Dissecting the Profile of Corneal Thickness With Keratoconus Progression Based on Anterior Segment Optical Coherence Tomography

被引:9
|
作者
Dong, Yanling [1 ,2 ]
Li, Dongfang [1 ,2 ]
Guo, Zhen [1 ,2 ]
Liu, Yang [3 ]
Lin, Ping [1 ,2 ]
Lv, Bin [3 ]
Lv, Chuanfeng [3 ]
Xie, Guotong [3 ,4 ,5 ]
Xie, Lixin [1 ,2 ]
机构
[1] Shandong First Med Univ, Qingdao Eye Hosp, Qingdao, Peoples R China
[2] Shandong First Med Univ, Inst Eye, Shandong Prov Key Lab Ophthalmol, State Key Lab Cultivat Base, Qingdao, Peoples R China
[3] Ping Technol Shenzhen Co Ltd, Shenzhen, Peoples R China
[4] Ping Hlth Cloud Co Ltd, Shenzhen, Peoples R China
[5] Ping Int Smart City Technol Co Ltd, Shenzhen, Peoples R China
关键词
keratoconus; corneal thickness; anterior segment optical coherence tomography; deep learning; segmentation;
D O I
10.3389/fnins.2021.804273
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
PurposeTo characterize the corneal and epithelial thickness at different stages of keratoconus (KC), using a deep learning based corneal segmentation algorithm for anterior segment optical coherence tomography (AS-OCT). MethodsAn AS-OCT dataset was constructed in this study with 1,430 images from 715 eyes, which included 118 normal eyes, 134 mild KC, 239 moderate KC, 153 severe KC, and 71 scarring KC. A deep learning based corneal segmentation algorithm was applied to isolate the epithelial and corneal tissues from the background. Based on the segmentation results, the thickness of epithelial and corneal tissues was automatically measured in the center 6 mm area. One-way ANOVA and linear regression were performed in 20 equally divided zones to explore the trend of the thickness changes at different locations with the KC progression. The 95% confidence intervals (CI) of epithelial thickness and corneal thickness in a specific zone were calculated to reveal the difference of thickness distribution among different groups. ResultsOur data showed that the deep learning based corneal segmentation algorithm can achieve accurate tissue segmentation and the error range of measured thickness was less than 4 mu m between our method and the results from clinical experts, which is approximately one image pixel. Statistical analyses revealed significant corneal thickness differences in all the divided zones (P < 0.05). The entire corneal thickness grew gradually thinner with the progression of the KC, and their trends were more pronounced around the pupil center with a slight shift toward the temporal and inferior side. Especially the epithelial thicknesses were thinner gradually from a normal eye to severe KC. Due to the formation of the corneal scarring, epithelial thickness had irregular fluctuations in the scarring KC. ConclusionOur study demonstrates that our deep learning method based on AS-OCT images could accurately delineate the corneal tissues and further successfully characterize the epithelial and corneal thickness changes at different stages of the KC progression.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Risk factors and evaluation of keratoconus progression after penetrating keratoplasty with anterior segment optical coherence tomography
    Yoshida, Junko
    Toyono, Tetsuya
    Shirakawa, Rika
    Miyai, Takashi
    Usui, Tomohiko
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [22] Corneal stromal demarcation line after 4 protocols of corneal crosslinking in keratoconus determined with anterior segment optical coherence tomography
    Spadea, Leopoldo
    Di Genova, Lucia
    Tonti, Emanuele
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2018, 44 (05): : 596 - 602
  • [23] Corneal topographic analysis in patients with keratoconus using 3-dimensional anterior segment optical coherence tomography
    Nakagawa, Tomoya
    Maeda, Naoyuki
    Higashiura, Ritsuko
    Hori, Yuichi
    Inoue, Tomoyuki
    Nishida, Kohji
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (10): : 1871 - 1878
  • [24] Repeatability of anterior segment measurements by optical coherence tomography combined with Placido disk corneal topography in eyes with keratoconus
    Schiano-Lomoriello, Domenico
    Bono, Valeria
    Abicca, Irene
    Savini, Giacomo
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [25] Repeatability of anterior segment measurements by optical coherence tomography combined with Placido disk corneal topography in eyes with keratoconus
    Domenico Schiano-Lomoriello
    Valeria Bono
    Irene Abicca
    Giacomo Savini
    Scientific Reports, 10
  • [26] Corneal stromal demarcation line after 4 protocols of corneal crosslinking in keratoconus determined with anterior segment optical coherence tomography
    Torres-Netto, Emilio A.
    Randleman, J. Bradley
    Hafezi, Nikki L.
    Hafezi, Farhad
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2018, 44 (12): : 1535 - 1535
  • [27] Diagnosis of limbal stem cell deficiency based on corneal epithelial thickness measured on anterior segment optical coherence tomography
    Mehtani, Amit
    Agarwal, Mahesh Chandra
    Sharma, Sushant
    Chaudhary, Santosh
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2017, 65 (11) : 1120 - 1126
  • [28] Corneal epithelial thickness analysis of forme fruste keratoconus with optical coherence tomography
    Xiao-Long Yang
    Yun Wang
    Bao-Gen Luo
    Yue Xu
    Xiao-Feng Zhang
    International Journal of Ophthalmology, 2021, 14 (01) : 89 - 96
  • [29] Corneal epithelial thickness analysis of forme fruste keratoconus with optical coherence tomography
    Yang, Xiao-Long
    Wang, Yun
    Luo, Bao-Gen
    Xu, Yue
    Zhang, Xiao-Feng
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2021, 14 (01) : 89 - 96
  • [30] Tear meniscus particle analysis with anterior segment optical coherence tomography in keratoconus
    Seyyar, Sevim Ayca
    Buyukbayram, Saban
    Soysal, Gizem Gurbostan
    Ayla, Serhat
    Dogan, Levent
    Tokuc, Ecem Onder
    Mercanli, Murat
    Mete, Alper
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2024, 72 (08) : 1136 - 1141