Influence of Lightning Flashover Criterion on the Calculated Lightning withstand Level of ±800kV UHVDC Transmission Lines at High Altitude

被引:16
|
作者
Han, Yongxia [1 ]
Tang, Li [1 ]
Li, Licheng [1 ]
He, Qiuping [1 ]
Hao, Yanpeng [1 ]
Yao, Senjing [2 ]
机构
[1] S China Univ Technol, Sch Elect Power, Guangzhou 510640, Guangdong, Peoples R China
[2] Shenzhen Power Supply Bur Ltd, Shenzhen 518000, Peoples R China
关键词
Lightning flashover criterion; lightning withstand level; +/- 800 kV UHVDC; leader propagation model; high altitude; SURGE ANALYSIS; TOWER;
D O I
10.1109/TDEI.2014.004537
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The operation experiences of power transmission lines show the lightning outage is still the main part of the total outage rate. So it is very important to calculate the lightning overvoltage across the insulators precisely and evaluate the lightning outage of the transmission lines correctly. Lightning flashover criterion of the insulator/gap is one of the most important factors that influence the precise calculation results of the lightning withstand level of transmission lines. In China, several +/- 800 kV ultra high voltage direct current (UHVDC) power transmission projects have been set up in recent years, and the altitude of the regions that the transmission lines across ranges from 0-3650 m. The paper mainly analyzed the influence of the modelling methods of insulator/gap on the lightning withstand level of +/- 800 kV UHVDC transmission lines by PSCAD/EMTDC program. The compared lightning flashover criteria of insulator/gap include the leader propagation model recommended by CIGRE, the volt/time curve recommended by IEEE and an improved leader propagation model, which is proposed based on the lightning flashover experiments of the +/- 800 kV UHVDC line insulators carried out at an altitude of 2100 m. Meanwhile, the influences of lightning current waveform and insulator structure were also considered and compared. The simulation results show that the calculated back-flashover lightning withstand level is much lower when using the improved leader propagation than that using other flashover criterions in the paper, it is lower under the 2.6/50 mu s double exponential lightning current than that under the 2.0/50 mu s Heidler function lightning current, and it is higher when using V-string than that using I-string insulator. Besides, the influences of the lightning current waveform and the insulator structure on the calculation of shielding failure lightning withstand level are little, but the flashover criterion has obvious influences on the shielding failure lightning withstand level.
引用
收藏
页码:185 / 191
页数:7
相关论文
共 43 条
  • [41] Spatio-temporal Characteristics of the Cloud-to-ground Lightning Activity Along the Transmission Lines in the Tibet High-altitude Area
    Zhao D.
    Gu S.
    Wang Y.
    Li J.
    Wang P.
    Li C.
    Gaodianya Jishu/High Voltage Engineering, 2023, 49 (07): : 3090 - 3101
  • [42] Research on minimum height above ground considering total and ionized field when ± 800kV power lines at the high altitude cross the residential areas
    Guo, Zhijian
    Yu, Jian
    Wang, Xia
    Zhang, Yuexian
    FRONTIERS IN ENERGY RESEARCH, 2023, 11
  • [43] Influences of Wind Deviation on the Ground Resultant Electric Field under Parallel Operation of 750-kV Ultra-High-Voltage Alternating Current and ±800-kV Extra-High-Voltage Direct Current Transmission Lines Passing through Residential Areas in a High-Altitude Area
    Liu H.
    Lang X.
    Li Z.
    Sun Z.
    Huang S.
    Mathematical Problems in Engineering, 2023, 2023