A highly selective electrochemical immunosensor based on conductive carbon black and star PGMA polymer composite material for IL-8 biomarker detection in human serum and saliva

被引:79
作者
Aydin, Muhammet [1 ]
Aydin, Elif Burcu [1 ]
Sezginturk, Mustafa Kemal [2 ]
机构
[1] Namik Kemal Univ, Sci & Technol Res Ctr, Tekirdag, Turkey
[2] Canakkale Onsekiz Mart Univ, Fac Engn, Bioengn Dept, Canakkale, Turkey
关键词
Protein IL 8; Electrochemical impedance spectroscopy; Star-polymer; Poly(glycidyl methacrylate); Conductive Super P-circle Carbon Black; SQUAMOUS-CELL CARCINOMA; LABEL-FREE; IMPEDANCE SPECTROSCOPY; RAMAN-SPECTROSCOPY; CANCER BIOMARKERS; GRAPHENE OXIDE; INTERLEUKIN-8; PROTEIN; BIOSENSOR; DIAGNOSIS;
D O I
10.1016/j.bios.2018.07.010
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A new approach to enhance the electrochemical performance of biosensor was attempted by using Super P (c) carbon black/Star polymer composite material. In this study, we developed an electrochemical IL 8 biosensor by modification with a conductive composite including Super P, polyvinylidene fluoride (PVDF) and star polymer (SPGMA) of disposable ITO electrode surface. The Super P carbon black as carbonaceous material had a high conductivity and was used for the enhancement of electron transfer between electrode surface and electrolyte. Anti-IL 8 antibodies were utilized as biorecognition molecules and bound to epoxy groups of star polymer covalently. The chemical characterization of antibody immobilization on this composite was performed by using Fourier-transform infrared spectroscopy (FTIR) and Raman spectroscopy. The characterizations of stepwise modification of this immunosensor were performed by electrochemical techniques such as Electrochemical Impedance Spectroscopy (EIS), Cyclic Voltammetry (CV) and Single Frequency Impedance (SFI); and morphological techniques such as Scanning Electron Microscopy (SEM) and Atomic Force Microscopy (AFM). Several variables that affect the immunosensor performance were optimized. Under optimum conditions, a wide linear range 0.01-3 pg/mL and low detection limit 3.3 fg/mL were obtained. Super P-star polymer composite modified immunosensor was easy, sensitive, cheap and reliable analytical method for IL 8 detection. The applicability of the proposed immunosensor to determine IL 8 in saliva and serum samples were examined. The results of biosensor and Enzyme-linked Immunosorbent Assay (ELISA) kit were in compatible. Consequently, it was concluded that the electrochemical immunosensor offers a potential approach for IL 8 detection in clinical applications.
引用
收藏
页码:720 / 728
页数:9
相关论文
共 61 条
[11]   Biofunctionalization of magnetic poly(glycidyl methacrylate) microspheres with protein A: Characterization and cellular interactions [J].
Cakmak, Soner ;
Guemuesderelioglu, Menemse ;
Denizli, Adil .
REACTIVE & FUNCTIONAL POLYMERS, 2009, 69 (08) :586-593
[12]   Non-Invasive Breast Cancer Diagnosis through Electrochemical Biosensing at Different Molecular Levels [J].
Campuzano, Susana ;
Pedrero, Maria ;
Pingarron, Jose Manuel .
SENSORS, 2017, 17 (09)
[13]   Fabrication of a highly sensitive disposable immunosensor based on indium tin oxide substrates for cancer biomarker detection [J].
Canbaz, Mehmet Cetin ;
Sezginturk, Mustafa Kemal .
ANALYTICAL BIOCHEMISTRY, 2014, 446 :9-18
[14]  
Chianeh YR, 2014, ASIAN PAC J TROP S1, V4, pS33
[15]   Electrochemical Immunosensors for Detection of Cancer Protein Biomarkers [J].
Chikkaveeraiah, Bhaskara V. ;
Bhirde, Ashwinkumar A. ;
Morgan, Nicole Y. ;
Eden, Henry S. ;
Chen, Xiaoyuan .
ACS NANO, 2012, 6 (08) :6546-6561
[16]   Nanomaterial-based electrochemical immunosensors as advanced diagnostic tools [J].
Dolatabadi, Jafar Ezzati Nazhad ;
de la Guardia, Miguel .
ANALYTICAL METHODS, 2014, 6 (12) :3891-3900
[17]   Xanthan/chitosan gold chip for metal enhanced protein biomarker detection [J].
Domnanich, Patrick ;
Pena, Dacimoneida Brito ;
Preininger, Claudia .
BIOSENSORS & BIOELECTRONICS, 2011, 26 (05) :2559-2565
[18]   Immunodetection of salivary biomarkers by an optical microfluidic biosensor with polyethylenimine-modified polythiophene-C70 organic photodetectors [J].
Dong, Tao ;
Pires, Nuno Miguel Matos .
BIOSENSORS & BIOELECTRONICS, 2017, 94 :321-327
[19]   Enzyme-free electrochemical immunosensor based on methylene blue and the electro-oxidation of hydrazine on Pt nanoparticles [J].
Dutta, Gorachand ;
Nagarajan, Sureshbabu ;
Lapidus, Lisa J. ;
Lillehoj, Peter B. .
BIOSENSORS & BIOELECTRONICS, 2017, 92 :372-377
[20]   Electrochemical Biosensor consisted of conducting polymer layer on gold nanodots patterned Indium Tin Oxide electrode for rapid and simultaneous determination of purine bases [J].
El-Said, Waleed Ahmed ;
Choi, Jeong-Woo .
ELECTROCHIMICA ACTA, 2014, 123 :51-57