Constrained tibial vibration in mice: A method for studying the effects of vibrational loading of bone

被引:17
作者
Christiansen, Blaine A. [1 ,2 ]
Bayly, Philip V. [3 ]
Silva, Matthew J. [1 ,2 ]
机构
[1] Washington Univ, Dept Orthopaed Surg, St Louis, MO 63110 USA
[2] Washington Univ, Dept Biomed Engn, St Louis, MO 63110 USA
[3] Washington Univ, Dept Mech Engn, St Louis, MO 63110 USA
来源
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME | 2008年 / 130卷 / 04期
关键词
vibration; osteoporosis; transmissibility; WBV;
D O I
10.1115/1.2917435
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Vibrational loading can stimulate the formation of new trabecular bone or maintain bone mass. Studies investigating vibrational loading have often used whole-body vibration (WBV) as their loading method. However, WBV has limitations in small animal studies because transmissibility of vibration is dependent on posture. In this study, we propose constrained tibial vibration (CTV) as an experimental method for vibrational loading of mice under controlled conditions. In CTV, the lower leg of an anesthetized mouse is subjected to vertical vibrational loading while supporting a mass. The setup approximates a one degree-of-freedom vibrational system. Accelerometers were used to measure transmissibility of vibration through the lower leg in CTV at frequencies from 20 Hz to 150 Hz. First, the frequency response of transmissibility was quantified in vivo, and dissections were performed to remove one component of the mouse leg (the knee joint, foot, or soft tissue) to investigate the contribution of each component to the frequency response of the intact leg. Next, a finite element (FE) model of a mouse tibia-fibula was used to estimate the deformation of the bone during CTV. Finally, strain gages were used to determine the dependence of bone strain on loading frequency. The in vivo mouse leg in the CTV system had a resonant frequency of 60 Hz for +/- 0.5 G vibration (1.0 G peak to peak). Removing the foot caused the natural frequency of the system to shift from 60 Hz to 70 Hz, removing the soft tissue caused no change in natural frequency, and removing the knee changed the natural frequency from 60 Hz to 90 Hz. By using the FE model, maximum tensile and compressive strains during CTV were estimated to be on the cranial-medial and caudolateral surfaces of the tibia, respectively, and the peak transmissibility and peak cortical strain occurred at the same frequency. Strain gage data confirmed the relationship between peak transmissibility and peak bone strain indicated by the FE model, and showed that the maximum cyclic tibial strain during CTV of the intact leg was 330 +/- 82 mu epsilon and occurred at 60-70 Hz. This study presents a comprehensive mechanical analysis of CTV, a loading method for studying vibrational loading under controlled conditions. This model will be used in future in vivo studies and will potentially become an important tool for understanding the response of bone to vibrational loading.
引用
收藏
页数:6
相关论文
共 16 条
[1]   The effect of varying magnitudes of whole-body vibration on several skeletal sites in mice [J].
Christiansen, Blaine A. ;
Silva, Matthew J. .
ANNALS OF BIOMEDICAL ENGINEERING, 2006, 34 (07) :1149-1156
[2]   Whole-body vibration in the skeleton: Development of a resonance-based testing device [J].
Fritton, JC ;
Rubin, CT ;
Qin, YX ;
McLeod, KJ .
ANNALS OF BIOMEDICAL ENGINEERING, 1997, 25 (05) :831-839
[3]   Low-level Accelerations applied in the absence of weight bearing can enhance trabecular bone formation [J].
Garman, Russell ;
Gaudette, Glenn ;
Donahue, Leah-Rae ;
Rubin, Clinton ;
Judex, Stefan .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2007, 25 (06) :732-740
[4]   Genetic predisposition to low bone mass is paralleled by an enhanced sensitivity to signals anabolic to the skeleton [J].
Judex, S ;
Donahue, LR ;
Rubin, C .
FASEB JOURNAL, 2002, 16 (08) :1280-+
[5]   Low-magnitude mechanical signals that stimulate bone formation in the ovariectomized rat are dependent on the applied frequency but not on the strain magnitude [J].
Judex, Stefan ;
Lei, Xin ;
Han, Daniel ;
Rubin, Clinton .
JOURNAL OF BIOMECHANICS, 2007, 40 (06) :1333-1339
[6]  
KAHN A, 1995, CLIN ORTHOP RELAT R, P69
[7]   Rest insertion combined with high-frequency loading enhances osteogenesis [J].
LaMothe, JM ;
Zernicke, RF .
JOURNAL OF APPLIED PHYSIOLOGY, 2004, 96 (05) :1788-1793
[8]  
Meirovitch L, 2001, FUNDAMENTALS VIBRATI
[9]   Quantity and quality of trabecular bone in the femur are enhanced by a strongly anabolic, noninvasive mechanical intervention [J].
Rubin, C ;
Turner, AS ;
Müller, R ;
Mittra, E ;
McLeod, K ;
Lin, W ;
Qin, YX .
JOURNAL OF BONE AND MINERAL RESEARCH, 2002, 17 (02) :349-357
[10]   Anabolism - Low mechanical signals strengthen long bones [J].
Rubin, C ;
Turner, AS ;
Bain, S ;
Mallinckrodt, C ;
McLeod, K .
NATURE, 2001, 412 (6847) :603-604