Contrast-enhanced ultrasonography in the evaluation of incidental focal liver lesions: A cost-effectiveness analysis

被引:30
作者
Smajerova, Miriama [1 ,2 ]
Petrasova, Hana [1 ,2 ]
Little, Jirina [1 ,2 ]
Ovesna, Petra [3 ]
Andrasina, Tomas [1 ,2 ]
Valek, Vlastimil [1 ,2 ]
Nemcova, Eva [1 ,2 ]
Miklosova, Barbora [1 ,2 ]
机构
[1] Univ Hosp Brno, Dept Radiol, Jihlavska 20, Brno 62500, Czech Republic
[2] Masaryk Univ, Fac Med, Brno 62500, Czech Republic
[3] Masaryk Univ, Inst Biostat & Anal, Brno 62500, Czech Republic
关键词
Contrast-enhanced ultrasonography; Focal liver lesion; Computed tomography; Magnetic resonance imaging; Economic analysis; CLINICAL-PRACTICE; ULTRASOUND CEUS; MULTICENTER; CT; SONOGRAPHY; GUIDELINES; DIAGNOSIS; BENIGN; MRI;
D O I
10.3748/wjg.v22.i38.8605
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
AIM To determine whether contrast-enhanced ultrasonography (CEUS) as the first-line method is more cost-effective in evaluating incidentally discovered focal liver lesions (FLLs) than is computed tomography (CT) and magnetic resonance imaging (MRI). METHODS Between 2010 and 2015, our prospective study enrolled 459 patients with incidentally found FLLs. The biological nature of FLLs was assessed by CEUS in all patients. CT or MRI examinations were added in unclear cases. The sensitivity and specificity of CEUS were calculated. The total costs of CEUS examinations and of the added examinations performed in inconclusive cases were calculated. Afterwards, the theoretical expenses for evaluating incidentally discovered FLLs using CT or MRI as the first-line method were calculated. The results were compared. RESULTS The total cost of the diagnostic process using CEUS for all enrolled patients with FLLs was 75884 USD. When the expenses for additional CT and MRI examinations performed in inconclusive cases were added, the total cost was 90540 US dollar (USD). If all patients had been examined by CT or MR as the first-line method, the costs would have been 78897 USD or 384235 USD, respectively. The difference between the cost of CT and CEUS was 3013 USD (4%) and that between MRI and CEUS was 308352 USD (406.3%). We correctly described 97.06% of benign or malignant lesions, with 96.99% sensitivity and 97.09% specificity. Positive predictive value was 94.16% and negative predictive value was 98.52%. In cases with 4 and more lesions, malignancy is significantly more frequent and inconclusive findings significantly less frequent (P < 0.001). CONCLUSION While the costs of CEUS and CT in evaluating FLLs are comparable, CEUS examination is far more cost-effective in comparison to MRI.
引用
收藏
页码:8605 / 8614
页数:10
相关论文
共 26 条
[1]   Guidelines for the use of contrast agents in ultrasound [J].
Albrecht, T ;
Blomley, M ;
Bolondi, L ;
Claudon, M ;
Correas, JM ;
Cosgrove, D ;
Greiner, L ;
Jäger, K ;
de Jong, N ;
Leen, E ;
Lencioni, R ;
Lindsell, D ;
Martegani, A ;
Solbiati, L ;
Thorelius, L ;
Tranquart, F ;
Weskott, HP ;
Whittingham, T .
ULTRASCHALL IN DER MEDIZIN, 2004, 25 (04) :249-256
[2]   Characterization of liver lesions by real-time contrast-enhanced ultrasonography [J].
Celli, Natascia ;
Gaiani, Stefano ;
Piscaglia, Fabio ;
Zironi, Gianni ;
Camaggi, Valerla ;
Leoni, Simona ;
Righini, Roberto ;
Bolondi, Luigi .
EUROPEAN JOURNAL OF GASTROENTEROLOGY & HEPATOLOGY, 2007, 19 (01) :3-14
[3]   Guidelines and good clinical practice recommendations for contrast enhanced ultrasound (CEUS) -: Update 2008 [J].
Claudon, M. ;
Cosgrove, D. ;
Albrecht, T. ;
Bolondi, L. ;
Bosio, M. ;
Calliada, F. ;
Correas, J. -M. ;
Darge, K. ;
Dietrich, C. ;
D'Onofrio, M. ;
Evans, D. H. ;
Filice, C. ;
Greiner, L. ;
Jaeger, K. ;
de Jong, N. ;
Leen, E. ;
Lencioni, R. ;
Lindsell, D. ;
Martegani, A. ;
Meairs, S. ;
Nolsoe, C. ;
Piscaglia, F. ;
Ricci, P. ;
Seidel, G. ;
Skjoldbye, B. ;
Solbiati, L. ;
Thorelius, L. ;
Tranquart, F. ;
Weskott, H. P. ;
Whittingham, T. .
ULTRASCHALL IN DER MEDIZIN, 2008, 29 (01) :28-44
[4]   GUIDELINES AND GOOD CLINICAL PRACTICE RECOMMENDATIONS FOR CONTRAST ENHANCED ULTRASOUND (CEUS) IN THE LIVER - UPDATE 2012 A WFUMB-EFSUMB INITIATIVE IN COOPERATION WITH REPRESENTATIVES OF AFSUMB, AIUM, ASUM, FLAUS AND ICUS [J].
Claudon, Michel ;
Dietrich, Christoph F. ;
Choi, Byung Ihn ;
Cosgrove, David O. ;
Kudo, Masatoshi ;
Nolsoe, Christian P. ;
Piscaglia, Fabio ;
Wilson, Stephanie R. ;
Barr, Richard G. ;
Chammas, Maria C. ;
Chaubal, Nitin G. ;
Chen, Min-Hua ;
Clevert, Dirk Andre ;
Correas, Jean Michel ;
Ding, Hong ;
Forsberg, Flemming ;
Fowlkes, J. Brian ;
Gibson, Robert N. ;
Goldberg, Barry B. ;
Lassau, Nathalie ;
Leen, Edward L. S. ;
Mattrey, Robert F. ;
Moriyasu, Fuminori ;
Solbiati, Luigi ;
Weskott, Hans-Peter ;
Xu, Hui-Xiong .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2013, 39 (02) :187-210
[5]  
Czech National Bank, EXCHANGE
[6]   Contrast-enhanced ultrasonography in the characterization of benign focal liver lesions: activity-based cost analysis [J].
Faccioli, N. ;
D'Onofrio, M. ;
Comai, A. ;
Cugini, C. .
RADIOLOGIA MEDICA, 2007, 112 (06) :810-820
[7]   Contrast-Enhanced Ultrasound for the Characterization of Incidental Liver Lesions - An Economical Evaluation in Comparison with Multi-Phase Computed Tomography [J].
Giesel, F. L. ;
Delorme, S. ;
Sibbel, R. ;
Kauczor, H. -U. ;
Krix, M. .
ULTRASCHALL IN DER MEDIZIN, 2009, 30 (03) :259-268
[8]   Diagnosis of hepatocellular carcinoma [J].
Gomaa, Asmaa I. ;
Khan, Shahid A. ;
Leen, Edward L. S. ;
Waked, Imam ;
Taylor-Robinson, Simon D. .
WORLD JOURNAL OF GASTROENTEROLOGY, 2009, 15 (11) :1301-1314
[9]   Technology overview: SonoVue (Bracco, Milan) [J].
Greis, C .
EUROPEAN RADIOLOGY, 2004, 14 :P11-P15
[10]   Liver tumor characterization: Comparison between liver-specific gadoxetic acid disodium-enhanced MRI and biphasic CT - A multicenter trial [J].
Halavaara, J ;
Breuer, J ;
Ayuso, C ;
Balzer, T ;
Bellin, MF ;
Blomqvist, L ;
Carter, R ;
Grazioli, L ;
Hammerstingl, R ;
Huppertz, A ;
Jung, G ;
Krause, D ;
Laghi, A ;
Leen, E ;
Lupatelli, L ;
Marsili, L ;
Martin, J ;
Pretorius, ES ;
Reinhold, C ;
Stiskal, M ;
Stolpen, AH .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2006, 30 (03) :345-354