Pan-Corneal Endothelial Viability Assessment: Application to Endothelial Grafts Predissected by Eye Banks

被引:55
作者
Pipparelli, Aurelien [1 ,2 ]
Thuret, Gilles [1 ,2 ]
Toubeau, David [3 ]
He, Zhiguo [1 ]
Piselli, Simone [1 ]
Lefevre, Sabine [3 ]
Gain, Philippe [1 ]
Muraine, Marc [3 ,4 ]
机构
[1] Univ St Etienne, Lab Corneal Graft Biol Engn & Imaging, Fac Med, St Etienne, France
[2] Univ Hosp, Dept Ophthalmol, St Etienne, France
[3] Normandy Reg Eye Bank, Rouen, France
[4] Charles Nicolles Hosp, Dept Ophthalmol, Rouen, France
关键词
POSTERIOR LAMELLAR KERATOPLASTY; SPECULAR MICROSCOPY ANCILLARY; DONOR TISSUE VIABILITY; VITAL DYE ASSAY; M-K MEDIUM; ORGAN-CULTURE; CELL DENSITY; EX-VIVO; PENETRATING KERATOPLASTY; OXIDATIVE STRESS;
D O I
10.1167/iovs.10-6641
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. To present an experimental method for determining the viable cell pool of corneal endothelia and its application to assessing predissected endothelial grafts. METHODS. The endothelial cell density (ECD) of five pairs of human organ cultured corneas was determined using a standard counting method with a calibrated image analysis system. A thin posterior graft (30-50 mu m) was manually predissected from a cornea chosen at random. Predissected and control corneas were shipped to the remote center, where standard ECD determination was repeated and was immediately followed by a triple Hoechst/ethidium/calcein labeling coupled with image analysis of the whole graft surface. Numeration of nuclei (H +), dead cells (E +), and total area covered by viable cells (C +) allowed the calculation of viable ECD corresponding to the cell density that the cornea may have after redistribution of viable cells over the whole Descemet surface. RESULTS. The median (range) viable ECD was lower than the standard ECD determined immediately earlier in predissected and control corneas: 1628 (1138-2379) and 2065 (1492-2876) cells/mm(2) (P = 0.043), corresponding to -20% (-1%-38%) and -12% (-3%-26%), respectively (P = 0.08). CONCLUSIONS. Standard counting by eye banks overestimates the actual pool of viable endothelial cells. This may be the main explanation for the initially rapid decrease in ECD universally described in patients after all types of keratoplasty. Early low postoperative ECD may indicate that surgeons graft fewer living cells than the eye banks' ECD let suppose, rather than a massive pre- and postoperative cell death. The novel concept of viable ECD can be useful for assessing all types of corneal processing. (Invest Ophthalmol Vis Sci. 2011;52:6018-6025) DOI:10.1167/iovs.10-6641
引用
收藏
页码:6018 / 6025
页数:8
相关论文
共 73 条
[1]   Endothelial Morphometry by Image Analysis of Corneas Organ Cultured at 31°C [J].
Acquart, Sophie ;
Gain, Philippe ;
Zhao, Min ;
Gavet, Yann ;
Defreyn, Alexandre ;
Piselli, Simone ;
Garraud, Olivier ;
Thuret, Gilles .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (03) :1356-1364
[2]  
Albon J, 2000, INVEST OPHTH VIS SCI, V41, P2887
[3]   Pre-cut donor tissue for Descemet stripping automated keratoplasty: anterior hinged lamella on versus off [J].
Amato, Domenico ;
Oddone, Francesco ;
Nubile, Mario ;
Gisoldi, Rossella Anna Maria Colabelli ;
Villani, Carlo Maria ;
Pocobelli, Augusto .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2010, 94 (04) :519-522
[4]   CORNEAL PRESERVATION USING M-K MEDIUM [J].
AQUAVELLA, JV ;
VANHORN, DL ;
HAGGERTY, CJ .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1975, 80 (05) :791-799
[5]  
BASU PK, 1978, CAN J OPHTHALMOL, V13, P31
[6]   Specular microscopy ancillary study methods for donor endothelial cell density determination of cornea donor study images [J].
Benetz, BA ;
Gal, RL ;
Ruedy, KJ ;
Rice, C ;
Beck, RW ;
Kalajian, AD ;
Lass, JH .
CURRENT EYE RESEARCH, 2006, 31 (04) :319-327
[7]  
BINDER PS, 1978, INVEST OPHTH VIS SCI, V17, P159
[8]   Screening human donor corneas during organ culture for the presence of guttae [J].
Borderie, VM ;
Sabolic, V ;
Touzeau, O ;
Scheer, S ;
Carvajal-Gonzalez, S ;
Laroche, L .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2001, 85 (03) :272-276
[9]   Endothelial keratoplasty: DSEK/DSAEK or DMEK - the thinner the better? [J].
Dapena, Isabel ;
Ham, Lisanne ;
Melles, Gerrit R. J. .
CURRENT OPINION IN OPHTHALMOLOGY, 2009, 20 (04) :299-307
[10]   Comparison of two semiautomated methods for evaluating endothelial cells of eye bank corneas [J].
Deb-Joardar, Nilanjana ;
Thuret, Gilles ;
Zhao, Min ;
Acquart, Sophie ;
Peoc'h, Michel ;
Garraud, Olivier ;
Gain, Philippe .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2007, 48 (07) :3077-3082