The Effects of Scanning Speed and Standoff Distance of the Fiber on Dusting Efficiency during Short Pulse Holmium: YAG Laser Lithotripsy

被引:9
作者
Chen, Junqin [1 ]
Li, Daiwei [2 ]
Yu, Wenjun [1 ]
Ma, Zhiteng [1 ]
Li, Chenhang [1 ]
Xiang, Gaoming [1 ]
Wu, Yuan [3 ]
Yao, Junjie [2 ]
Zhong, Pei [1 ]
机构
[1] Duke Univ, Thomas Lord Dept Mech Engn & Mat Sci, Durham, NC 27708 USA
[2] Duke Univ, Dept Biomed Engn, Photoacoust Imaging Lab, Durham, NC 27708 USA
[3] Duke Univ, Med Ctr, Dept Biostat & Bioinformat, Durham, NC 27708 USA
关键词
laser lithotripsy; fiber scanning speed; cavitation; mechanisms of stone dusting; ALUMINUM-GARNET LASER; KIDNEY-STONES; FREQUENCY; FRAGMENTATION; SETTINGS; URETEROSCOPY; CAVITATION; MECHANISM;
D O I
10.3390/jcm11175048
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To investigate the effects of fiber lateral scanning speed across the stone surface (v(fiber)) and fiber standoff distance (SD) on dusting efficiency during short pulse holmium (Ho): YAG laser lithotripsy (LL), pre-soaked BegoStone samples were treated in water using 0.2 J/20 Hz at SD of 0.10 similar to 0.50 mm with v(fiber) in the range of 0 similar to 10 mm/s. Bubble dynamics, pressure transients, and stone damage were analyzed. To differentiate photothermal ablation vs. cavitation damage, experiments were repeated in air, or in water with the fiber tip at 0.25 mm proximity from the ureteroscope end to mitigate cavitation damage. At SD = 0.10 mm, the maximum dusting efficiency was produced at v(fiber) = 3.5 mm/s, resulting in long (17.5 mm), shallow (0.15 mm), and narrow (0.4 mm) troughs. In contrast, at SD = 0.50 mm, the maximum efficiency was produced at v(fiber) = 0.5 mm/s, with much shorter (2.5 mm), yet deeper (0.35 mm) and wider (1.4 mm), troughs. With the ureteroscope end near the fiber tip, stone damage was significantly reduced in water compared to those produced without the ureteroscope. Under clinically relevant v(fiber) (1 similar to 3 mm/s), dusting at SD = 0.5 mm that promotes cavitation damage may leverage the higher frequency of the laser (e.g., 40 to 120 Hz) and, thus, significantly reduces the procedure time, compared to at SD = 0.1 mm that promotes photothermal ablation. Dusting efficiency during short pulse Ho: YAG LL may be substantially improved by utilizing an optimal combination of v(fiber), SD, and frequency.
引用
收藏
页数:17
相关论文
共 50 条
[41]   Ureteroscopic High-Frequency Dusting Utilizing a 120-W Holmium Laser [J].
Tracey, James ;
Gagin, Galina ;
Morhardt, Duncan ;
Hollingsworth, John ;
Ghani, Khurshid R. .
JOURNAL OF ENDOUROLOGY, 2018, 32 (04) :290-295
[42]   High- and Low-Power Laser Lithotripsy Achieves Similar Results: A Systematic Review and Meta-Analysis of Available Clinical Series [J].
Ventimiglia, Eugenio ;
Pauchard, Felipe ;
Quadrini, Francesca ;
Sindhubodee, Sermsin ;
Kamkoum, Hatem ;
Jimenez Godinez, Alvaro ;
Doizi, Steeve ;
Traxer, Olivier .
JOURNAL OF ENDOUROLOGY, 2021, 35 (08) :1146-1152
[43]   How do we assess the efficacy of Ho:YAG low-power laser lithotripsy for the treatment of upper tract urinary stones? Introducing the Joules/mm3and laser activity concepts [J].
Ventimiglia, Eugenio ;
Pauchard, Felipe ;
Horta Gorgen, Antonio Rebello ;
Panthier, Frederic ;
Doizi, Steeve ;
Traxer, Olivier .
WORLD JOURNAL OF UROLOGY, 2021, 39 (03) :891-896
[44]   Evaluation of dusting versus basketing - can new technologies improve stone-free rates? [J].
Weiss, Brian ;
Shah, Ojas .
NATURE REVIEWS UROLOGY, 2016, 13 (12) :726-733
[45]  
Weisstein E., CIRCLE CIRCLE INTERS
[46]   Effect of Pulse Energy, Frequency and Length on Holmium: Yttrium-Aluminum-Garnet Laser Fragmentation Efficiency in Non-Floating Artificial Urinary Calculi [J].
Wezel, Felix ;
Haecker, Axel ;
Gross, Andreas J. ;
Michel, Maurice Stephan ;
Bach, Thorsten .
JOURNAL OF ENDOUROLOGY, 2010, 24 (07) :1135-1140
[47]   Dusting Efficiency of the Moses Holmium Laser: An Automated In Vitro Assessment [J].
Winship, Brenton ;
Wollin, Daniel ;
Carlos, Evan ;
Li, Jingqiu ;
Peters, Chloe ;
Simmons, W. Neal ;
Preminger, Glenn M. ;
Lipkin, Michael .
JOURNAL OF ENDOUROLOGY, 2018, 32 (12) :1131-1135
[48]   The Rise and Fall of High Temperatures During Ureteroscopic Holmium Laser Lithotripsy [J].
Winship, Brenton ;
Wollin, Daniel ;
Carlos, Evan ;
Peters, Chloe ;
Li, Jingqiu ;
Terry, Russell ;
Boydston, Kohldon ;
Preminger, Glenn M. ;
Lipkin, Michael E. .
JOURNAL OF ENDOUROLOGY, 2019, 33 (10) :794-799
[49]   Advanced laser scanning for highly-efficient ablation and ultrafast surface structuring: experiment and model [J].
Zemaitis, Andrius ;
Gaidys, Mantas ;
Brikas, Marijus ;
Gecys, Paulius ;
Raciukaitis, Gediminas ;
Gedvilas, Mindaugas .
SCIENTIFIC REPORTS, 2018, 8
[50]   Editorial Comment: Elucidating the Mechanism of Stone Dusting Requires a Fresh and Rigorous Approach in the New Era of Laser Lithotripsy [J].
Zhong, Pei ;
Lipkin, Michael E. ;
Preminger, Glenn M. .
JOURNAL OF ENDOUROLOGY, 2022, 36 (05) :686-687