Computational area measurement of orbital floor fractures: Reliability, accuracy and rapidity

被引:17
作者
Schouman, Thomas [1 ,2 ]
Courvoisier, Delphine S. [2 ,3 ]
Imholz, Benoit [1 ,2 ]
Van Issum, Christopher [2 ,4 ]
Scolozzi, Paolo [1 ,2 ]
机构
[1] Univ Hosp, Dept Surg, Serv Oral & Maxillofacial Surg, CH-1211 Geneva, Switzerland
[2] Fac Med Geneva, CH-1211 Geneva, Switzerland
[3] Univ Hosp, Biostatistician Serv Clin Epidemiol, CH-1211 Geneva, Switzerland
[4] Univ Hosp, Serv Ophthalmol, CH-1211 Geneva, Switzerland
关键词
Orbit; Fracture; Three-dimensional imaging; CT; ISOLATED BLOWOUT FRACTURES; COMPUTED-TOMOGRAPHY; RECONSTRUCTION;
D O I
10.1016/j.ejrad.2011.06.024
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To evaluate the reliability, accuracy and rapidity of a specific computational method for assessing the orbital floor fracture area on a CT scan. Method: A computer assessment of the area of the fracture, as well as that of the total orbital floor, was determined on CT scans taken from ten patients. The ratio of the fracture's area to the orbital floor area was also calculated. The test-retest precision of measurement calculations was estimated using the Intraclass Correlation Coefficient (ICC) and Dahlberg's formula to assess the agreement across observers and across measures. The time needed for the complete assessment was also evaluated. Results: The Intraclass Correlation Coefficient across observers was 0.92 [0.85;0.96], and the precision of the measures across observers was 4.9%, according to Dahlberg's formula. The mean time needed to make one measurement was 2 min and 39 s (range, 1 min and 32 s to 4 min and 37 s). Conclusion: This study demonstrated that (1) the area of the orbital floor fracture can be rapidly and reliably assessed by using a specific computer system directly on CT scan images; (2) this method has the potential of being routinely used to standardize the post-traumatic evaluation of orbital fractures. (C) 2011 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:2251 / 2254
页数:4
相关论文
共 15 条
[1]   Orbital floor reconstruction with an alloplastic resorbable polydioxanone sheet [J].
Baumann, A ;
Burggasser, G ;
Gauss, N ;
Ewers, R .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2002, 31 (04) :367-373
[2]  
Bland J.M., CAN I DECIDE SAMPLE
[3]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]   Clinical recommendations for repair of isolated orbital floor fractures - An evidence-based analysis [J].
Burnstine, MA .
OPHTHALMOLOGY, 2002, 109 (07) :1207-1210
[5]   Comprehensive management of orbital fractures [J].
Cole, Patrick ;
Boyd, Vincent ;
Banerji, Soumo ;
Hollier, Larry H., Jr. .
PLASTIC AND RECONSTRUCTIVE SURGERY, 2007, 120 (07) :57S-63S
[6]   Quantitative analysis of the orbital floor defect after zygoma fracture repair [J].
Czerwinski, Marcin ;
Izadpanah, Ali ;
Ma, Stephanie ;
Chankowsky, Jeffrey ;
Williams, H. Bruce .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2008, 66 (09) :1869-1874
[8]   Analysis of Orbital Bone Fractures: A 12-Year Study of 391 Patients [J].
Hwang, Kun ;
You, Sun Hye ;
Sohn, In Ah .
JOURNAL OF CRANIOFACIAL SURGERY, 2009, 20 (04) :1218-1223
[9]   Reconstruction of orbital wall defects:: critical review of 72 patients [J].
Jaquiery, C. ;
Aeppli, C. ;
Cornelius, P. ;
Palmowsky, A. ;
Kunz, C. ;
Hammer, B. .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2007, 36 (03) :193-199
[10]  
Jin HR, 2000, J ORAL MAXIL SURG, V58, P617