Influence of Lightning Flashover Criterion on the Calculated Lightning withstand Level of ±800kV UHVDC Transmission Lines at High Altitude

被引:16
|
作者
Han, Yongxia [1 ]
Tang, Li [1 ]
Li, Licheng [1 ]
He, Qiuping [1 ]
Hao, Yanpeng [1 ]
Yao, Senjing [2 ]
机构
[1] S China Univ Technol, Sch Elect Power, Guangzhou 510640, Guangdong, Peoples R China
[2] Shenzhen Power Supply Bur Ltd, Shenzhen 518000, Peoples R China
关键词
Lightning flashover criterion; lightning withstand level; +/- 800 kV UHVDC; leader propagation model; high altitude; SURGE ANALYSIS; TOWER;
D O I
10.1109/TDEI.2014.004537
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The operation experiences of power transmission lines show the lightning outage is still the main part of the total outage rate. So it is very important to calculate the lightning overvoltage across the insulators precisely and evaluate the lightning outage of the transmission lines correctly. Lightning flashover criterion of the insulator/gap is one of the most important factors that influence the precise calculation results of the lightning withstand level of transmission lines. In China, several +/- 800 kV ultra high voltage direct current (UHVDC) power transmission projects have been set up in recent years, and the altitude of the regions that the transmission lines across ranges from 0-3650 m. The paper mainly analyzed the influence of the modelling methods of insulator/gap on the lightning withstand level of +/- 800 kV UHVDC transmission lines by PSCAD/EMTDC program. The compared lightning flashover criteria of insulator/gap include the leader propagation model recommended by CIGRE, the volt/time curve recommended by IEEE and an improved leader propagation model, which is proposed based on the lightning flashover experiments of the +/- 800 kV UHVDC line insulators carried out at an altitude of 2100 m. Meanwhile, the influences of lightning current waveform and insulator structure were also considered and compared. The simulation results show that the calculated back-flashover lightning withstand level is much lower when using the improved leader propagation than that using other flashover criterions in the paper, it is lower under the 2.6/50 mu s double exponential lightning current than that under the 2.0/50 mu s Heidler function lightning current, and it is higher when using V-string than that using I-string insulator. Besides, the influences of the lightning current waveform and the insulator structure on the calculation of shielding failure lightning withstand level are little, but the flashover criterion has obvious influences on the shielding failure lightning withstand level.
引用
收藏
页码:185 / 191
页数:7
相关论文
共 43 条
  • [1] Study on the Influencing Factors of Insulator on the Back-Flashover Lightning Withstand Performance of ±800 kV UHVDC Transmission Lines
    Jiang, Wenbo
    Tang, Chunlin
    Zhou, Bo
    MATHEMATICAL PROBLEMS IN ENGINEERING, 2020, 2020
  • [2] Influence of lightning induced voltage on lightning withstand level of transmission lines
    Hou, Mu-Wu
    Zeng, Rong
    He, Jin-Liang
    Power System Technology, 2004, 28 (12) : 46 - 49
  • [3] Transient identification of lightning strokes on ±800 kV UHVDC transmission lines
    Liu, Kezhen
    Shu, Hongchun
    Yu, Jilai
    Tian, Xincui
    Wu, Weimin
    Dianwang Jishu/Power System Technology, 2013, 37 (11): : 3007 - 3014
  • [4] The Identification of Lightning Faults in ±800kV UHVDC Transmission Lines Using S-transform and SVM
    Qin Huai
    Huang Fuzhen
    2013 32ND CHINESE CONTROL CONFERENCE (CCC), 2013, : 3859 - 3864
  • [5] Lightning withstand performance of the Yun-guang ±800 kV UHVDC power transmission line
    Shang, Tao
    Du, Zhong-Dong
    Zhang, Cheng-Wei
    Liu, Xi
    Gaodianya Jishu/High Voltage Engineering, 2008, 34 (10): : 2086 - 2089
  • [6] Shielding failure simulation experiment on the lightning performance of Yunguang ± 800 kV UHVDC transmission lines
    State Grid Electric Power Research Institute, Wuhan 430074, China
    不详
    Gaodianya Jishu, 2008, 10 (2090-2096):
  • [7] Modeling and Simulation of Lightning Electromagnetic Transient and Identification of Shielding Failure and Back Striking in ±800kV UHVDC Transmission Lines Part I: Modeling and simulation of lightning electromagnetic transient
    Shu Hong-chun
    Zhang Guang-bin
    Zhu Zi-zhao
    Zhu Sheng-qiang
    2009 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), VOLS 1-7, 2009, : 3579 - 3582
  • [8] Study on Electrical Transient Protection for ±800kV UHVDC Transmission Lines
    Liu, Kezhen
    Yu, Jilai
    Shu, Hongchun
    Chen, Zhiyu
    2012 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2012,
  • [9] Lightning Flashover Performance Test and Flashover Criterion Study of Insulators in a 110 kV True Type Tower at High Altitude Areas
    Zhang Y.
    Han Y.
    Yang J.
    Ruan Y.
    Liu G.
    Cai H.
    Li L.
    Dianwang Jishu/Power System Technology, 2019, 43 (01): : 340 - 348
  • [10] Lightning current and flashover path measurement on high voltage transmission lines
    Cheng, Yangchun
    Li, Chengrong
    Zhang, Fei
    2006 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, 2006, : 425 - 428