Image preprocessing to improve the accuracy and robustness of mutual-information-based automatic image registration in proton therapy

被引:4
|
作者
Hirotaki, Kouta [1 ,2 ]
Moriya, Shunsuke [3 ]
Akita, Tsunemichi [2 ]
Yokoyama, Kazutoshi [2 ]
Sakae, Takeji [3 ]
机构
[1] Univ Tsukuba, Grad Sch Comprehens Human Sci, Doctoral Program Med Sci, Ibaraki 3058577, Japan
[2] Natl Canc Ctr Hosp East, Dept Radiol Technol, Chiba 2778577, Japan
[3] Univ Tsukuba, Fac Med, Ibaraki 3058575, Japan
关键词
Automatic image registration; Image -guided radiotherapy; Mutual information; HEAD; RADIOTHERAPY; SETUP; 2D;
D O I
10.1016/j.ejmp.2022.08.005
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: We propose a method that potentially improves the outcome of mutual-information-based automatic image registration by using the contrast enhancement filter (CEF).Methods: Seventy-six pairs of two-dimensional X-ray images and digitally reconstructed radiographs for 20 head and neck and nine lung cancer patients were analyzed retrospectively. Automatic image registration was performed using the mutual-information-based algorithm in VeriSuite (R). Images were preprocessed using the CEF in VeriSuite (R). The correction vector for translation and rotation error was calculated and manual image registration was compared with automatic image registration, with and without CEF. In addition, the normalized mutual information (NMI) distribution between two-dimensional images was compared, with and without CEF.Results: In the correction vector comparison between manual and automatic image registration, the average differences in translation error were < 1 mm in most cases in the head and neck region. The average differences in rotation error were 0.71 and 0.16 degrees without and with CEF, respectively, in the head and neck region; they were 2.67 and 1.64 degrees, respectively, in the chest region. When used with oblique projection, the average rotation error was 0.39 degrees with CEF. CEF improved the NMI by 17.9 % in head and neck images and 18.2 % in chest images.Conclusions: CEF preprocessing improved the NMI and registration accuracy of mutual-information-based automatic image registration on the medical images. The proposed method achieved accuracy equivalent to that achieved by experienced therapists and it will significantly contribute to the standardization of image registration quality.
引用
收藏
页码:95 / 103
页数:9
相关论文
共 50 条
  • [1] Interpolation Effects on Accuracy of Mutual Information Based Image Registration
    Li, Qi
    Sato, Isao
    Murakami, Yutaka
    2006 IEEE INTERNATIONAL GEOSCIENCE AND REMOTE SENSING SYMPOSIUM, VOLS 1-8, 2006, : 180 - 183
  • [2] Mutual-information-based image to patient re-registration using intraoperative ultrasound in image-guided neurosurgery
    Ji, Songbai
    Wu, Ziji
    Hartov, Alex
    Roberts, David W.
    Paulsen, Keith D.
    MEDICAL PHYSICS, 2008, 35 (10) : 4612 - 4624
  • [3] Automatic image registration by stochastic optimization of mutual information
    Cole-Rhodes, A
    Adenle, A
    2003 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH, AND SIGNAL PROCESSING, VOL III, PROCEEDINGS: IMAGE & MULTIDIMENSIONAL SIGNAL PROCESSING SIGNAL, PROCESSING EDUCATION, 2003, : 313 - 316
  • [4] Automatic medical image registration using mutual information
    Kumagai, Kazuaki
    Sasaki, Takehisa
    Yamaguchi, Keiichiro
    Margaretha, Sulistyoningsih
    Miyake, Masayasu
    Watanuki, Shoichi
    Tashiro, Manabu
    Itoh, Masatoshi
    FUTURE MEDICAL ENGINEERING BASED ON BIONANOTECHNOLOGY, PROCEEDINGS, 2006, : 755 - +
  • [5] Evaluation of a fully automatic medical image registration algorithm based on mutual information
    Tanaćs, Attila
    Kuba, Attila
    Acta Cybernetica, 2003, 16 (02): : 327 - 336
  • [6] Mutual-information-based registration of medical images: A survey
    Pluim, JPW
    Maintz, JBA
    Viergever, MA
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2003, 22 (08) : 986 - 1004
  • [7] Spatially weighted mutual information image registration for image guided radiation therapy
    Park, Samuel B.
    Rhee, Frank C.
    Monroe, James I.
    Sohn, Jason W.
    MEDICAL PHYSICS, 2010, 37 (09) : 4590 - 4601
  • [8] Spatial Weighted Mutual Information for Image Registration in Image Guided Radiation Therapy
    Park, S. B.
    Rhee, F. C.
    Monroe, J. I.
    Sohn, J. W.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [9] Enhanced mutual information based medical image registration
    Pradhan, Smita
    Patra, Dipti
    IET IMAGE PROCESSING, 2016, 10 (05) : 418 - 427
  • [10] A new method for image registration based on mutual information
    Hong, Ming-Jian
    Lü, Jian-Bin
    Yang, Dan
    Mao, You-Li
    Chongqing Daxue Xuebao/Journal of Chongqing University, 2009, 32 (06): : 697 - 700