Anesthetic efficacy of the supplemental intraosseous injection of 2%lidocaine with 1:100,000 epinephrine in irreversible pulpits

被引:137
作者
Nusstein, J
Reader, A
Nist, R
Beck, M
Meyers, WJ
机构
[1] USAF, Washington, DC 20330 USA
[2] Ohio State Univ, Coll Dent, Dept Hlth Sci Res, Columbus, OH 43210 USA
[3] Ohio State Univ, Coll Dent, Dept Endodont, Columbus, OH 43210 USA
[4] Ohio State Univ, Coll Dent, Div Endodont, Columbus, OH 43210 USA
关键词
D O I
10.1016/S0099-2399(98)80053-8
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The purpose of this study was to determine the anesthetic efficacy of a supplemental intraosseous injection of 2% lidocaine with 1:100,000 epinephrine in teeth diagnosed with irreversible pulpitis. Fifty-one patients with symptomatic, vital maxillary, and mandibular posterior teeth diagnosed with irreversible pulpitis received conventional infiltrations or inferior alveolar nerve blocks. Pulp testing was used to determine pulpal anesthesia after "clinically successful" injections. Patients who were positive to the pulp tests, or were negative to the pulp tests but felt pain during endodontic access, received an intraosseous injection using 1.8 ml of 2% lidocaine with 1:100,000 epinephrine. The results demonstrated that 42% of the patients who tested negative to the pulp tests reported pain during treatment and required supplemental anesthesia. Eighty-one percent of the mandibular teeth and 12% of maxillary teeth regain pulpal anesthesia. Overall, the Stabident intraosseous injection was found to be 88% successful in gaining total pulpal anesthesia for endodontic therapy. We concluded that, for posterior teeth diagnosed with irreversible pulpitis, the supplemental intraosseous injection of 2% lidocaine (1:100,000 epinephrine) was successful when conventional techniques failed.
引用
收藏
页码:487 / 491
页数:5
相关论文
共 13 条
[1]  
Certosimo AJ, 1996, OPER DENT, V21, P25
[2]   Anesthetic efficacy of the intraosseous injection in maxillary and mandibular teeth [J].
Coggins, R ;
Reader, A ;
Nist, R ;
Beck, M ;
Meyers, WJ .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1996, 81 (06) :634-641
[3]   ENDODONTIC ANESTHESIA IN MANDIBULAR MOLARS - A CLINICAL-STUDY [J].
COHEN, HP ;
CHA, BY ;
SPANGBERG, LSW .
JOURNAL OF ENDODONTICS, 1993, 19 (07) :370-373
[4]   AN EVALUATION OF AN ELECTRIC PULP TESTER AS A MEASURE OF ANALGESIA IN HUMAN VITAL TEETH [J].
DREVEN, LJ ;
READER, A ;
BECK, FM ;
MEYERS, WJ ;
WEAVER, J .
JOURNAL OF ENDODONTICS, 1987, 13 (05) :233-238
[5]   Anesthetic efficacy of the intraosseous injection after an inferior alveolar nerve block [J].
Dunbar, D ;
Reader, A ;
Nist, R ;
Beck, M ;
Meyers, WJ .
JOURNAL OF ENDODONTICS, 1996, 22 (09) :481-486
[6]   THE EFFICACY OF AN INTRAOSSEOUS INJECTION - SYSTEM OF DELIVERING LOCAL-ANESTHETIC [J].
LEONARD, MS .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1995, 126 (01) :81-86
[7]   CARDIOVASCULAR-RESPONSES TO INTRAOSSEOUS INJECTIONS OF PRILOCAINE CONTAINING VASOCONSTRICTORS [J].
LILIENTHAL, B .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1976, 42 (05) :552-558
[8]   CARDIOVASCULAR-RESPONSES TO INTRAOSSEOUS INJECTIONS CONTAINING CATECHOLAMINES [J].
LILIENTHAL, B ;
REYNOLDS, AK .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1975, 40 (05) :574-583
[9]  
Pearce J H, 1976, J Colo Dent Assoc, V54, P25
[10]   Anesthetic efficacy of the intraosseous injection of 2% lidocaine (1:100,000 epinephrine) and 3% mepivacaine in mandibular first molars [J].
Replogle, K ;
Reader, A ;
Nist, R ;
Beck, M ;
Weaver, J ;
Meyers, WJ .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1997, 83 (01) :30-37