Dissecting the Profile of Corneal Thickness With Keratoconus Progression Based on Anterior Segment Optical Coherence Tomography

被引:9
|
作者
Dong, Yanling [1 ,2 ]
Li, Dongfang [1 ,2 ]
Guo, Zhen [1 ,2 ]
Liu, Yang [3 ]
Lin, Ping [1 ,2 ]
Lv, Bin [3 ]
Lv, Chuanfeng [3 ]
Xie, Guotong [3 ,4 ,5 ]
Xie, Lixin [1 ,2 ]
机构
[1] Shandong First Med Univ, Qingdao Eye Hosp, Qingdao, Peoples R China
[2] Shandong First Med Univ, Inst Eye, Shandong Prov Key Lab Ophthalmol, State Key Lab Cultivat Base, Qingdao, Peoples R China
[3] Ping Technol Shenzhen Co Ltd, Shenzhen, Peoples R China
[4] Ping Hlth Cloud Co Ltd, Shenzhen, Peoples R China
[5] Ping Int Smart City Technol Co Ltd, Shenzhen, Peoples R China
关键词
keratoconus; corneal thickness; anterior segment optical coherence tomography; deep learning; segmentation;
D O I
10.3389/fnins.2021.804273
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
PurposeTo characterize the corneal and epithelial thickness at different stages of keratoconus (KC), using a deep learning based corneal segmentation algorithm for anterior segment optical coherence tomography (AS-OCT). MethodsAn AS-OCT dataset was constructed in this study with 1,430 images from 715 eyes, which included 118 normal eyes, 134 mild KC, 239 moderate KC, 153 severe KC, and 71 scarring KC. A deep learning based corneal segmentation algorithm was applied to isolate the epithelial and corneal tissues from the background. Based on the segmentation results, the thickness of epithelial and corneal tissues was automatically measured in the center 6 mm area. One-way ANOVA and linear regression were performed in 20 equally divided zones to explore the trend of the thickness changes at different locations with the KC progression. The 95% confidence intervals (CI) of epithelial thickness and corneal thickness in a specific zone were calculated to reveal the difference of thickness distribution among different groups. ResultsOur data showed that the deep learning based corneal segmentation algorithm can achieve accurate tissue segmentation and the error range of measured thickness was less than 4 mu m between our method and the results from clinical experts, which is approximately one image pixel. Statistical analyses revealed significant corneal thickness differences in all the divided zones (P < 0.05). The entire corneal thickness grew gradually thinner with the progression of the KC, and their trends were more pronounced around the pupil center with a slight shift toward the temporal and inferior side. Especially the epithelial thicknesses were thinner gradually from a normal eye to severe KC. Due to the formation of the corneal scarring, epithelial thickness had irregular fluctuations in the scarring KC. ConclusionOur study demonstrates that our deep learning method based on AS-OCT images could accurately delineate the corneal tissues and further successfully characterize the epithelial and corneal thickness changes at different stages of the KC progression.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Measurement of corneal and limbal epithelial thickness by anterior segment optical coherence tomography and in vivo confocal microscopy
    Le, Qihua
    Chen, Yan
    Yang, Yujing
    Xu, Jianjiang
    BMC OPHTHALMOLOGY, 2016, 16
  • [42] Age-related differences in corneal epithelial thickness measurements with anterior segment optical coherence tomography
    Kim, Bong Jun
    Ryu, Ik-Hee
    Kim, Sun Woong
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2016, 60 (05) : 357 - 364
  • [43] Comparison of central corneal thickness in corneal edema by ultrasound pachymetry, specular microscopy, and anterior segment optical coherence tomography
    Artuc, Tuncay
    Batur, Muhammed
    SAUDI JOURNAL OF OPHTHALMOLOGY, 2023, 37 (01) : 1 - 5
  • [44] New algorithm for corneal densitometry assessment based on anterior segment optical coherence tomography
    Yu Wang, Xiao
    Zhang, Tian Qiao
    Rahul Rachwani, Anil
    Blanco-Dominguez, Irene
    Rocha de Lossada, Carlos
    Manuel Adan-Civiera, Afredo
    Peraza-Nieves, Jorge
    EYE, 2022, 36 (08) : 1675 - 1680
  • [45] Investigation of the Sectorized Corneal Thickness of Eyes With Corneal Endothelial Dysfunction Using Anterior-Segment Optical Coherence Tomography
    Omoto, Takashi
    Kim, Minjae
    Goto, Hiroki
    Abe, Yuito
    Ono, Takashi
    Taketani, Yukako
    Toyono, Tetsuya
    Yoshida, Junko
    Usui, Tomohiko
    Yamagami, Satoru
    Aihara, Makoto
    Miyai, Takashi
    CORNEA, 2023, 42 (06) : 714 - 718
  • [46] New algorithm for corneal densitometry assessment based on anterior segment optical coherence tomography
    Xiao Yu Wang
    Tian Qiao Zhang
    Anil Rahul Rachwani
    Irene Blanco-Domínguez
    Carlos Rocha de Lossada
    Afredo Manuel Adán-Civiera
    Jorge Peraza-Nieves
    Eye, 2022, 36 : 1675 - 1680
  • [47] Utility of Anterior Segment Optical Coherence Tomography in the Management of Corneal Transplantation
    Takefumi Yamaguchi
    Jun Shimazaki
    Current Ophthalmology Reports, 2016, 4 (4) : 252 - 264
  • [48] Indications for intraoperative anterior segment optical coherence tomography in corneal surgery
    Stefan J. Lang
    Sonja Heinzelmann
    Daniel Böhringer
    Thomas Reinhard
    Philip Maier
    International Ophthalmology, 2020, 40 : 2617 - 2625
  • [49] Indications for intraoperative anterior segment optical coherence tomography in corneal surgery
    Lang, Stefan J.
    Heinzelmann, Sonja
    Boehringer, Daniel
    Reinhard, Thomas
    Maier, Philip
    INTERNATIONAL OPHTHALMOLOGY, 2020, 40 (10) : 2617 - 2625
  • [50] Anterior Segment Optical Coherence Tomography Findings in Corneal Blood Staining
    Mansoori, Tarannum
    Srirampur, Arjun
    JOURNAL OF CURRENT OPHTHALMOLOGY, 2021, 33 (01): : 95 - 95