Electrochemical Detection of Uric Acid in Mixed and Clinical Samples: A Review

被引:204
作者
Lakshmi, Dhana [1 ]
Whitcombe, Michael J. [1 ]
Davis, Frank [1 ]
Sharma, Piyush Sindhu [3 ]
Prasad, Bhim Bali [2 ]
机构
[1] Cranfield Univ, Cranfield MK43 0AL, Beds, England
[2] Banaras Hindu Univ, Analyt Div, Dept Chem, Varanasi 221005, Uttar Pradesh, India
[3] Univ Verona, Dept Biotechnol, I-37100 Verona, Italy
关键词
Uric acid; Polymer modified electrode; Sensors; Electrochemistry; GLASSY-CARBON ELECTRODE; SELECTIVE VOLTAMMETRIC METHOD; OVEROXIDIZED POLYPYRROLE FILMS; CHEMICALLY-MODIFIED ELECTRODES; ASCORBIC-ACID; AMPEROMETRIC BIOSENSOR; COMPOSITE ELECTRODES; GOLD NANOPARTICLES; PASTE ELECTRODE; CATALYTIC-OXIDATION;
D O I
10.1002/elan.201000525
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The present review has sought to explore the technological advances that have been made in recent years towards the selective analysis of uric acid and critically evaluate how they could, in fact, be exploited as a basis for a multi analyte sensor incorporating uric acid detection. Numerous strategies have evolved in recent years but these have invariably focused on the manufacture and response characterization of discrete sensors. Various methods of obtaining selective detection such as use of uricase enzymes, nanoparticles, carbon nanotubes, polymers, conducting polymers and MIPs are also discussed along with the clinical relevance of UA determination.
引用
收藏
页码:305 / 320
页数:16
相关论文
共 192 条
  • [11] An amperometric biosensor for uric acid determination prepared from uricase immobilized in polyaniline-polypyrrole film
    Arslan, Fatma
    [J]. SENSORS, 2008, 8 (09) : 5492 - 5500
  • [12] A poly(3-acetylthiophene) modified glassy carbon electrode for selective voltammetric measurement of uric acid in urine sample
    Aslanoglu, Mehmet
    Kutluay, Aysegul
    Abbasoglu, Sultan
    Karabulut, Serpil
    [J]. CHEMICAL & PHARMACEUTICAL BULLETIN, 2008, 56 (03) : 282 - 286
  • [13] RENAL-FUNCTION IN GOUT .4. ANALYSIS OF 524 GOUTY SUBJECTS INCLUDING LONG-TERM FOLLOW-UP STUDIES
    BERGER, L
    YU, TF
    [J]. AMERICAN JOURNAL OF MEDICINE, 1975, 59 (05) : 605 - 613
  • [14] Discrete analysis of serum uric acid with immobilized uricase and peroxidase
    Bhargava, AK
    Lal, H
    Pundir, CS
    [J]. JOURNAL OF BIOCHEMICAL AND BIOPHYSICAL METHODS, 1999, 39 (03): : 125 - 136
  • [15] STUDY OF ELECTROCHEMICAL OXIDATION OF REDUCED NICOTINAMIDE ADENINE-DINUCLEOTIDE
    BLAEDEL, WJ
    JENKINS, RA
    [J]. ANALYTICAL CHEMISTRY, 1975, 47 (08) : 1337 - 1343
  • [16] Electrochemical sensing with electrodes modified with molecularly imprinted polymer films
    Blanco-López, MC
    Gutiérrez-Fernández, S
    Lobo-Castañón, MJ
    Miranda-Ordieres, AJ
    Tuñón-Blanco, P
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2004, 378 (08) : 1922 - 1928
  • [17] Uric acid is a risk factor for myocardial infarction and stroke - The Rotterdam Study
    Bos, Michiel J.
    Koudstaal, Peter J.
    Hofman, Albert
    Witteman, Jacqueline C. M.
    Breteler, Monique M. B.
    [J]. STROKE, 2006, 37 (06) : 1503 - 1507
  • [18] Nanostructured carbon fiber disk electrodes for sensitive determinations of adenosine and uric acid
    Brajter-Toth, A
    Abou El-Nour, K
    Cavalheiro, ET
    Bravo, R
    [J]. ANALYTICAL CHEMISTRY, 2000, 72 (07) : 1576 - 1584
  • [19] Possibilities and limitations in miniaturized sensor design for uric acid
    Bravo, R
    Hsueh, C
    Jaramillo, A
    Brajter-Toth, A
    [J]. ANALYST, 1998, 123 (07) : 1625 - 1630
  • [20] SIMULTANEOUS DETERMINATION OF URIC-ACID, XANTHINE AND HYPOXANTHINE WITH AN ELECTROCHEMICALLY PRETREATED CARBON-PASTE ELECTRODE
    CAI, X
    KALCHER, K
    NEUHOLD, C
    [J]. FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1994, 348 (10): : 660 - 665