Electrode Potential-Based Coupled Coil Sensor for Remote pH Monitoring

被引:21
作者
Bhadra, Sharmistha [1 ]
Bridges, Greg E. [1 ]
Thomson, Douglas J. [1 ]
Freund, Michael S. [2 ]
机构
[1] Univ Manitoba, Dept Elect & Comp Engn, Winnipeg, MB R3T 5V6, Canada
[2] Univ Manitoba, Dept Chem, Winnipeg, MB R3T 5V6, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Combination electrode; coupled coil; inductive coupling; passive; pH; prototype; resonant frequency; wireless; WIRELESS;
D O I
10.1109/JSEN.2011.2170563
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We present a coupled coil pH sensor for high-resolution remote pH monitoring. The sensor is based on a passive LC coil resonator whose resonant frequency is monitored remotely by measuring the change in impedance of an interrogator coil coupled to the sensor coil. The sensor resonator consists of an inductive coil connected in parallel with a voltage dependent capacitor and a pH combination electrode. When the pH of the contact solution changes, the electrode potential changes the capacitance, and therefore the resonant frequency of the sensor. A linear response with a 0.1 pH resolution is achieved over a 2-12 pH dynamic range at room temperature. The response time of the sensor is demonstrated to be less than 30 s and is limited by the response time of the pH combination electrode. Effects of varying separation distance and temperature change on the sensor's performance are shown. The described sensor technology has potential application for remote pH monitoring in numerous fields such as biomedical sensing, environmental monitoring, industrial and chemical processing, and structural health monitoring.
引用
收藏
页码:2813 / 2819
页数:7
相关论文
共 24 条
[1]  
Ativanichayaphong T., 2007, 2007 IEEE International Conference on RFID, P127, DOI 10.1109/RFID.2007.346160
[2]  
Ativanichayaphong T, 2010, IEEE MTT S INT MICR, P608, DOI 10.1109/MWSYM.2010.5517628
[3]  
Barron JJ., 2005, EFFECTS TEMPERATURE, P1
[4]   A Wireless Passive pH Sensor Based on pH Electrode Potential Measurement [J].
Bhadra, S. ;
Bridges, G. E. ;
Thomson, D. J. ;
Freund, M. S. .
2010 IEEE SENSORS, 2010, :927-930
[5]   In situ measurement of Cl- concentrations and pH at the reinforcing steel/concrete interface by combination sensors [J].
Du, Rong-Gui ;
Hu, Rong-Gang ;
Huang, Ruo-Shuang ;
Lin, Chang-Jian .
ANALYTICAL CHEMISTRY, 2006, 78 (09) :3179-3185
[6]   Assessment of water quality based on multiparameter fiber optic probe [J].
Dybko, A ;
Wróblewski, W ;
Rozniecka, E ;
Pozniak, K ;
Maciejewski, J ;
Romaniuk, R ;
Brzózka, Z .
SENSORS AND ACTUATORS B-CHEMICAL, 1998, 51 (1-3) :208-213
[7]   MEDICAL APPLICATIONS OF SILICON SENSORS [J].
ENGELS, JML ;
KUYPERS, MH .
JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1983, 16 (10) :987-994
[8]   Simultaneous monitoring of pH, CO2 and O-2 using an optical imaging fiber [J].
Ferguson, JA ;
Healey, BG ;
Bronk, KS ;
Barnard, SM ;
Walt, DR .
ANALYTICA CHIMICA ACTA, 1997, 340 (1-3) :123-131
[9]   Investigation of Thick-Film Polyaniline-Based Conductimetric pH Sensors for Medical Applications [J].
Gill, Edric I. ;
Arshak, Arousian ;
Arshak, Khalil ;
Korostynska, Olga .
IEEE SENSORS JOURNAL, 2009, 9 (5-6) :555-562
[10]   A sol-gel based fiber optic sensor for local blood pH measurements [J].
Grant, SA ;
Glass, RS .
SENSORS AND ACTUATORS B-CHEMICAL, 1997, 45 (01) :35-42