Systematic evaluation of mobile phase additives for the LC-MS characterization of therapeutic proteins

被引:36
作者
Bobaly, Balazs [1 ]
Beck, Alain [3 ]
Fekete, Jeno [1 ]
Guillarme, Davy [2 ]
Fekete, Szabolcs [2 ]
机构
[1] Budapest Univ Technol & Econ, Dept Inorgan & Analyt Chem, H-1111 Budapest, Hungary
[2] Univ Lausanne, Univ Geneva, Sch Pharmaceut Sci, CH-1211 Geneva 4, Switzerland
[3] Ctr Immunol Pierre Fabre, F-74160 St Julien En Genevois, France
关键词
TFA; Formate buffer; RPLC-MS; Therapeutic proteins; Monoclonal antibody; PERFORMANCE LIQUID-CHROMATOGRAPHY; ELECTROSPRAY MASS-SPECTROMETRY; MONOCLONAL-ANTIBODIES; SEPARATION; PEPTIDES; RETENTION; PH; SENSITIVITY; COMPONENTS; RESOLUTION;
D O I
10.1016/j.talanta.2014.12.006
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Trifluoroacetic acid (TFA) is commonly used as mobile phase additive for the analysis of proteins in reversed phase liquid chromatography (RPLC). Due to its interesting features, it provides symmetrical and narrow peak shapes for proteins, but decreases mass spectrometric sensitivity through ion-pairing and spray destabilizing. Since RPLC-MS is an important technique for the characterization of proteins, some alternative MS-compatible mobile phases may be required. The aim of this study was to evaluate various acidic and basic mobile phase additives for the LC-MS analysis of therapeutic proteins possessing molecular weight between 5 and 150 kDa. At the end, 10 mM formate buffer pH 3 was found to be the most promising alternative, since it provided acceptable peak shapes in most cases, together with an average improvement of MS sensitivity by 5-times, compared to TFA. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:60 / 67
页数:8
相关论文
共 29 条
[1]   ENHANCED SENSITIVITY FOR PEPTIDE-MAPPING WITH ELECTROSPRAY LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY IN THE PRESENCE OF SIGNAL SUPPRESSION DUE TO TRIFLUOROACETIC ACID-CONTAINING MOBILE PHASES [J].
APFFEL, A ;
FISCHER, S ;
GOLDBERG, G ;
GOODLEY, PC ;
KUHLMANN, FE .
JOURNAL OF CHROMATOGRAPHY A, 1995, 712 (01) :177-190
[2]   Characterization of Therapeutic Antibodies and Related Products [J].
Beck, Alain ;
Wagner-Rousset, Elsa ;
Ayoub, Daniel ;
Van Dorsselaer, Alain ;
Sanglier-Cianferani, Sarah .
ANALYTICAL CHEMISTRY, 2013, 85 (02) :715-736
[3]   Influence of acid-induced conformational variability on protein separation in reversed phase high performance liquid chromatography [J].
Bobaly, Balazs ;
Toth, Eszter ;
Drahos, Laszlo ;
Zsila, Ferenc ;
Visy, Julia ;
Fekete, Jeno ;
Vekey, Karoly .
JOURNAL OF CHROMATOGRAPHY A, 2014, 1325 :155-162
[4]   Retention of ionizable compounds on high-performance liquid chromatography -: III.: Variation of pK values of acids and pH values of buffers in acetonitrile-water mobile phases [J].
Bosch, E ;
Espinosa, S ;
Rosés, M .
JOURNAL OF CHROMATOGRAPHY A, 1998, 824 (02) :137-146
[5]   Effect of mobile phase additives on peptide retention in reversed-phase chromatography with pellicular and totally porous sorbents [J].
Corradini, D ;
Kalghatgi, K ;
Horvath, C .
JOURNAL OF CHROMATOGRAPHY A, 1996, 728 (1-2) :225-233
[6]   Resolution and identification of the protein components of the photosystem II antenna system of higher plants by reversed-phase liquid chromatography with electrospray-mass spectrometric detection [J].
Corradini, D ;
Huber, CG ;
Timperio, AM ;
Zolla, L .
JOURNAL OF CHROMATOGRAPHY A, 2000, 886 (1-2) :111-121
[7]   Recent advances in peptide separation by multidimensional liquid chromatography for proteome analysis [J].
Di Palma, Serena ;
Hennrich, Marco L. ;
Heck, Albert J. R. ;
Mohammed, Shabaz .
JOURNAL OF PROTEOMICS, 2012, 75 (13) :3791-3813
[8]   High resolution reversed phase analysis of recombinant monoclonal antibodies by ultra-high pressure liquid chromatography column coupling [J].
Fekete, Szabolcs ;
Dong, Michael W. ;
Zhang, Taylor ;
Guillarme, Davy .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2013, 83 :273-278
[9]   Analytical strategies for the characterization of therapeutic monoclonal antibodies [J].
Fekete, Szabolcs ;
Gassner, Anne-Laure ;
Rudaz, Serge ;
Schappler, Julie ;
Guillarme, Davy .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2013, 42 :74-83
[10]   Impact of mobile phase temperature on recovery and stability of monoclonal antibodies using recent reversed-phase stationary phases [J].
Fekete, Szabolcs ;
Rudaz, Serge ;
Veuthey, Jean-Luc ;
Guillarme, Davy .
JOURNAL OF SEPARATION SCIENCE, 2012, 35 (22) :3113-3123