughout the world leading to their premature deterioration before design life was attained. The effects of corrosion of reinforcement are: (i) the reduction of the cross section of the bars, and (ii) the development of corrosion products leading to the appearance of cracks in the concrete cover and subsequent cover spalling. Due to their intrinsic complex nature, these issues require an interdisciplinary approach involving both material science and structural design knowledge also in terms on International and National codes that implemented the concept of durability and service life of structures. In this paper preliminary FEM analyses were performed in order to simulate pitting corrosion or general corrosion aimed to demonstrate the possibility to extend the results obtained for a cylindrical specimen, reinforced by a single bar, to more complex RC members in terms of geometry and reinforcement. Furthermore, a mechanical analytical model to evaluate the stresses in the concrete surrounding the reinforcement bars is proposed. In addition, a sophisticated model is presented to evaluate the non-linear development of stresses inside concrete and crack propagation when reinforcement bars start to corrode. The relationships between the cracking development (mechanical) and the reduction of the steel section (electrochemical) are provided. Finally, numerical findings reported in this paper were compared to experimental results available in the literature and satisfactory agreement was found. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:78 / 92
页数:15
相关论文
共 54 条
[2]   COVER CRACKING AS A FUNCTION OF BAR CORROSION .1. EXPERIMENTAL TEST [J].
ANDRADE, C ;
ALONSO, C ;
MOLINA, FJ .
MATERIALS AND STRUCTURES, 1993, 26 (162) :453-464
[3]  
[Anonymous], P EURO C 2003 COMP M
[4]   Environmental effects on cover cracking due to corrosion [J].
Balafas, I. ;
Burgoyne, C. J. .
CEMENT AND CONCRETE RESEARCH, 2010, 40 (09) :1429-1440
[5]  
Bazant Z.P., 1983, MATER CONSTRUCC, V155
[6]  
BAZANT ZP, 1979, J STRUCT DIV-ASCE, V105, P1137
[7]   CATHODIC PROTECTION OF NEW AND OLD REINFORCED-CONCRETE STRUCTURES [J].
BERTOLINI, L ;
BOLZONI, F ;
CIGADA, A ;
PASTORE, T ;
PEDEFERRI, P .
CORROSION SCIENCE, 1993, 35 (5-8) :1633-1639
[8]   Corrosion-induced bond strength degradation in reinforced concrete - Analytical and empirical models [J].
Bhargava, Kapilesh ;
Ghosh, A. K. ;
Mori, Yasuhiro ;
Ramanujam, S. .
NUCLEAR ENGINEERING AND DESIGN, 2007, 237 (11) :1140-1157
[9]   Model for cover cracking due to rebar corrosion in RC structures [J].
Bhargava, Kapilesh ;
Ghosh, A. K. ;
Mori, Yasuhiro ;
Ramanujam, S. .
ENGINEERING STRUCTURES, 2006, 28 (08) :1093-1109
[10]   Real-time evolution of electrical resistance in cracking concrete [J].
Boulay, C. ;
Dal Pont, S. ;
Belin, P. .
CEMENT AND CONCRETE RESEARCH, 2009, 39 (09) :825-831