A biomechanical comparison of micromotion after ankle fusion using 2 fixation techniques: Intramedullary arthrodesis nail or Ilizarov external fixator

被引:22
作者
Fragomen, Austin T. [1 ]
Meyers, Kathleen N. [1 ]
Davis, Nicole [1 ]
Shu, Hengsheng [2 ]
Wright, Timmothy [1 ]
Rozbruch, S. Robert [1 ]
机构
[1] Hosp Special Surg, New York, NY 10021 USA
[2] Tian Jin Hosp, Tianjin, Peoples R China
关键词
Ilizarov; ankle arthrodesis; biomechanical study; intramedullary nail; biomet arthrodesis nail; limb salvage;
D O I
10.3113/FAI.2008.0334
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: In difficult ankle arthrodesis situations, intramedullary (IM) arthrodesis nails and external fixation are often considered in lieu of standard fusion techniques. The purpose of this study was to compare the amount of micromotion measured across an ankle fusion site stabilized with either an IM nail or with the Ilizarov external fixator. Materials and Methods: The relative bone mineral density of 8 pairs of human cadaveric lower legs was measured by DEXA scanning. One specimen from each pair was randomly assigned to be stabilized with a new generation IM nail and the other with an Ilizarov external fixator. Specimens were tested in compression, rotation, and dorsiflexion. Optical motion capture was used to measure the direct motion occurring at the fusion site. Results: No significant difference was found between the axial displacements (p = 0.94), torsional displacement (p = 0.07), or the dorsiflexion angular displacement (p = 0.28) for the IM rod group and the external fixation group. A weak correlation was found between BMD and displacement. Conclusion: Both the new generation IM nail and the Ilizarov external fixator imparted excellent stability to the fusion site despite a wide range of bone mineral densities. Medialization of the talus, the ability to compress the nail, and the addition of a posterior-to-anterior locking screw were thought to improve the performance of the nail. Clinical Relevance: Both IM nail and Ilizarov external fixation provided excellent fusion site stability. The decision of which implant to use for complex arthrodesis should be dictated by the clinical needs.
引用
收藏
页码:334 / 341
页数:8
相关论文
共 34 条
[1]   Biomechanical comparison of intramedullary nail and blade plate fixation for tibiotalocalcaneal arthrodesis [J].
Alfahd, UA ;
Roth, SE ;
Stephen, D ;
Whyne, CM .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2005, 19 (10) :703-708
[2]   Ankle arthrodesis by compression screws in rheumatoid arthritis -: Primary nonunion in 9/35 patients [J].
Anderson, T ;
Maxander, P ;
Rydholm, U ;
Besjakov, J ;
Carlsson, Å .
ACTA ORTHOPAEDICA, 2005, 76 (06) :884-890
[3]   Tibiotalocalcaneal arthrodesis: A biomechanical assessment of stability [J].
Bennett, GL ;
Cameron, B ;
Njus, G ;
Saunders, M ;
Kay, DB .
FOOT & ANKLE INTERNATIONAL, 2005, 26 (07) :530-536
[4]   A biomechanical comparison of intramedullary nail and crossed lag screw fixation for tibiotalocalcaneal arthrodesis [J].
Berend, ME ;
Glisson, RR ;
Nunley, JA .
FOOT & ANKLE INTERNATIONAL, 1997, 18 (10) :639-643
[5]   Intramedullary rod fixation compared with blade-plate-and-screw fixation for tibiotalocalcaneal arthrodesis: A biomechanical investigation [J].
Chiodo, CP ;
Acevedo, JI ;
Sammarco, VJ ;
Parks, BG ;
Boucher, HR ;
Myerson, MS ;
Schon, LC .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A (12) :2425-2428
[6]  
De Smet K, 2003, Acta Orthop Belg, V69, P42
[7]   Long-term results of arthroscopic ankle arthrodesis [J].
Ferkel, RD ;
Hewitt, M .
FOOT & ANKLE INTERNATIONAL, 2005, 26 (04) :275-280
[8]  
Fragomen AT, 2005, Tech Knee Surg, V4, P173
[9]   A BIOMECHANICAL COMPARATIVE-ANALYSIS OF 2 TECHNIQUES FOR TIBIOTALAR ARTHRODESIS [J].
FRIEDMAN, RL ;
GLISSON, RR ;
NUNLEY, JA .
FOOT & ANKLE INTERNATIONAL, 1994, 15 (06) :301-305
[10]  
Gardner Michael J, 2005, J Orthop Trauma, V19, P597, DOI 10.1097/01.bot.0000174033.30054.5f