Accuracy and reproducibility of virtual edentulous casts created by laboratory impression scan protocols

被引:22
作者
Peng, Lingyan [1 ,2 ,3 ]
Chen, Li [1 ,4 ,5 ,6 ]
Harris, Bryan T. [1 ]
Bhandari, Bikash [7 ]
Morton, Dean [8 ]
Lin, Wei-Shao [1 ]
机构
[1] Univ Louisville, Sch Dent, Dept Oral Hlth & Rehabil, Div Prosthodont, Louisville, KY 40292 USA
[2] Beijing Citident Implant Dent Technol Coll, Beijing, Peoples R China
[3] Beijing Citident Stomatol Hosp, Dept Implantol & Prosthodont, Beijing, Peoples R China
[4] Peking Univ, Sch & Hosp Stomatol, Dept Prosthodont, Beijing, Peoples R China
[5] Natl Engn Lab Digital & Mat Technol Stomatol, Beijing, Peoples R China
[6] Beijing Key Lab Digital Stomatol, Beijing, Peoples R China
[7] Univ Louisville, Sch Publ Hlth & Informat Sci, Dept Bioinformat & Biostat, Louisville, KY 40292 USA
[8] Indiana Univ, Sch Dent, Dept Prosthodont, 1121 W Michigan St, Indianapolis, IN 46202 USA
关键词
COMPUTED-TOMOGRAPHY SCANS; DIGITAL DENTAL MODELS; COMPLETE DENTURES; CAD-CAM; LINEAR MEASUREMENTS; FABRICATION; REHABILITATION; TECHNOLOGIES; PROSTHESES; PATIENT;
D O I
10.1016/j.prosdent.2017.11.024
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of Problem. Although computer-aided design and computer-aided manufacturing (CAD-CAM) complete removable dental prostheses (CRDPs) have gained popularity, conventional impressions are still common for CAD-CAM CRDP treatment. These need to be digitized and converted into virtual edentulous casts with a laboratory impression scan protocol during prosthesis fabrication. How this can best be accomplished is unclear. Purpose. The purpose of this in vitro study was to compare the accuracy and reproducibility of virtual edentulous casts created by a dental laboratory laser scanner and a cone beam computed tomography (CBCT) scanner with a digitized master cast. Material and methods. A master cast was digitized as the virtual reference cast. Ten polyvinyl siloxane impressions were made on the master cast and scanned with the dental laboratory laser scanner and CBCT scanner. The impressions were sprayed with antiglare spray and rescanned. Four groups of virtual study casts (N=40) were created from the impression scans. All virtual study casts and the reference cast were registered with surface-matching software, and the root mean square (RMS) values (representation of overall accuracy) and percentage of measurement data points within 1 standard deviation (SD) of mean RMS values (%, representation of overall reproducibility) among the 4 study groups were measured. Additionally, 95 numeric distance differences (representation of accuracy at each region) were measured in 5 distinct regions: the apex of the denture border, 6 mm from denture border, crest of the ridge, palate, and posterior palatal seal. The repeated-measures ANOVA and post hoc test (t grouping) were used to determine statistical differences (alpha=.05). Results. The laboratory scanner group had a significantly larger RMS value (4.0 +/- 0.3 mu m, P<.001) and smaller percentage of measurement data points within 1 SD of mean RMS value (77.5 +/- 1.0%, P<.001). The RMS values between the CBCT scanner (1.2 +/- 0.3 mu m) and CBCT scanner-spray (1.1 +/- 0.2 mu m) groups were not significantly different (P=.968), and the percentage of measurement data points within 1 SD of mean RMS values (90.1 +/- 1.1% versus 89.5 +/- 0.8%) were also not significantly different (P=.662). The numeric distance differences across 5 regions were affected by the scanning protocols (P<.001). The laboratory scanner and laboratory scanner-spray groups had significantly higher numeric distance differences at the apex of the denture border and crest of the ridge regions (P<.001). Conclusions. The CBCT scanner created more accurate and reproducible virtual edentulous casts, and the antiglare spray only significantly improved the accuracy and reproducibility of virtual edentulous casts created by the dental laboratory laser scanner. The accuracy of the virtual edentulous casts was different across 5 regions and was affected by the scanning protocols.
引用
收藏
页码:389 / 395
页数:7
相关论文
共 37 条
  • [1] Digital Versus Conventional Impressions in Fixed Prosthodontics: A Review
    Ahlholm, Pekka
    Sipila, Kirsi
    Vallittu, Pekka
    Jakonen, Minna
    Kotiranta, Ulla
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2018, 27 (01): : 35 - 41
  • [2] Advancements in CAD/CAM technology: Options for practical implementation
    Alghazzawi, Tariq F.
    [J]. JOURNAL OF PROSTHODONTIC RESEARCH, 2016, 60 (02) : 72 - 84
  • [3] 3-D printing: The new industrial revolution
    Berman, Barry
    [J]. BUSINESS HORIZONS, 2012, 55 (02) : 155 - 162
  • [4] Prospective cohort pilot study of 2-visit CAD/CAM monolithic complete dentures and implant-retained overdentures: Clinical and patient-centered outcomes
    Bidra, Avinash S.
    Farrell, Kimberly
    Burnham, David
    Dhingra, Ajay
    Taylor, Thomas D.
    Kuo, Chia-Ling
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2016, 115 (05) : 578 - 586
  • [5] COMPUTER-AIDED TECHNOLOGY FOR FABRICATING COMPLETE DENTURES: SYSTEMATIC REVIEW OF HISTORICAL BACKGROUND, CURRENT STATUS, AND FUTURE PERSPECTIVES
    Bidra, Avinash S.
    Taylor, Thomas D.
    Agar, John R.
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2013, 109 (06) : 361 - 366
  • [6] Effect of polyvinylsiloxane material and impression handling on the accuracy of digital models
    Camardella, Leonardo Tavares
    Alencar, David Silveira
    Breuning, Hero
    Vilella, Oswaldo de Vasconcellos
    [J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2016, 149 (05) : 634 - 644
  • [7] Emerging applications of bedside 3D printing in plastic surgery
    Chae, Michael P.
    Rozeni, Warren M.
    McMenamin, Paul G.
    Findlay, Michael W.
    Spychal, Robert T.
    Hunter-Smith, David J.
    [J]. FRONTIERS IN SURGERY, 2015, 2
  • [8] Comparison of accuracy and reproducibility of casts made by digital and conventional methods
    Cho, Seok-Hwan
    Schaefer, Oliver
    Thompson, Geoffrey A.
    Guentsch, Arndt
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2015, 113 (04) : 310 - 315
  • [9] Precision of intraoral digital dental impressions with iTero and extraoral digitization with the iTero and a model scanner
    Fluegge, Tabea V.
    Schlager, Stefan
    Nelson, Katja
    Nahles, Susanne
    Metzger, Marc C.
    [J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2013, 144 (03) : 471 - 478
  • [10] The status, challenges, and future of additive manufacturing in engineering
    Gao, Wei
    Zhang, Yunbo
    Ramanujan, Devarajan
    Ramani, Karthik
    Chen, Yong
    Williams, Christopher B.
    Wang, Charlie C. L.
    Shin, Yung C.
    Zhang, Song
    Zavattieri, Pablo D.
    [J]. COMPUTER-AIDED DESIGN, 2015, 69 : 65 - 89