Comparison of parallel acquisition techniques generalized autocalibrating partially parallel acquisitions (GRAPPA) and modified sensitivity encoding (mSENSE) in functional MRI (fMRI) at 3T

被引:30
作者
Preibisch, Christine [1 ]
Wallenhorst, Tim [1 ]
Heidemann, Robin [2 ]
Zanella, Friedhelm E. [3 ]
Lanfermann, Heinrich [3 ]
机构
[1] Univ Frankfurt, Brain Imaging Ctr, D-60528 Frankfurt, Germany
[2] Siemens Med Solut, Erlangen, Germany
[3] Hannover Med Sch, Inst Diagnost & Intervent Neuroradiol, Hannover, Germany
关键词
fMRI; parallel imaging; GRAPPA; 0mSENSE; fMRI sensitivity; artifact behavior;
D O I
10.1002/jmri.21191
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate the parallel acquisition techniques, generalized autocalibrating partially parallel acquisitions (GRAPPA) and modified sensitivity encoding (mSENSE), and determine imaging parameters maximizing sensitivity toward functional activation at 3T. Materials and Methods: A total of eight imaging protocols with different parallel imaging techniques (GRAPPA and mSENSE) and reduction factors (R = 1, 2, 3) were compared at different matrix sizes (64 and 128) with respect to temporal noise characteristics, artifact behavior, and sensitivity toward functional activation. Results: Echo planar imaging (EPI) with GRAPPA and a reduction factor of 2 revealed similar image quality and sensitivity than full k-space EPI. A higher incidence of artifacts and a marked sensitivity loss occurred at R = 3. Even though the same eight-channel head coil was used for signal detection in all experiments, GRAPPA generally showed more benign patterns of spatially-varying noise amplification, and mSENSE was also more susceptible to residual unfolding artifacts than GRAPPA. Conclusion: At 3T and a reduction factor of 2, parallel imaging can be used with only little penalty with regard to sensitivity. With our implementation and coil setup the performance of GRAPPA was clearly superior to mSENSE. Thus, it seems advisable to pay special attention to the employed parallel imaging method and its implementation.
引用
收藏
页码:590 / 598
页数:9
相关论文
共 36 条
  • [1] Blaimer Martin, 2004, Top Magn Reson Imaging, V15, P223, DOI 10.1097/01.rmr.0000136558.09801.dd
  • [2] Accelerated parallel imaging for functional imaging of the human brain
    de Zwart, JA
    van Gelderen, P
    Golay, X
    Ikonomidou, VN
    Duyn, JH
    [J]. NMR IN BIOMEDICINE, 2006, 19 (03) : 342 - 351
  • [3] Reduction of gradient acoustic noise in MRI using SENSE-EPI
    de Zwart, JA
    van Gelderen, P
    Kellman, P
    Duyn, JH
    [J]. NEUROIMAGE, 2002, 16 (04) : 1151 - 1155
  • [4] Application of sensitivity-encoded echo-planar imaging for blood oxygen level-dependent functional brain imaging
    de Zwart, JA
    van Gelderen, P
    Kellman, P
    Duyn, JH
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2002, 48 (06) : 1011 - 1020
  • [5] Golay Xavier, 2004, Top Magn Reson Imaging, V15, P255, DOI 10.1097/01.rmr.0000142829.79609.d4
  • [6] Autocalibrated coil sensitivity estimation for parallel imaging
    Griswold, MA
    Breuer, F
    Blaimer, M
    Kannengiesser, S
    Heidemann, RM
    Mueller, M
    Nittka, M
    Jellus, V
    Kiefer, B
    Jakob, PM
    [J]. NMR IN BIOMEDICINE, 2006, 19 (03) : 316 - 324
  • [7] Generalized Autocalibrating Partially Parallel Acquisitions (GRAPPA)
    Griswold, MA
    Jakob, PM
    Heidemann, RM
    Nittka, M
    Jellus, V
    Wang, JM
    Kiefer, B
    Haase, A
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (06) : 1202 - 1210
  • [8] Field-of-view limitations in parallel imaging
    Griswold, MA
    Kannengiesser, S
    Heidemann, RM
    Wang, JM
    Jakob, PM
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2004, 52 (05) : 1118 - 1126
  • [9] Griswold MA, 1999, MAGNET RESON MED, V41, P1236, DOI 10.1002/(SICI)1522-2594(199906)41:6<1236::AID-MRM21>3.0.CO
  • [10] 2-T