Dissecting the Profile of Corneal Thickness With Keratoconus Progression Based on Anterior Segment Optical Coherence Tomography

被引:9
|
作者
Dong, Yanling [1 ,2 ]
Li, Dongfang [1 ,2 ]
Guo, Zhen [1 ,2 ]
Liu, Yang [3 ]
Lin, Ping [1 ,2 ]
Lv, Bin [3 ]
Lv, Chuanfeng [3 ]
Xie, Guotong [3 ,4 ,5 ]
Xie, Lixin [1 ,2 ]
机构
[1] Shandong First Med Univ, Qingdao Eye Hosp, Qingdao, Peoples R China
[2] Shandong First Med Univ, Inst Eye, Shandong Prov Key Lab Ophthalmol, State Key Lab Cultivat Base, Qingdao, Peoples R China
[3] Ping Technol Shenzhen Co Ltd, Shenzhen, Peoples R China
[4] Ping Hlth Cloud Co Ltd, Shenzhen, Peoples R China
[5] Ping Int Smart City Technol Co Ltd, Shenzhen, Peoples R China
关键词
keratoconus; corneal thickness; anterior segment optical coherence tomography; deep learning; segmentation;
D O I
10.3389/fnins.2021.804273
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
PurposeTo characterize the corneal and epithelial thickness at different stages of keratoconus (KC), using a deep learning based corneal segmentation algorithm for anterior segment optical coherence tomography (AS-OCT). MethodsAn AS-OCT dataset was constructed in this study with 1,430 images from 715 eyes, which included 118 normal eyes, 134 mild KC, 239 moderate KC, 153 severe KC, and 71 scarring KC. A deep learning based corneal segmentation algorithm was applied to isolate the epithelial and corneal tissues from the background. Based on the segmentation results, the thickness of epithelial and corneal tissues was automatically measured in the center 6 mm area. One-way ANOVA and linear regression were performed in 20 equally divided zones to explore the trend of the thickness changes at different locations with the KC progression. The 95% confidence intervals (CI) of epithelial thickness and corneal thickness in a specific zone were calculated to reveal the difference of thickness distribution among different groups. ResultsOur data showed that the deep learning based corneal segmentation algorithm can achieve accurate tissue segmentation and the error range of measured thickness was less than 4 mu m between our method and the results from clinical experts, which is approximately one image pixel. Statistical analyses revealed significant corneal thickness differences in all the divided zones (P < 0.05). The entire corneal thickness grew gradually thinner with the progression of the KC, and their trends were more pronounced around the pupil center with a slight shift toward the temporal and inferior side. Especially the epithelial thicknesses were thinner gradually from a normal eye to severe KC. Due to the formation of the corneal scarring, epithelial thickness had irregular fluctuations in the scarring KC. ConclusionOur study demonstrates that our deep learning method based on AS-OCT images could accurately delineate the corneal tissues and further successfully characterize the epithelial and corneal thickness changes at different stages of the KC progression.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Measurement of Corneal and Limbal Epithelial Thickness by In Vivo Confocal Microscopy and Anterior Segment Optical Coherence Tomography
    Le, Qihua
    Chen, Yan
    Yang, Yujing
    Xu, JianJiang
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [32] Comparison of central corneal thickness using anterior segment optical coherence tomography vs ultrasound pachymetry
    Kim, Hanna Y.
    Budenz, Donald L.
    Lee, Pak S.
    Feuer, William J.
    Barton, Keith
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2008, 145 (02) : 228 - 232
  • [33] Effects of topical antiglaucomatous medications on central corneal epithelial thickness by anterior segment optical coherence tomography
    Dogan, Emine
    Cakir, Burcin Koklu
    Aksoy, Nilgun Ozkan
    Celik, Erkan
    Erkorkmaz, Unal
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2020, 30 (06) : 1519 - 1524
  • [34] Evaluation of corneal epithelial thickness in glaucomatous patients using anterior-segment optical coherence tomography
    Montorio, Daniela
    Cennamo, Gilda
    Breve, Maria A.
    Fiore, Ugo
    Reibaldi, Michele
    Morra, Vincenzo Brescia
    Cennamo, Giovanni
    JOURNAL OF BIOPHOTONICS, 2020, 13 (01)
  • [35] Comparison of central corneal thickness measurements by visante anterior segment optical coherence tomography with ultrasound pachymetry
    Zhao, Paul S.
    Wong, Tien Yin
    Wong, Wan-Ling
    Saw, Seang-Mei
    Aung, Tin
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2007, 143 (06) : 1047 - 1049
  • [36] Corneal Thickness and Volume Measurements by Swept Source Anterior Segment Optical Coherence Tomography in Normal Subjects
    Fukuda, Reina
    Usui, Tomohiko
    Miyai, Takashi
    Mori, Yosai
    Miyata, Kazunori
    Amano, Shiro
    CURRENT EYE RESEARCH, 2013, 38 (05) : 531 - 536
  • [37] Age-related differences in corneal epithelial thickness measurements with anterior segment optical coherence tomography
    Bong Jun Kim
    Ik-Hee Ryu
    Sun Woong Kim
    Japanese Journal of Ophthalmology, 2016, 60 : 357 - 364
  • [38] Anterior segment optical coherence tomography and ultrasound biomicroscopy for measuring thickness of corneal and bulbar conjunctival tumours
    Lauwers, Noemie
    Janssens, Katleen
    Mertens, Michelle
    Mathysen, Danny
    Lammens, Martin
    de Keizer, Rob J. W.
    De Groot, Veva
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2022, 106 (06) : 760 - 764
  • [39] Age-Related Changes of Human Corneal Epithelial Thickness by Anterior Segment Optical Coherence Tomography
    Yang, Yujing
    Xu, JianJiang
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [40] Measurement of corneal and limbal epithelial thickness by anterior segment optical coherence tomography and in vivo confocal microscopy
    Qihua Le
    Yan Chen
    Yujing Yang
    Jianjiang Xu
    BMC Ophthalmology, 16