Zero Temperature Coefficient Bias in MOS Devices. Dependence on Interface Traps Density, Application to MOS Dosimetry

被引:23
作者
Carbonetto, Sebastian H. [1 ]
Garcia Inza, Mariano A. [1 ]
Lipovetzky, Jose [1 ]
Redin, Eduardo G. [1 ]
Sambuco Salomone, Lucas [1 ]
Faigon, Adrian [1 ,2 ,3 ]
机构
[1] Univ Buenos Aires, Fac Ingn, Dept Fis, Device Phys Microelect Lab, Buenos Aires, DF, Argentina
[2] Univ Buenos Aires, Fac Ingn, INTECIN, Buenos Aires, DF, Argentina
[3] Natl Res Council Argentina CONICET, Buenos Aires, DF, Argentina
关键词
Dosimetry; ionizing radiation sensors; MOS devices; radiation effects; temperature;
D O I
10.1109/TNS.2011.2170430
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper the influence of temperature fluctuations on the response of thick gate oxide metal oxide semiconductor dosimeters is reviewed and the zero temperature coefficient (ZTC) method is evaluated for error compensation. The response of the ZTC current to irradiation is studied showing that the error compensation impoverishes with absorbed dose. Finally, an explanation and analytic expression for the shifts in the ZTC current with irradiation based on the interface traps creation is proposed and verified with experimental data.
引用
收藏
页码:3348 / 3353
页数:6
相关论文
共 22 条
[11]   Total ionizing dose effects in MOS oxides and devices [J].
Oldham, TR ;
McLean, FB .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2003, 50 (03) :483-499
[12]  
ROSENFELD AB, 2007, RADIAT MEAS, V41, P134
[13]  
Sarrabayrouse G, 2008, ELE COM ENG, P26
[14]  
Sarrabayrouse G., 1998, IEEE Instrumentation & Measurement Magazine, V1, P26, DOI 10.1109/5289.685494
[15]  
Sarrabayrouse G., 2010, Proceedings of the 9th WSEAS International Conference on Instrumentation Measurement Circuits and Systems (IMCAS 2010). Instrumentation, Measurement, Circuits and Systems, P38
[16]  
Sarrabayrouse G., 1994, Radioprotection, V29, P557, DOI [10.1051/radiopro/1994006, DOI 10.1051/RADIOPRO/1994006]
[17]  
Sarrabayrouse G., 2009, P 3 INT C SIGN CIRC, P1
[18]   FIELD-DEPENDENCE OF INTERFACE-TRAP BUILDUP IN POLYSILICON AND METAL GATE MOS DEVICES [J].
SHANEYFELT, MR ;
SCHWANK, JR ;
FLEETWOOD, DM ;
WINOKUR, PS ;
HUGHES, KL ;
SEXTON, FW .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1990, 37 (06) :1632-1640
[19]   EVALUATION OF A DUAL BIAS DUAL METAL-OXIDE-SILICON SEMICONDUCTOR FIELD-EFFECT TRANSISTOR DETECTOR AS RADIATION DOSIMETER [J].
SOUBRA, M ;
CYGLER, J ;
MACKAY, G .
MEDICAL PHYSICS, 1994, 21 (04) :567-572
[20]  
Sze S.M., 2013, SEMICONDUCTOR DEVICE