Uric acid; Polymer modified electrode; Sensors; Electrochemistry; GLASSY-CARBON ELECTRODE; SELECTIVE VOLTAMMETRIC METHOD; OVEROXIDIZED POLYPYRROLE FILMS; CHEMICALLY-MODIFIED ELECTRODES; ASCORBIC-ACID; AMPEROMETRIC BIOSENSOR; COMPOSITE ELECTRODES; GOLD NANOPARTICLES; PASTE ELECTRODE; CATALYTIC-OXIDATION;
D O I
10.1002/elan.201000525
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The present review has sought to explore the technological advances that have been made in recent years towards the selective analysis of uric acid and critically evaluate how they could, in fact, be exploited as a basis for a multi analyte sensor incorporating uric acid detection. Numerous strategies have evolved in recent years but these have invariably focused on the manufacture and response characterization of discrete sensors. Various methods of obtaining selective detection such as use of uricase enzymes, nanoparticles, carbon nanotubes, polymers, conducting polymers and MIPs are also discussed along with the clinical relevance of UA determination.
引用
收藏
页码:305 / 320
页数:16
相关论文
共 192 条
[31]   Non-enzymatic disposable test strip for detecting uric acid in whole blood [J].
Chen, Zhencheng ;
Fang, Cheng ;
Qw, Guanzhou ;
He, Jishan ;
Deng, Zhensheng .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2009, 633 (02) :314-318
[32]   Pathogenesis of gout [J].
Choi, HK ;
Mount, DB ;
Reginato, AM .
ANNALS OF INTERNAL MEDICINE, 2005, 143 (07) :499-516
[33]   POLISHABLE MODIFIED CARBON-FIBER COMPOSITE ELECTRODES CONTAINING COPOLYMERS OF VINYLFERROCENE OR VINYLPYRIDINE IN A CROSS-LINKED POLYSTYRENE MATRIX [J].
CREASY, KE ;
SHAW, BR .
ANALYTICAL CHEMISTRY, 1989, 61 (13) :1460-1465
[34]   Acrylonitrile-acrylic acid copolymer membrane imprinted with uric acid for clinical uses [J].
Cristallini, C ;
Ciardelli, G ;
Barbani, N ;
Giusti, P .
MACROMOLECULAR BIOSCIENCE, 2004, 4 (01) :31-38
[35]   Evaluation of the electrochemical characteristics of a poly(vinyl alcohol) poly(acrylic acid) polymer blend [J].
Dasenbrock, CO ;
Ridgway, TH ;
Seliskar, CJ ;
Heineman, WR .
ELECTROCHIMICA ACTA, 1998, 43 (23) :3497-3502
[36]   URIC-ACID IRON-ION COMPLEXES - A NEW ASPECT OF THE ANTIOXIDANT FUNCTIONS OF URIC-ACID [J].
DAVIES, KJA ;
SEVANIAN, A ;
MUAKKASSAHKELLY, SF ;
HOCHSTEIN, P .
BIOCHEMICAL JOURNAL, 1986, 235 (03) :747-754
[37]   Study of the composite electrodes carbon-polyvinyl chloride and carbon-polyvinyl chloride/Nafion by ex situ and in situ methods [J].
Dávila, MM ;
Elizalde, MP ;
Mattusch, J ;
Wennrich, R .
ELECTROCHIMICA ACTA, 2001, 46 (20-21) :3189-3197
[38]   Detection of uric acid with a new type of conducting polymer-based enzymatic sensor by bipotentiostatic technique [J].
Dobay, R ;
Harsányi, G ;
Visy, C .
ANALYTICA CHIMICA ACTA, 1999, 385 (1-3) :187-194
[39]   Amperometric biosensor with physically immobilized glucose oxidase on a PVA cryogel membrane [J].
Doretti, L ;
Ferrara, D ;
Gattolin, P ;
Lora, S .
TALANTA, 1997, 44 (05) :859-866
[40]  
DUTT V V S E, 1974, Analytical Chemistry, V46, P1777, DOI 10.1021/ac60348a041